Jian Gao1, Rong-Feng Liao, Ning Li. 1. Department of Ophthalmology, First Affiliated Hospital of Anhui Medical University, Hefei, China.
Abstract
PURPOSE: To determine the correlation between white-to-white (WTW) diameters and horizontal ciliary sulcus diameters at different anterior chamber depths (ACDs) in highly myopic eyes. SETTING: First Affiliated Hospital of Anhui Medical University, Hefei, China. DESIGN: Cross-sectional observational study. METHODS: Highly myopic eyes were divided into a shallow ACD group (2.8 to 3.2 mm), medium ACD group (3.2 to 3.4 mm), and deep ACD group (>3.4 mm). Ciliary sulcus diameters were measured by full-scale 50 MHz ultrasound biomicroscopy. RESULTS: In the shallow ACD group, linear regression showed that horizontal sulcus diameters were a significant predictor of WTW diameters (P<.001). The difference between them was greater than 0.50 mm in 13.1% of eyes. In the medium ACD group, linear regression showed horizontal sulcus diameters were a significant predictor of WTW diameters (P<.001). The difference between them was greater than 0.50 mm in 25.7% of eyes and greater than 1.0 mm in 2.8% of eyes. In the deep ACD group, linear regression did not show that horizontal sulcus diameters were a significant predictor of WTW diameters (P=.126). The difference between them was greater than 0.50 mm in 31.6% of eyes and greater than 1.0 mm in 5.3% of eyes. In all eyes, vertical diameters were greater than horizontal diameters. CONCLUSIONS: The WTW technique was inaccurate at predicting the horizontal diameter of the ciliary sulcus, and predictive errors increased with increasing ACDs. The posterior chambers were not perfectly circular, with vertical diameters being greater than horizontal diameters. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.
PURPOSE: To determine the correlation between white-to-white (WTW) diameters and horizontal ciliary sulcus diameters at different anterior chamber depths (ACDs) in highly myopic eyes. SETTING: First Affiliated Hospital of Anhui Medical University, Hefei, China. DESIGN: Cross-sectional observational study. METHODS: Highly myopic eyes were divided into a shallow ACD group (2.8 to 3.2 mm), medium ACD group (3.2 to 3.4 mm), and deep ACD group (>3.4 mm). Ciliary sulcus diameters were measured by full-scale 50 MHz ultrasound biomicroscopy. RESULTS: In the shallow ACD group, linear regression showed that horizontal sulcus diameters were a significant predictor of WTW diameters (P<.001). The difference between them was greater than 0.50 mm in 13.1% of eyes. In the medium ACD group, linear regression showed horizontal sulcus diameters were a significant predictor of WTW diameters (P<.001). The difference between them was greater than 0.50 mm in 25.7% of eyes and greater than 1.0 mm in 2.8% of eyes. In the deep ACD group, linear regression did not show that horizontal sulcus diameters were a significant predictor of WTW diameters (P=.126). The difference between them was greater than 0.50 mm in 31.6% of eyes and greater than 1.0 mm in 5.3% of eyes. In all eyes, vertical diameters were greater than horizontal diameters. CONCLUSIONS: The WTW technique was inaccurate at predicting the horizontal diameter of the ciliary sulcus, and predictive errors increased with increasing ACDs. The posterior chambers were not perfectly circular, with vertical diameters being greater than horizontal diameters. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.
Authors: Francesco Matarazzo; Alexander Clifford Day; Luis Fernandez-Vega Cueto; Vincenzo Maurino Journal: Int Ophthalmol Date: 2017-11-01 Impact factor: 2.031
Authors: Robert Montés-Micó; Pedro Tañá-Rivero; Salvador Aguilar-Córcoles; María Ruiz-Santos; María Dolores Rodríguez-Carrillo; Ramón Ruiz-Mesa Journal: Eye Vis (Lond) Date: 2020-08-16