S H Han1, A Y Oh, C W Jung, S J Park, J H Kim, F S Nahm.
Abstract
During fibreoptic intubation, it is often difficult to advance a tracheal tube over the fibreoptic bronchoscope. We performed a prospective randomised study to investigate the effect of the jaw-thrust manoeuvre on the ability to advance a tracheal tube during oral fibreoptic intubation. After placing the bronchoscope in the trachea, an assistant randomly applied a jaw-thrust manoeuvre (jaw-thrust group) or sham manoeuvre (control group) in 82 patients during tube advancement. The jaw-thrust group had a higher success rate on the first attempt (70.7% vs 34.1%, p = 0.002), required fewer attempts (median (IQR [range]) 1 (1-2 [1-3]) vs 2 (1-3 [1-4]), p < 0.001), and took less time [6 (4-8 [2-16]) s vs 10 (7-15 [3-40]) s, p < 0.001] for tube advancement compared with the control group. The jaw-thrust manoeuvre facilitates the advancement of a tracheal tube over the bronchoscope during oral fibreoptic intubation. AnaesthesiaEntities:
Mesh:
Year: 2013 PMID: 23573843 DOI: 10.1111/anae.12176