| Literature DB >> 23562435 |
P Planinšek1, L Benedik, B Smodiš.
Abstract
The aim of the present study was to compare three wet digestion procedures for dissolution of biological samples in the determination of Po-210. Classical wet ashing over a gas flame with acids in a long-necked Kjeldahl flask, digestion with acids in an Erlenmeyer flask and microwave digestion in a Teflon vessel at temperatures at up to 200°C were investigated. The results obtained showed that the activity concentrations of Po-210 found in the samples analysed were comparable for all the procedures used.Keywords: Alpha-particle spectrometry; Biological samples; Dissolution; Polonium
Mesh:
Substances:
Year: 2013 PMID: 23562435 DOI: 10.1016/j.apradiso.2013.03.008