Literature DB >> 23584227

A photoelectrochemical sensor based on nickel hydroxyl-oxide modified n-silicon electrode for hydrogen peroxide detection in an alkaline solution.

Huaixiang Li1, Wenlong Hao, Jinchao Hu, Hongyan Wu.   

Abstract

A novel photoelectrochemical hydrogen peroxide (H2O2) sensor was constructed with platinum (Pt) and nickel hydroxyl-oxide (NiOOH) double layers modified n-silicon electrode (NiOOH/Pt/n-n(+)-Si). About 40nm Pt layer and about 100nm Ni layer were successively coated on the front surface of n-n(+)-Si (111) wafers by vacuum evaporating. A stable layer of NiOOH was formed through oxidation of the Ni layer on the coated silicon wafer by the electrochemical method. The surface of modified electrode was characterized by scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). The NiOOH/Pt/n-n(+)-Si electrode has been used for determination of H2O2 with a two-electrode cell in the absence of reference electrode by photocurrent measurement at a zero bias. The photoelectrochemical sensor showed a good linear response to H2O2 concentrations in a range from 1.0×10(-5) to 6×10(-5)M with a determination limit (S/N=3) of 2.2μM. The NiOOH/Pt/n-n(+)-Si electrode exhibited excellent reproducibility and stability. Particularly, the facile measurement requirements made this novel modified electrode promising for the development of outdoor H2O2 sensors.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23584227     DOI: 10.1016/j.bios.2013.03.028

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  Carbon-dot wrapped ZnO nanoparticle-based photoelectrochemical sensor for selective monitoring of H2O2 released from cancer cells.

Authors:  Faria Khan; Naeem Akhtar; Nasir Jalal; Irshad Hussain; Rafal Szmigielski; Muhammad Qasim Hayat; Hafiz B Ahmad; Waleed A El-Said; Minghui Yang; Hussnain Ahmed Janjua
Journal:  Mikrochim Acta       Date:  2019-01-25       Impact factor: 5.833

Review 2.  Metal oxide nanoparticles in electrochemical sensing and biosensing: a review.

Authors:  Jaise Mariya George; Arun Antony; Beena Mathew
Journal:  Mikrochim Acta       Date:  2018-07-04       Impact factor: 5.833

3.  Cadmium Sulphide-Reduced Graphene Oxide-Modified Photoelectrode-Based Photoelectrochemical Sensing Platform for Copper(II) Ions.

Authors:  I Ibrahim; H N Lim; N M Huang; A Pandikumar
Journal:  PLoS One       Date:  2016-05-13       Impact factor: 3.240

4.  Controlling the Size and Pattern Pitch of Ni(OH)2 Nanoclusters Using Dip-Pen Nanolithography to Improve Water Oxidation.

Authors:  Zorik Shamish; Moshe Zohar; Dror Shamir; Ariela Burg
Journal:  Molecules       Date:  2020-06-26       Impact factor: 4.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.