Literature DB >> 23571117

Real-time feedback can improve infant manikin cardiopulmonary resuscitation by up to 79%--a randomised controlled trial.

Philip Martin1, Peter Theobald, Alison Kemp, Sabine Maguire, Ian Maconochie, Michael Jones.   

Abstract

SETTING: European and Advanced Paediatric Life Support training courses. PARTICIPANTS: Sixty-nine certified CPR providers.
INTERVENTIONS: CPR providers were randomly allocated to a 'no-feedback' or 'feedback' group, performing two-thumb and two-finger chest compressions on a "physiological", instrumented resuscitation manikin. Baseline data was recorded without feedback, before chest compressions were repeated with one group receiving feedback. MAIN OUTCOME MEASURES: Indices were calculated that defined chest compression quality, based upon comparison of the chest wall displacement to the targets of four, internationally recommended parameters: chest compression depth, release force, chest compression rate and compression duty cycle.
RESULTS: Baseline data were consistent with other studies, with <1% of chest compressions performed by providers simultaneously achieving the target of the four internationally recommended parameters. During the 'experimental' phase, 34 CPR providers benefitted from the provision of 'real-time' feedback which, on analysis, coincided with a statistical improvement in compression rate, depth and duty cycle quality across both compression techniques (all measures: p<0.001). Feedback enabled providers to simultaneously achieve the four targets in 75% (two-finger) and 80% (two-thumb) of chest compressions.
CONCLUSIONS: Real-time feedback produced a dramatic increase in the quality of chest compression (i.e. from <1% to 75-80%). If these results transfer to a clinical scenario this technology could, for the first time, support providers in consistently performing accurate chest compressions during infant CPR and thus potentially improving clinical outcomes.
Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Cardiopulmonary resuscitation; Chest compression; Feedback; Infant; Manikins; Paediatric

Mesh:

Year:  2013        PMID: 23571117     DOI: 10.1016/j.resuscitation.2013.03.029

Source DB:  PubMed          Journal:  Resuscitation        ISSN: 0300-9572            Impact factor:   5.262


  14 in total

1.  Singapore Neonatal Resuscitation Guidelines 2016.

Authors:  Cheo Lian Yeo; Agnihotri Biswas; Teong Tai Kenny Ee; Amutha Chinnadurai; Vijayendra Ranjan Baral; Alvin Shang Ming Chang; Imelda Lustestica Ereno; Kah Ying Selina Ho; Woei Bing Poon; Varsha Atul Shah; Bin Huey Quek
Journal:  Singapore Med J       Date:  2017-07       Impact factor: 1.858

Review 2.  Randomized controlled trials of simulation-based interventions in Emergency Medicine: a methodological review.

Authors:  Anthony Chauvin; Jennifer Truchot; Aida Bafeta; Dominique Pateron; Patrick Plaisance; Youri Yordanov
Journal:  Intern Emerg Med       Date:  2017-11-16       Impact factor: 3.397

3.  Effect of metronome guidance on infant cardiopulmonary resuscitation.

Authors:  Chan Woong Kim; Je Hyeok Oh
Journal:  Eur J Pediatr       Date:  2019-03-08       Impact factor: 3.183

4.  Provider Adherence to Neonatal Resuscitation Program Recommendations for Coordinated Neonatal Chest Compressions and Ventilations.

Authors:  Elizabeth Foglia; Jay Patel; Dana Niles; Per Helge Aasland; Vinay Nadkarni; Anne Ades
Journal:  Analg Resusc       Date:  2013-07-25

5.  Does real-time objective feedback and competition improve performance and quality in manikin CPR training--a prospective observational study from several European EMS.

Authors:  J R Smart; K Kranz; F Carmona; T W Lindner; A Newton
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2015-10-15       Impact factor: 2.953

6.  Randomised crossover trial of rate feedback and force during chest compressions for paediatric cardiopulmonary resuscitation.

Authors:  Rachael Kathleen Gregson; Tim James Cole; Sophie Skellett; Emmanouil Bagkeris; Denise Welsby; Mark John Peters
Journal:  Arch Dis Child       Date:  2016-10-24       Impact factor: 3.791

7.  Evaluation of a newly developed infant chest compression technique: A randomized crossover manikin trial.

Authors:  Jacek Smereka; Karol Bielski; Jerzy R Ladny; Kurt Ruetzler; Lukasz Szarpak
Journal:  Medicine (Baltimore)       Date:  2017-04       Impact factor: 1.889

8.  Smartwatch feedback device for high-quality chest compressions by a single rescuer during infant cardiac arrest: a randomized, controlled simulation study.

Authors:  Juncheol Lee; Yeongtak Song; Jaehoon Oh; Youngjoon Chee; Chiwon Ahn; Hyungoo Shin; Hyunggoo Kang; Tae Ho Lim
Journal:  Eur J Emerg Med       Date:  2019-08       Impact factor: 2.799

9.  Analysis of Chest-Compression Depth and Full Recoil in Two Infant Chest-Compression Techniques Performed by a Single Rescuer: Systematic Review and Meta-Analysis.

Authors:  Chun-Yu Chang; Po-Chen Lin; Yung-Jiun Chien; Chien-Sheng Chen; Meng-Yu Wu
Journal:  Int J Environ Res Public Health       Date:  2020-06-05       Impact factor: 3.390

10.  Do automated real-time feedback devices improve CPR quality? A systematic review of literature.

Authors:  Debora Gugelmin-Almeida; Lucia Tobase; Thatiane Facholi Polastri; Heloisa Helena Ciqueto Peres; Sergio Timerman
Journal:  Resusc Plus       Date:  2021-03-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.