Literature DB >> 23582363

Ciliary sulcus diameters at different anterior chamber depths in highly myopic eyes.

Jian Gao1, Rong-Feng Liao, Ning Li.   

Abstract

PURPOSE: To determine the correlation between white-to-white (WTW) diameters and horizontal ciliary sulcus diameters at different anterior chamber depths (ACDs) in highly myopic eyes.
SETTING: First Affiliated Hospital of Anhui Medical University, Hefei, China.
DESIGN: Cross-sectional observational study.
METHODS: Highly myopic eyes were divided into a shallow ACD group (2.8 to 3.2 mm), medium ACD group (3.2 to 3.4 mm), and deep ACD group (>3.4 mm). Ciliary sulcus diameters were measured by full-scale 50 MHz ultrasound biomicroscopy.
RESULTS: In the shallow ACD group, linear regression showed that horizontal sulcus diameters were a significant predictor of WTW diameters (P<.001). The difference between them was greater than 0.50 mm in 13.1% of eyes. In the medium ACD group, linear regression showed horizontal sulcus diameters were a significant predictor of WTW diameters (P<.001). The difference between them was greater than 0.50 mm in 25.7% of eyes and greater than 1.0 mm in 2.8% of eyes. In the deep ACD group, linear regression did not show that horizontal sulcus diameters were a significant predictor of WTW diameters (P=.126). The difference between them was greater than 0.50 mm in 31.6% of eyes and greater than 1.0 mm in 5.3% of eyes. In all eyes, vertical diameters were greater than horizontal diameters.
CONCLUSIONS: The WTW technique was inaccurate at predicting the horizontal diameter of the ciliary sulcus, and predictive errors increased with increasing ACDs. The posterior chambers were not perfectly circular, with vertical diameters being greater than horizontal diameters. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.
Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Mesh:

Year:  2013        PMID: 23582363     DOI: 10.1016/j.jcrs.2013.01.040

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  6 in total

1.  Vertical implantable collamer lens (ICL) rotation for the management of high vault due to lens oversizing.

Authors:  Francesco Matarazzo; Alexander Clifford Day; Luis Fernandez-Vega Cueto; Vincenzo Maurino
Journal:  Int Ophthalmol       Date:  2017-11-01       Impact factor: 2.031

2.  Angle-to-angle and spur-to-spur distance analysis with high-resolution optical coherence tomography.

Authors:  Robert Montés-Micó; Pedro Tañá-Rivero; Salvador Aguilar-Córcoles; María Ruiz-Santos; María Dolores Rodríguez-Carrillo; Ramón Ruiz-Mesa
Journal:  Eye Vis (Lond)       Date:  2020-08-16

3.  Effects of optical diameter of intraocular lenses with intrascleral fixation on higher-order aberrations.

Authors:  Daisuke Kunita; Makoto Inoue; Yuji Itoh; Naoko Matsuki; Toshiyuki Nagamoto; Akito Hirakata
Journal:  BMC Ophthalmol       Date:  2017-06-02       Impact factor: 2.209

4.  Correlation between intraoperative and postoperative vaulting of the EVO implantable Collamer lens: a retrospective study of real-time observations of vaulting using the RESCAN 700 system.

Authors:  Nian Guan; Xiao-Nong Zhang; Wan-Jun Zhang
Journal:  BMC Ophthalmol       Date:  2022-01-03       Impact factor: 2.209

5.  A prediction model for sulcus-to-sulcus diameter in myopic eyes: a 1466-sample retrospective study.

Authors:  Qiu-Jian Zhu; Wei-Jian Zhu; Wen-Jing Chen; Lie Ma; You Yuan
Journal:  BMC Ophthalmol       Date:  2022-07-16       Impact factor: 2.086

6.  Iridociliary cysts do not impact on posterior phakic intraocular lens implantation for high myopia correction: A prospective cohort study in 1569 eyes.

Authors:  Xi Zhang; Xun Chen; Xiaoying Wang; Xingtao Zhou
Journal:  PLoS One       Date:  2018-04-26       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.