Abstract
A sensitive and selective confirmatory method for milk-residue analysis of ten quinolones and eight cephalosporins by LC-MS/MS has been developed herein. For the chromatographic separation of target analytes, a Perfectsil ODS-2 (250 × 4 mm, 5 μm) analytical column was used and gradient elution was applied, using a mobile phase of 0.1% w/w TFA in water and 0.1% w/w TFA in ACN. Ultrasound-assisted matrix solid-phase dispersion procedure was applied for the extraction and clean-up procedure of antimicrobials agents from milk matrix using a mixture of Bond Elut Plexa sorbent and QuEChERS. The method was validated meeting the European Legislation determining selectivity, linearity response, trueness, precision (repeatability and between-day reproducibility), decision limit, detection capability, and ruggedness following the Youden approach. Recoveries of all antibiotics ranged from 81.7 to 117.9%, while RSD values were lower than 13.7%. Limits of quantification for all examined compounds ranged from 2.4 to 15.0 μg/kg, substantially lower than the maximum residue limits established by the European Union (30-100 μg/kg).Mesh:
Substances:
Year: 2013 PMID: 23568854 DOI: 10.1002/jssc.201300194