Literature DB >> 23579478

Test-retest reliability of biodex system 4 pro for isometric ankle-eversion and -inversion measurement.

Gediminas Tankevicius1, Doanata Lankaite, Aleksandras Krisciunas.   

Abstract

CONTEXT: The lack of knowledge about isometric ankle testing indicates the need for research in this area.
OBJECTIVE: to assess test-retest reliability and to determine the optimal position for isometric ankle-eversion and -inversion testing.
DESIGN: Test-retest reliability study. Isometric ankle eversion and inversion were assessed in 3 different dynamometer foot-plate positions: 0°, 7°, and 14° of inversion. Two maximal repetitions were performed at each angle. Both limbs were tested (40 ankles in total). The test was performed 2 times with a period of 7 d between the tests.
SETTING: University hospital. PARTICIPANTS: The study was carried out on 20 healthy athletes with no history of ankle sprains. MAIN OUTCOME MEASURES: Reliability was assessed using intraclass correlation coefficient (ICC2,1); minimal detectable change (MDC) was calculated using a 95% confidence interval. Paired t test was used to measure statistically significant changes, and P <.05 was considered statistically significant.
RESULTS: Eversion and inversion peak torques showed high ICCs in all 3 angles (ICC values .87-.96, MDC values 3.09-6.81 Nm). Eversion peak torque was the smallest when testing at the 0° angle and gradually increased, reaching maximum values at 14° angle. The increase of eversion peak torque was statistically significant at 7 ° and 14° of inversion. Inversion peak torque showed an opposite pattern-it was the smallest when measured at the 14° angle and increased at the other 2 angles; statistically significant changes were seen only between measures taken at 0° and 14°.
CONCLUSIONS: Isometric eversion and inversion testing using the Biodex 4 Pro system is a reliable method. The authors suggest that the angle of 7° of inversion is the best for isometric eversion and inversion testing.

Entities:  

Mesh:

Year:  2013        PMID: 23579478     DOI: 10.1123/jsr.22.3.212

Source DB:  PubMed          Journal:  J Sport Rehabil        ISSN: 1056-6716            Impact factor:   1.931


  4 in total

1.  RELIABILITY, COMPARABILITY, AND VALIDITY OF FOOT INVERSION AND EVERSION STRENGTH MEASUREMENTS USING A HAND-HELD DYNAMOMETER.

Authors:  Martin Alfuth; Magali Murielle Hahm
Journal:  Int J Sports Phys Ther       Date:  2016-02

2.  Ankle strength, muscle size, and adipose content following unilateral tibiotalar arthrodesis.

Authors:  Jennifer A Nichols; Kenneth Bo Foreman; Alexej Barg; Charles L Saltzman; Andrew E Anderson
Journal:  J Orthop Res       Date:  2019-03-28       Impact factor: 3.494

3.  A Novel Anatomic Reconstruction for Posterior Tibialis Tendon in Treatment of Flexible Adult-Acquired Flatfoot Deformity.

Authors:  Yong Hu; Yifan Wang; Zheng Huang; Zhengxun Li; Wenpeng Xu; Dongsheng Zhou; Ning Zhang
Journal:  Orthop Surg       Date:  2022-06-10       Impact factor: 2.279

4.  Effects of Whole-Body Vibration and Balance Training on Female Athletes with Chronic Ankle Instability.

Authors:  Wen-Dien Chang; Shuya Chen; Yung-An Tsou
Journal:  J Clin Med       Date:  2021-05-28       Impact factor: 4.241

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.