Literature DB >> 23560929

The ability of the Reciproc R25 instrument to reach the full root canal working length without a glide path.

G De-Deus1, T E P Arruda, E M Souza, A Neves, K Magalhães, E Thuanne, R A S Fidel.   

Abstract

AIM: To assess the frequency in which the Reciproc instrument reaches the full working length (FWL) of mandibular molar canals without a glide path.
METHODOLOGY: From a pool of mandibular molars, 253 root canals were classified as straight (G1) and, 249 root canals as moderately curved (G2) following Schneider's method. A R25 Reciproc instrument (VDW, Munich, Germany) was advanced in the canals without any previous glide path. All cases where Reciproc instruments reached the FWL were classified as 'Reaching the FWL' (RFWL). When the FWL was not reached by the R25, the root canals were classified as 'Not Reaching the FWL' (NRFWL). Pearson's χ(2) test compared (i) the frequency distributions of root canals classified as RFWL and NRFWL for each group and (ii) the frequency distributions of NRFWL canals between the groups.
RESULTS: In G1, 9 cases (3.56%) and in G2, 23 canals (9.34%) were classified as NRFWL. The difference between NRFWL and RFWL was significant in both groups (P = 0.00, χ(2) = 217.2 for G1; P = 0.00, χ(2) = 167.8 for G2). The frequency of NRFWL was significantly higher for G2 (P = 0.02, χ(2) = 5.452).
CONCLUSION: The R25 Reciproc instrument is able to reach the FWL of straight- and moderate-curved mandibular molar canals without a glide path in a large proportion of cases.
© 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

Keywords:  glide path; reciprocation; root canal instrumentation

Mesh:

Year:  2013        PMID: 23560929     DOI: 10.1111/iej.12091

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  18 in total

1.  Apically extruded dentin debris by reciprocating single-file and multi-file rotary system.

Authors:  Gustavo De-Deus; Aline Neves; Emmanuel João Silva; Thais Accorsi Mendonça; Caroline Lourenço; Camila Calixto; Edson Jorge Moreira Lima
Journal:  Clin Oral Investig       Date:  2014-06-21       Impact factor: 3.573

Review 2.  Shaping the root canal system.

Authors:  M Waplington; A S McRobert
Journal:  Br Dent J       Date:  2014-03       Impact factor: 1.626

3.  Canal preparation with nickel-titanium or stainless steel instruments without the risk of instrument fracture: preliminary observations.

Authors:  Ghassan Yared
Journal:  Restor Dent Endod       Date:  2014-11-13

4.  The impact of clinical use on the torsional behavior of Reciproc and WaveOne instruments.

Authors:  Rafael Rodrigues Soares de Magalhães; Lígia Carolina Moreira Braga; Érika Sales Joviano Pereira; Isabella Faria da Cunha Peixoto; Vicente Tadeu Lopes Buono; Maria Guiomar de Azevedo Bahia
Journal:  J Appl Oral Sci       Date:  2016 Jul-Aug       Impact factor: 2.698

5.  Cleaning Effectiveness of a Reciprocating Single-file and a Conventional Rotary Instrumentation System.

Authors:  Fredson Marcio Acris de Carvalho; Leonardo Cantanhede de Oliveira Gonçalves; André Augusto Franco Marques; Vanessa Alves; Carlos Eduardo da Silveira Bueno; Alexandre Sigrist De Martin
Journal:  Open Dent J       Date:  2016-12-26

6.  The ability of Reciproc instruments to reach full working length without glide path preparation: a clinical retrospective study.

Authors:  Andreas Bartols; Bernt-Peter Robra; Winfried Walther
Journal:  PeerJ       Date:  2017-07-19       Impact factor: 2.984

7.  Effects of Glide Path on the Centering Ability and Preparation Time of Two Reciprocating Instruments.

Authors:  Marcelo Santos Coelho; Carlos Eduardo Fontana; Augusto Shoji Kato; Alexandre Sigrist de Martin; Carlos Eduardo da Silveira Bueno
Journal:  Iran Endod J       Date:  2015-12-24

8.  Reciproc vs. hand instrumentation in dental practice: a study in routine care.

Authors:  Andreas Bartols; Claudius A Reutter; Bernt-Peter Robra; Winfried Walther
Journal:  PeerJ       Date:  2016-06-28       Impact factor: 2.984

9.  Influence of reuse and cervical preflaring on the fracture strength of reciprocating instruments.

Authors:  Claudio Maniglia-Ferreira; Fabio de Almeida Gomes; Tatyana Ximenes; Murilo Alves Teixeira Neto; Thiane Elys Arruda; Giovani Gonçalves Ribamar; Luis Flávio Gaspar Herculano
Journal:  Eur J Dent       Date:  2017 Jan-Mar

10.  Does adding an instrument after root preparation with Reciproc® R25 increase bacterial reduction?

Authors:  Fernando Soveral D'aviz; Ana Paula Farina; Matheus Albino Souza; Doglas Cecchin
Journal:  J Conserv Dent       Date:  2018 May-Jun
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.