Literature DB >> 23564537

Further experience with the "no-react" bioprosthesis in patients with active infective endocarditis: 11-year single center results in 402 patients.

Michele Musci1, Aref Amiri, Henryk Siniawski, Julia Stein, Yuguo Weng, Roland Hetzer.   

Abstract

OBJECTIVES: We investigated early, midterm, and long-term results following valve replacement with the "No-React" bioprosthesis in patients with active infective endocarditis (AIE).Patients and Methods Between February 2000 and February 2011, a total of 402 patients (median 61 years, 17 to 91 years) received "No-React" bioprostheses due to single valve AIE in 315 (aortic valve replacement n = 158, aortic conduit n = 30, mitral valve replacement n = 116, tricuspid valve replacement n = 11) and double valve AIE in 87 cases. Prosthetic AIE was found in 105 patients (26.1%). Mean follow-up was 2.8 ± 3.2 years (1 month to 11.4 years) with 1,124 patient years, completed in 97.1%. This retrospective study analyzes both prospectively updated data (n = 255) and patients recently operated upon (n = 147).
RESULTS: There was a highly significant difference in the survival between patients operated on urgently and patients operated on in an emergency (30-day, 1-, 5-, and 10-year survival were 80.9 ± 2.3%, 63.8 ± 2.9%, 48.3 ± 3.3%, and 39.7 ± 4.1% vs. 61.3 ± 4.5%, 45.0 ± 4.7%, 33.1 ± 4.6%, and 14.0 ± 5.1%, respectively, p < 0.001), due to native versus prosthetic AIE (p = 0.032), single versus double valve replacement (p = 0.005), and with or without abscess formation (p < 0.001). Thirty-day, 1-, 5-, and 10-year freedom from reoperation due to recurrent endocarditis were 100%, 95.1 ± 1.4%, 86.4 ± 2.6%, and 82.1 ± 3.6% and due to structural valve deterioration (SVD) were 100%, 100%, 98.9 ± 0.8%, and 91.4 ± 4.0%, respectively. There was no difference in prosthesis durability between the older (> 60 years) and the younger patients.
CONCLUSIONS: Our experience in the use of "No-React" bioprostheses in patients with native and prosthetic AIE shows satisfactory early, midterm, and long-term results, in particular low rates of reoperation due to recurrent endocarditis and SVD. Because these prostheses are readily available and their implantation straightforward, we strongly recommend their use in patients with AIE. Patients' survival differed significantly depending on their surgical urgency. Early mortality was independently predicted by septic shock, abscess formation, and number of implanted valves besides age per 10 years. Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2013        PMID: 23564537     DOI: 10.1055/s-0033-1337903

Source DB:  PubMed          Journal:  Thorac Cardiovasc Surg        ISSN: 0171-6425            Impact factor:   1.827