Effects of in vitro cyclic dislodging on retentive force and removal torque of three overdenture attachment systems.

Mariko Kobayashi1, Murali Srinivasan, Patrick Ammann, Jean Perriard, Chikahiro Ohkubo, Frauke Müller, Urs C Belser, Martin Schimmel.   

Abstract

BACKGROUND: Mandibular two-implant-retained overdentures were suggested as first choice of treatment for edentulous mandibles. However, wear of the attachments may reduce their retention and compromise long-term clinical success. AIM: The aim of this in vitro study was to compare the change in the retentive force and removal torque of three attachment systems during simulation of insertion-removal cycles.
MATERIALS AND METHODS: Thirty custom-manufactured polyvinyl chloride blocks mimicking an implant-retained overdenture using Locator(®) -, spherical Dalbo(®) -PLUS - and SFI(®) -Bar-attachments on Straumann(®) RN Implants were fabricated. The samples were distributed equally into three groups which were subdivided into two sets of five blocks, one set with implants parallel to one another and the other with angulated implants (12°). All attachments were tightened to 35Ncm, while the fixation screws of the SFI(®) -Bar were tightened to 15Ncm. Testing was carried out with an Instron(®) universal testing machine for a total of 14,600 insertion-removal cycles in 0.9% sodium chloride solution. Retentive forces from cycles 10, 100, 1000, 5000, 10,000 and 14,600 were used for the analysis. The removal torque of the attachments was measured before and at the end of the study. Statistical analysis comprised three-way ANOVA and multiple linear regression models.
RESULTS: Initially, all three attachment systems demonstrated increasing retentive forces. From cycle 5000 on, Locator(®) -attachments showed lower mean retentive forces than the Dalbo(®) -PLUS and SFI(®) -Bar-groups. The Dalbo(®) -PLUS and SFI(®) -Bar-attachments showed a steady yet not significant increase during the whole observation period. Implant-angulation had no significant influence on the retention forces. The final mean removal torques were significantly reduced. No complete failure was observed. CONCLUSIONS AND CLINICAL IMPLICATIONS: Within the limits of this in vitro study, it can be concluded that the investigated overdenture attachment systems are sufficiently resistant to wear. However, the Dalbo(®) -Plus- and SFI(®) -Bar- exhibit higher retentive capacities than the Locator(®) -attachment over time. The fixation screw of the SFI(®) -Bar may loosen during long-term use, but these observations might be less important if 1-year recall intervals are respected. An angulation of up to 12° between implants does not seem to have a significant effect on attachment wear.
© 2013 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

Entities:  

Keywords:  Dalbo®-PLUS; Locator®; SFI-Bar®; dislodging cycles; in vitro; overdenture attachment; removal torque; retentive force

Mesh:

Year:  2013        PMID: 23566266     DOI: 10.1111/clr.12156

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  14 in total

1.  The influence of saliva pH value on the retention and durability of bar-clip attachments.

Authors:  Antonio Sergio Silva; Carlos Aroso; Raul Ustrell; Ana Cristina Braga; Jose Manuel Mendes; Tomas Escuin
Journal:  J Adv Prosthodont       Date:  2015-02-17       Impact factor: 1.904

2.  In vitro retention force measurement for three different attachment systems for implant-retained overdenture.

Authors:  Kareem Mohammed Reda; Ibrahim Ramadan El-Torky; Mohamed Nabeel El-Gendy
Journal:  J Indian Prosthodont Soc       Date:  2016 Oct-Dec

3.  A comparative evaluation of fatigue resistance of two different implant overdenture stud attachments with two different denture base materials: An in vitro study.

Authors:  Namrata Agrawal; Sumeet Jain; Deepak Agrawal
Journal:  J Indian Prosthodont Soc       Date:  2018 Jan-Mar

4.  Effect of Implant Location on Palateless Complete Overdenture Retention: an In Vitro Study.

Authors:  Nesma El-Amier; Ehab Elsaih; Mona Gibreel; Hassan El-Motaiam
Journal:  J Oral Maxillofac Res       Date:  2018-09-30

5.  Clinical evaluation of inter-implant distance influence on the wear characteristics of low-profile stud attachments used in mandibular implant‑retained overdentures.

Authors:  Nesreen El Mekawy; Mohamed-Yosry Elhawary
Journal:  J Clin Exp Dent       Date:  2019-01-01

6.  Wear, microleakage and plastic deformation of an implant-supported chair-side bar system.

Authors:  Christian Johannes Mehl; Martin Steiner; Klaus Ludwig; Matthias Kern
Journal:  J Adv Prosthodont       Date:  2015-08-18       Impact factor: 1.904

7.  An in vitro comparative study to evaluate the retention of different attachment systems used in implant-retained overdentures.

Authors:  Tejomaya Shastry; N M Anupama; Shilpa Shetty; M Nalinakshamma
Journal:  J Indian Prosthodont Soc       Date:  2016 Apr-Jun

8.  Effect of abutment angulation in the retention and durability of three overdenture attachment systems: An in vitro study.

Authors:  Carlos Aroso; Antonio Sergio Silva; Raul Ustrell; Jose Manuel Mendes; Ana Cristina Braga; Esther Berastegui; Tomas Escuin
Journal:  J Adv Prosthodont       Date:  2016-02-23       Impact factor: 1.904

9.  In vitro retention capacity of two overdenture attachment systems: Locator® and Equator®.

Authors:  Nieves Mínguez-Tomás; Jorge Alonso-Pérez-Barquero; Lucía Fernández-Estevan; Ángel Vicente-Escuder; Eduardo J Selva-Otaolaurruchi
Journal:  J Clin Exp Dent       Date:  2018-07-01

10.  Clinical performance of LOCATOR® attachments: A retrospective study with 1-8 years of follow-up.

Authors:  Christophe Guédat; Ursina Nagy; Martin Schimmel; Frauke Müller; Murali Srinivasan
Journal:  Clin Exp Dent Res       Date:  2018-07-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.