| Literature DB >> 23576858 |
Andrea Petznick1, Annabel Chew, Reece C Hall, Cordelia Ml Chan, Mohamad Rosman, Donald Tan, Louis Tong, Jodhbir S Mehta.
Abstract
PURPOSE: To evaluate longitudinal changes in corneal sensitivity, tear function, and corneal staining in patients who underwent laser in situ keratomileusis (LASIK) using two different femtosecond lasers.Entities:
Keywords: Schirmer’s; corneal sensitivity; corneal staining; femtosecond laser; tear film break-up time
Year: 2013 PMID: 23576858 PMCID: PMC3616690 DOI: 10.2147/OPTH.S42266
Source DB: PubMed Journal: Clin Ophthalmol ISSN: 1177-5467
Patient data and preoperative ocular parameters
| Flap creation | Mean age, range (years) | Sex (n) | Eyes (n) | Mean SER ± SD (D) | Mean K ± SD (D) | |
|---|---|---|---|---|---|---|
|
| ||||||
| Male | Female | |||||
| VisuMax | 28.8, 21–39 | 20 | 25 | 45 | −4.94 ± 2.08 | 44.16 ± 1.81 |
| IntraLase™ | 45 | −4.91 ± 2.09 | 44.02 ± 1.61 | |||
| – | – | – | – | 0.94 | 0.26 | |
Notes: VisuMax (Carl Zeiss Meditec, Jena, Germany) and IntraLase™ (Abbott Medical Optics Inc, Santa Ana, CA, USA).
Abbreviations: SER, spherical equivalent refraction; SD, standard deviation; K, keratometry; D, diopter.
Changes over time in corneal sensitivity following VisuMax or IntraLase™ LASIK
| Preop | 1 month | 3 months | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
| |||||||||||||
| Level of myopia | Flap creation | Mean (cm) | 95% CI | Mean (cm) | 95% CI | Change to preop (%) | Mean (cm) | 95% CI | Change to preop (%) | ||||||
| ≥−6.00 D | VisuMax | 5.9 | 4.9 | 6.9 | 0.434 | 3.5 | 2.4 | 4.6 | −40.7 | 0.335 | 4.0 | 2.8 | 5.1 | −32.3 | 0.468 |
| IntraLase | 5.7 | 4.5 | 7.0 | 3.8 | 2.4 | 5.1 | −34.3 | 3.2 | 1.8 | 4.6 | −43.6 | ||||
| Eyes (n) | 24 | 21 | 18 | ||||||||||||
| <−6.00 D | VisuMax | 5.9 | 5.5 | 6.3 | 0.086 | 5.3 | 4.9 | 5.8 | −9.7 | 0.095 | 5.2 | 4.7 | 5.6 | −12.5 | 0.107 |
| IntraLase | 5.8 | 5.3 | 6.3 | 4.8 | 4.3 | 5.3 | −17.1 | 4.9 | 4.4 | 5.4 | −14.8 | ||||
| Eyes (n) | 63 | 55 | 54 | ||||||||||||
Notes: Estimated mean of corneal sensitivity, lower and upper bound of 95% confidence interval. VisuMax (Carl Zeiss Meditec, Jena, Germany) and IntraLase™ (Abbott Medical Optics Inc, Santa Ana, CA, USA).
Abbreviations: LASIK, laser in situ keratomileusis; CI, confidence interval.
Reduction of TBUT following VisuMax and IntraLase™ LASIK
| Preop | 1 week | 1 month | 3 months | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
| |||||||||||||||||
| Level of myopia | Flap creation | Mean (sec) | 95% CI | Mean (sec) | 95% CI | Change to preop (%) | Mean (sec) | 95% CI | Change to preop (%) | Mean (sec) | 95% CI | Change to preop (%) | ||||||||
| ≥−6.00 D | VisuMax | 10.1 | 8.8 | 11.4 | 0.318 | 8.3 | 5.8 | 10.9 | −17.4 | – | 8.6 | 6.9 | 10.3 | −14.8 | – | 10.2 | 8.6 | 11.9 | +1.4 | – |
| IntraLase | 9.5 | 7.9 | 11.1 | 5.3 | 2.3 | 8.3 | −44.1 | 7.5 | 5.6 | 9.4 | −20.8 | 8.2 | 5.9 | 10.4 | −14.2 | |||||
| Eyes (n) | 25 | 5 | 13 | 13 | ||||||||||||||||
| <−6.00 D | VisuMax | 10.5 | 9.1 | 11.9 | 0.377 | 8.8 | 6.5 | 11.0 | −16.6 | 0.211 | 9.3 | 7.5 | 11.1 | −11.6 | 0.981 | 8.8 | 7.0 | 10.6 | −16.8 | 0.892 |
| IntraLase | 10.2 | 8.9 | 11.4 | 7.5 | 5.9 | 9.2 | −25.9 | 8.4 | 6.9 | 9.8 | −17.7 | 8.0 | 6.6 | 9.5 | −21.0 | |||||
| Eyes (n) | 62 | 19 | 33 | 36 | ||||||||||||||||
Notes: Estimated mean of TBUT, lower and upper bound of 95% confidence interval. A statistical comparison using the linear mixed model adjusted for surgeon, age, and gender could not be performed for a level of myopia greater than −6.00 D due to small sample size.
Abbreviations: TBUT, tear film break up time; LASIK, laser in situ keratomileusis; CI, confidence interval; D, diopter.
Reduction of Schirmer’s value following VisuMax and IntraLase™ LASIK
| Preop | 1 week | 1 month | 3 months | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
| |||||||||||||||||
| Level of myopia | Flap creation | Mean (cm) | 95% CI | Mean (cm) | 95% CI | Change to preop (%) | Mean (cm) | 95% CI | Change to preop (%) | Mean (cm) | 95% CI | Change to preop (%) | ||||||||
| ≥−6.00 D | VisuMax | 11.3 | 7.6 | 15.0 | 0.577 | 8.8 | 5.1 | 12.5 | −22.1 | 0.542 | 10.4 | 6.6 | 14.2 | −7.8 | 0.464 | 10.1 | 6.1 | 14.1 | −10.5 | 0.447 |
| IntraLase | 11.7 | 6.6 | 16.9 | 9.2 | 3.9 | 14.5 | −21.6 | 12.4 | 7.1 | 17.7 | +5.8 | 9.4 | 3.9 | 14.8 | −20.2 | |||||
| Eyes (n) | 24 | 22 | 21 | 18 | ||||||||||||||||
| <−6.00 D | VisuMax | 15.2 | 12.2 | 18.3 | 0.316 | 12.4 | 9.4 | 15.3 | −18.8 | 0.233 | 12.8 | 9.7 | 15.9 | −16.0 | 0.956 | 12.7 | 9.5 | 15.9 | −16.3 | 0.069 |
| IntraLase | 13.7 | 11.0 | 16.4 | 10.7 | 8.0 | 13.4 | −21.9 | 12.4 | 9.7 | 15.2 | −9.0 | 13.7 | 10.9 | 16.6 | +0.4 | |||||
| Eyes (n) | 62 | 62 | 57 | 51 | ||||||||||||||||
Notes: Estimated mean of Schirmer’s, lower and upper bound of 95% confidence interval. VisuMax (Carl Zeiss Meditec, Jena, Germany) and IntraLase™ (Abbott Medical Optics Inc, Santa Ana, CA, USA).
Abbreviations: LASIK, laser in situ keratomileusis; CI, confidence interval; D, diopter.
Changes over time in corneal fluorescein staining and incidence rates following VisuMax or IntraLase™ LASIK
| Preop | 1 week | 1 month | 3 months | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
| ||||||||||
| Level of myopia | Flap creation | Mean | SE | Incidence rate (%) | Mean | SE | Incidence rate (%) | Mean | SE | Incidence rate (%) | Mean | SE | Incidence rate (%) |
| ≥−6.00 D | VisuMax | 0.0 | 0.0 | 0 | 0.5 | 0.3 | 38.5 | 0.4 | 0.2 | 30.8 | 0.3 | 0.2 | 18.2 |
| IntraLase | 0.1 | 0.1 | 8.3 | 0.6 | 0.3 | 16.7 | 0.3 | 0.2 | 25.0 | 0.2 | 0.2 | 20.0 | |
| Eyes (n) | 25 | 25 | 25 | 21 | |||||||||
| <−6.00 D | VisuMax | 0.0 | 0.0 | 3.2 | 0.7 | 0.2 | 35.5 | 0.1 | 0.1 | 6.5 | 0.2 | 0.1 | 21.4 |
| IntraLase | 0.0 | 0.0 | 0 | 0.9 | 0.2 | 46.9 | 0.2 | 0.1 | 15.6 | 0.3 | 0.1 | 13.8 | |
| Eyes (n) | 65 | 65 | 65 | 57 | |||||||||
Notes: Estimated mean of corneal staining score ± standard error. VisuMax (Carl Zeiss Meditec, Jena, Germany) and IntraLase™ (Abbott Medical Optics Inc, Santa Ana, CA, USA).
Abbreviations: LASIK, laser in situ keratomileusis; SE, standard error; D, diopter.