PURPOSE: We examined the effects of large breast separation (BS) on dosimetric and positional differences of radiation treatment plans of locally advanced breast cancers during a free-breathing respiratory cycle. MATERIALS AND METHODS: Computed tomography (CT) datasets of 18 patients were acquired using 3D, 4D-0% (end-inspiration), and 4D-50% (end-exhalation). BS was examined in relation to the positional and dosimetric changes to organs-at-risk (OAR). Based on dosimetric analysis of all three plans, we compared 4D-0% and 4D-50% for V5, V10, and V20 to 3D for heart and ipsilateral lung. Using 4D-0% and 4D-50% CTs, we recorded positional variations of the organs' centroid (centers of mass) and their effects on dosimetry. RESULTS: Median BS was 23.95 cm (range: 16.86-29.48 cm). There was a strong positive correlation between BS and dose to the ipsilateral lung for V5, V10, and V20, with the greatest linearity observed at V20 (R(2) = 0.23). At BS ≥ 27 cm, the dose increased during inspiration at V5, V10 , and V20 (P < 0.05). When comparing 4D and 3D for the heart, V5 and V10, decreased by average of 0.94% and 0.96% (P < 0.008), respectively. CONCLUSIONS: This study offers the first evidence of the impact of a large BS on radiation dose to the ipsilateral lung.
PURPOSE: We examined the effects of large breast separation (BS) on dosimetric and positional differences of radiation treatment plans of locally advanced breast cancers during a free-breathing respiratory cycle. MATERIALS AND METHODS: Computed tomography (CT) datasets of 18 patients were acquired using 3D, 4D-0% (end-inspiration), and 4D-50% (end-exhalation). BS was examined in relation to the positional and dosimetric changes to organs-at-risk (OAR). Based on dosimetric analysis of all three plans, we compared 4D-0% and 4D-50% for V5, V10, and V20 to 3D for heart and ipsilateral lung. Using 4D-0% and 4D-50% CTs, we recorded positional variations of the organs' centroid (centers of mass) and their effects on dosimetry. RESULTS: Median BS was 23.95 cm (range: 16.86-29.48 cm). There was a strong positive correlation between BS and dose to the ipsilateral lung for V5, V10, and V20, with the greatest linearity observed at V20 (R(2) = 0.23). At BS ≥ 27 cm, the dose increased during inspiration at V5, V10 , and V20 (P < 0.05). When comparing 4D and 3D for the heart, V5 and V10, decreased by average of 0.94% and 0.96% (P < 0.008), respectively. CONCLUSIONS: This study offers the first evidence of the impact of a large BS on radiation dose to the ipsilateral lung.
Authors: Tanja Alderliesten; Wilma D Heemsbergen; Anja Betgen; Rajko Topolnjak; Paula H M Elkhuizen; Corine van Vliet-Vroegindeweij; Peter Remeijer Journal: Phys Imaging Radiat Oncol Date: 2018-05-31