Revising organic vapour respirator cartridge change schedule: a case study of a paint plant in Iran.

Ali Karimi1, Mehdi Jahangiri, Forough Zare Derisi, Mohammad Amin Nourozi.   

Abstract

After having revised the change schedule for organic vapour respirator cartridges in a paint plant in Iran, we established that it did not provide adequate protection against organic vapours at some workplaces and needed shortening from (48 to 72) h to 4 h. The revision also showed that relying on odour thresholds as the primary means to determine the time to change a chemical cartridge was not effective and that the National Institute for Occupational Safety and Health (NIOSH) MultiVapor service life software program could be applied to develop cartridge change schedules adjusted to specific workplaces.

Mesh:

Substances:

Year:  2013        PMID: 23585165     DOI: 10.2478/10004-1254-64-2013-2256

Source DB:  PubMed          Journal:  Arh Hig Rada Toksikol        ISSN: 0004-1254            Impact factor:   1.948