Literature DB >> 23568828

High-precision characterization of individual E. coli cell morphology by scanning flow cytometry.

Anastasiya I Konokhova1, Andrey A Gelash, Maxim A Yurkin, Andrey V Chernyshev, Valeri P Maltsev.   

Abstract

We demonstrate a flow-cytometric method to measure length and diameter of single Escherichia coli cells with sub-diffraction precision. The method is based on the original scanning flow cytometer that measures angle-resolved light-scattering patterns (LSPs) of individual particles. We modeled the shape of E. coli cells as a cylinder capped with hemispheres of the same radius, and simulated light scattering by the models using the discrete dipole approximation. We computed a database of the LSPs of individual bacteria in a wide range of model parameters and used it to solve the inverse light-scattering problem by the nearest-neighbor interpolation. The solution allows us to determine length and diameter of each individual bacterium, including uncertainties of these estimates. The developed method was tested on two strains of E. coli. The resulting precision of bacteria length and diameter measurements varied from 50 nm to 250 nm and from 5 nm to 25 nm, respectively. The measured distributions of samples over length and diameter were in good agreement with measurements performed by optical microscopy and literature data. The described approach can be applied for rapid morphological characterization of any rod-shaped bacteria.
Copyright © 2013 International Society for Advancement of Cytometry.

Entities:  

Mesh:

Year:  2013        PMID: 23568828     DOI: 10.1002/cyto.a.22294

Source DB:  PubMed          Journal:  Cytometry A        ISSN: 1552-4922            Impact factor:   4.355


  3 in total

Review 1.  Challenges of metagenomics and single-cell genomics approaches for exploring cyanobacterial diversity.

Authors:  Michelle Davison; Eric Hall; Richard Zare; Devaki Bhaya
Journal:  Photosynth Res       Date:  2014-12-17       Impact factor: 3.573

2.  Essential validation methods for E. coli strains created by chromosome engineering.

Authors:  Sriram Tiruvadi Krishnan; M Charl Moolman; Theo van Laar; Anne S Meyer; Nynke H Dekker
Journal:  J Biol Eng       Date:  2015-07-01       Impact factor: 4.355

3.  In vitro optoacoustic flow cytometry with light scattering referencing.

Authors:  Markus Seeger; Andre C Stiel; Vasilis Ntziachristos
Journal:  Sci Rep       Date:  2021-01-26       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.