BACKGROUND: High-voltage overhead power lines (HVOLs) are a source of extremely low-frequency magnetic fields (ELF-MFs), which are classified as possible risk factors for childhood acute leukaemia (AL). The study was carried out to test the hypothesis of an increased AL incidence in children living close to HVOL of 225-400 kV (VHV-HVOL) and 63-150 kV (HV-HVOL).Entities:
Mesh:
Year: 2013 PMID: 23558899 PMCID: PMC3658518 DOI: 10.1038/bjc.2013.128
Source DB: PubMed Journal: Br J Cancer ISSN: 0007-0920 Impact factor: 7.640
Distribution of the cases and controls by category of uncertainty of location by geocoding
| | | ||||
|---|---|---|---|---|---|
| At the exact number | 20 m | 1946 | 70.0 | 23 171 | 77.2 |
| In a section of a short street | 50 m | 173 | 6.2 | 1658 | 5.5 |
| At a close number | 100 m | 130 | 4.7 | 801 | 2.7 |
| In a medium street or in a hamlet | 300 m | 394 | 14.2 | 3693 | 12.3 |
| In a long street | 500 m | 54 | 1.9 | 383 | 1.3 |
| In a Commune | | 82 | 3.0 | 292 | 1.0 |
| Total | 2779 | 100.0 | 30 000 | 100.0 | |
Description of the cases included in the study, by the distance between their residence and the closest HVOL and by voltage category (very high (225–400 kV) or high (63–150 kV)) over the period 2002–2007
| Female | 4 | 12 | 1246 | 7 | 26 | 1229 | 1262 |
| Male | 5 | 12 | 1500 | 7 | 28 | 1482 | 1517 |
| <5 years | 6 | 11 | 1291 | 8 | 24 | 1276 | 1308 |
| 5–9 years | 3 | 10 | 858 | 2 | 18 | 851 | 871 |
| 10–14 years | 0 | 3 | 597 | 4 | 12 | 584 | 600 |
| Down's syndrome | 0 | 0 | 43 | 0 | 0 | 43 | 43 |
| 8 | 21 | 2250 | 13 | 46 | 2220 | 2279 | |
| B-cell precursor ALL | 6 | 12 | 1056 | 8 | 25 | 1041 | 1074 |
| T-cell ALL | 0 | 0 | 173 | 1 | 4 | 168 | 173 |
| Other ALL | 2 | 9 | 1021 | 4 | 17 | 1011 | 1032 |
| AML | 1 | 2 | 428 | 1 | 6 | 424 | 431 |
| Other AL | 0 | 1 | 68 | 0 | 2 | 67 | 69 |
Abbreviations: AL=acute leukaemia; ALL=acute lymphoblastic leukaemia; AML=acute myeloblastic leukaemia; HVOL=high-voltage overhead power line.
Association between childhood acute leukaemia and distance to the closest HVOL by category of voltage (very high (225–400 kV) or high (63–150 kV)) over the period 2002–2007
| | | | | | | | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Baseline | 610 | 22.0 | 7061 | 23.5 | 1.0 | Reference | 610 | 22.0 | 7061 | 23.5 | 1.0 | Reference | 610 | 22.0 | 7061 | 23.5 | 1.0 | Reference |
| Unknown | 67 | | 203 | | | | 67 | | 203 | | | | 67 | | 203 | | | |
| ⩾600 m | 1924 | 69.2 | 20 896 | 69.7 | 1.0 | (0.9–1.2) | 1792 | 64.5 | 19 168 | 63.9 | 1.1 | (1.0–1.2) | 1665 | 59.9 | 17 937 | 59.8 | 1.1 | (0.9–1.2) |
| 200–599 m | 145 | 5.2 | 1416 | 4.7 | 1.2 | (1.0–1.4) | 242 | 8.7 | 2740 | 9.1 | 1.0 | (0.8–1.2) | 345 | 12.4 | 3633 | 12.1 | 1.1 | (0.9–1.2) |
| 100–199 m | 16 | 0.6 | 267 | 0.9 | 0.7 | (0.4–1.2) | 33 | 1.2 | 461 | 1.5 | 0.8 | (0.6–1.2) | 44 | 1.6 | 669 | 2.2 | 0.8 | (0.5–1.0) |
| 50–99 m | 8 | 0.3 | 97 | 0.3 | 1.0 | (0.5–2.1) | 21 | 0.8 | 203 | 0.7 | 1.2 | (0.7–1.9) | 25 | 0.9 | 284 | 0.9 | 1.0 | (0.7–1.6) |
| 0–49 m | 9 | 0.3 | 60 | 0.2 | 1.7 | (0.9–3.6) | 14 | 0.5 | 164 | 0.5 | 1.0 | (0.6–1.7) | 23 | 0.8 | 213 | 0.7 | 1.2 | (0.8–1.9) |
| Total | 2779 | 30 000 | 2779 | 30 000 | 2779 | 30 000 | ||||||||||||
Abbreviations: CI=confidence interval; HVOL=high-voltage overhead power line; OR=odds ratio.
OR and 95% CIs estimated by logistic regression adjusted for age at the end of the year (5-year age groups for the 0–14-year-old children, 1-year age groups for the 0–4-year-old children) and Département of residence.
Residence in a Commune entirely located ⩾600 m from an HVOL.
Association between childhood AL and distance from HVOLs over the period 2002–2007, stratified by age and urban status of the Commune of residence
| Baseline | 311 | 23.8 | 2326 | 23.9 | 1.0 | Reference | 311 | 23.8 | 2326 | 23.9 | 1.0 | Reference |
| Unknown | 35 | 85 | 35 | 85 | ||||||||
| ⩾600 m | 870 | 66.6 | 6734 | 69.3 | 0.9 | (0.8–1.1) | 814 | 62.3 | 6146 | 63.2 | 0.9 | (0.8–1.1) |
| 200–599 m | 74 | 5.7 | 444 | 4.6 | 1.2 | (0.9–1.6) | 115 | 8.8 | 902 | 9.3 | 0.9 | (0.7–1.1) |
| 100–199 m | 5 | 0.4 | 87 | 0.9 | 0.4 | (0.2–1.0) | 13 | 1.0 | 145 | 1.5 | 0.6 | (0.4–1.2) |
| 50–99 m | 6 | 0.5 | 27 | 0.3 | 1.6 | (0.7–4.1) | 11 | 0.8 | 61 | 0.6 | 1.3 | (0.7–2.5) |
| 0–49 m | 6 | 0.5 | 14 | 0.1 | 2.6 | (1.0–6.9) | 8 | 0.6 | 52 | 0.5 | 1.1 | (0.5–2.3) |
| Total | 1307 | | 9717 | | | | 1307 | | 9717 | | | |
| Baseline | 299 | 20.3 | 4735 | 23.3 | 1.0 | Reference | 299 | 20.8 | 4735 | 23.3 | 1.0 | Reference |
| Unknown | 32 | 118 | 32 | 118 | ||||||||
| ⩾600 m | 1054 | 71.6 | 14 162 | 69.8 | 1.2 | (1.0–1.4) | 978 | 66.4 | 13 022 | 64.2 | 1.2 | (1.0–1.4) |
| 200–599 m | 71 | 4.8 | 972 | 4.8 | 1.2 | (0.9–1.5) | 127 | 8.6 | 1838 | 9.1 | 1.1 | (0.9–1.4) |
| 100–199 m | 11 | 0.7 | 180 | 0.9 | 1.0 | (0.5–1.8) | 20 | 1.4 | 316 | 1.6 | 1.0 | (0.6–1.6) |
| 50–99 m | 2 | 0.1 | 70 | 0.3 | 0.5 | (0.1–2.0) | 10 | 0.7 | 142 | 0.7 | 1.1 | (0.6–2.1) |
| 0–49 m | 3 | 0.2 | 46 | 0.2 | 1.0 | (0.3–3.3) | 6 | 0.4 | 112 | 0.6 | 0.9 | (0.4–2.1) |
| Total | 1472 | | 20 283 | | | | 1472 | | 20 283 | | | |
| <5000 inhabitants | ||||||||||||
| Baseline | 309 | 34.1 | 3415 | 35.5 | 1.0 | Reference | 309 | 34.1 | 3415 | 35.5 | 1.0 | Reference |
| Unknown | 36 | 67 | 36 | 67 | ||||||||
| ⩾600 m | 525 | 57.9 | 5630 | 58.6 | 1.0 | (0.9–1.2) | 482 | 53.1 | 5221 | 54.3 | 1.0 | (0.9–1.2) |
| 200–599 m | 30 | 3.3 | 393 | 4.1 | 0.9 | (0.6–1.3) | 68 | 7.5 | 724 | 7.5 | 1.0 | (0.8–1.4) |
| 100–199 m | 2 | 0.2 | 71 | 0.7 | 0.3 | (0.1–1.4) | 7 | 0.8 | 109 | 1.1 | 0.7 | (0.3–1.6) |
| 50–99 m | 1 | 0.1 | 20 | 0.2 | 0.6 | (0.1–4.6) | 4 | 0.4 | 45 | 0.5 | 1.1 | (0.4–3.0) |
| 0–49 m | 4 | 0.4 | 19 | 0.2 | 2.5 | (0.8–7.7) | 1 | 0.1 | 34 | 0.4 | 0.4 | (0.1–2.9) |
| Total | 907 | | 9615 | | | | 907 | | 9615 | | | |
| Baseline | 71 | 11.1 | 756 | 10.9 | 1.0 | Reference | 71 | 11.1 | 756 | 10.9 | 1.0 | Reference |
| Unknown | 18 | 63 | 18 | 63 | ||||||||
| ⩾600 m | 513 | 80.3 | 5811 | 84.1 | 0.8 | (0.6–1.1) | 451 | 72.7 | 4942 | 71.6 | 0.9 | (0.7–1.2) |
| 200–599 m | 27 | 4.2 | 219 | 3.2 | 1.2 | (0.7–2.0) | 72 | 11.5 | 876 | 12.7 | 0.8 | (0.5–1.1) |
| 100–199 m | 5 | 0.8 | 33 | 0.5 | 1.5 | (0.5–3.9) | 15 | 2.4 | 144 | 2.1 | 1.0 | (0.5–1.8) |
| 50–99 m | 1 | 0.2 | 19 | 0.3 | 0.6 | (0.1–4.8) | 5 | 0.8 | 73 | 1.1 | 0.7 | (0.3–1.7) |
| 0–49 m | 4 | 0.6 | 6 | 0.1 | 4.9 | (1.3–19.2) | 7 | 1.1 | 53 | 0.8 | 1.2 | (0.5–2.7) |
| Total | 639 | | 6907 | | | | 639 | | 6907 | | | |
| Baseline | 230 | 18.7 | 2890 | 21.4 | 1.0 | Reference | 230 | 18.7 | 2890 | 21.4 | 1.0 | Reference |
| Unknown | 13 | 73 | 13 | 73 | ||||||||
| ⩾600 m | 886 | 71.9 | 9455 | 70.2 | 1.1 | (0.9–1.4) | 859 | 69.7 | 9005 | 66.8 | 1.2 | (0.9–1.4) |
| 200–599 m | 88 | 7.1 | 804 | 6.0 | 1.3 | (1.0–1.8) | 102 | 8.3 | 1140 | 8.5 | 1.1 | (0.8–1.4) |
| 100–199 m | 9 | 0.7 | 163 | 1.2 | 0.7 | (0.4–1.4) | 11 | 0.9 | 208 | 1.5 | 0.7 | (0.4–1.3) |
| 50–99 m | 6 | 0.5 | 58 | 0.4 | 1.4 | (0.6–3.3) | 12 | 1.0 | 85 | 0.6 | 1.7 | (0.9–3.3) |
| 0–49 m | 1 | 0.1 | 35 | 0.3 | 0.4 | (0.1–2.9) | 6 | 0.5 | 77 | 0.6 | 1.0 | (0.4–2.4) |
| Total | 1233 | 13 478 | 1233 | 13 478 | ||||||||
Abbreviations: AL=acute leukaemia; Ca=number of cases; CI=confidence interval; Co=number of controls; HVOL=high-voltage overhead power line; OR=odds ratio.
ORs and 95% CIs estimated by logistic regression adjusted for age at the end of the year (5-year age groups for the 0–14-year-old children, 1-year age groups for the 0–4-year-old children) and Département of residence.
Baseline=residence in a Commune entirely located ⩾600 m from any HVOL.
An urban unit is defined by the INSEE (National Institute of Statistics and Economic Studies) as a group of Communes in which the distance between dwellings is nowhere more than 200 m.
Sensitivity analyses of the association between childhood acute leukaemia and distance to the closest HVOL by category of voltage (very high (225–400 kV) or high (63–150 kV)) over the period 2002–2007, for all ages and the 0–4-years age group
| | | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Baseline | 610 | 7061 | 1.0 | Reference | 610 | 7061 | 1.0 | Reference | 610 | 7061 | 1.0 | Reference | 610 | 7061 | 1.0 | Reference | 610 | 7061 | 1.0 | Reference |
| 100 | 44 | 669 | 0.8 | (0.5 | 32 | 499 | 0.7 | (0.5 | 36 | 455 | 0.9 | (0.6 | ||||||||
| 50 | 25 | 284 | 1.0 | (0.7 | 20 | 212 | 1.1 | (0.7 | 22 | 184 | 1.4 | (0.9 | ||||||||
| 0 | 23 | 213 | 1.2 | (0.8 | 16 | 152 | 1.2 | (0.7 | 14 | 158 | 1.1 | (0.6 | 24 | 243 | 1.2 | (0.7 | 13 | 128 | 1.2 | (0.7 |
| 100 | 16 | 267 | 0.7 | (0.4 | 13 | 200 | 0.8 | (0.4 | 18 | 172 | 1.2 | (0.7 | ||||||||
| 50 | 8 | 97 | 1.0 | (0.5 | 6 | 68 | 1.0 | (0.4 | 8 | 74 | 1.3 | (0.6 | ||||||||
| 0 | 9 | 60 | 1.7 | (0.9 | 7 | 39 | 2.1 | (0.9 | 4 | 38 | 1.3 | (0.5 | 9 | 68 | 1.5 | (0.8 | 4 | 30 | 1.7 | (0.6 |
| 100 | 33 | 461 | 0.8 | (0.6 | 22 | 346 | 0.7 | (0.5 | 24 | 322 | 0.9 | (0.6 | ||||||||
| 50 | 21 | 203 | 1.2 | (0.7 | 16 | 155 | 1.2 | (0.7 | 14 | 121 | 1.3 | (0.7 | ||||||||
| 0 | 14 | 164 | 1.0 | (0.6 | 9 | 120 | 0.8 | (0.4 | 10 | 127 | 0.9 | (0.5 | 15 | 188 | 0.9 | (0.5 | 9 | 103 | 1.0 | (0.5 |
| 0–4 years | ||||||||||||||||||||
| Baseline | 311 | 2326 | 1.0 | Reference | 311 | 2326 | 1.0 | Reference | 311 | 2326 | 1.0 | Reference | 311 | 2326 | 1.0 | Reference | 311 | 2326 | 1.0 | Reference |
| 100 | 17 | 213 | 0.6 | (0.3 | 9 | 160 | 0.4 | (0.2 | 16 | 146 | 0.9 | (0.5 | ||||||||
| 50 | 14 | 84 | 1.2 | (0.7 | 11 | 62 | 1.2 | (0.6 | 13 | 55 | 1.7 | (0.9 | ||||||||
| 0 | 14 | 62 | 1.5 | (0.8 | 9 | 42 | 1.3 | (0.6 | 8 | 38 | 1.5 | (0.6 | 14 | 66 | 1.4 | (0.8 | 8 | 34 | 1.7 | (0.8 |
| 100 | 5 | 87 | 0.4 | (0.2 | 4 | 63 | 0.5 | (0.2 | 9 | 58 | 1.3 | (0.6 | ||||||||
| 50 | 6 | 27 | 1.6 | (0.7 | 4 | 19 | 1.6 | (0.5 | 6 | 21 | 2.1 | (0.8 | ||||||||
| 0 | 6 | 14 | 2.6 | (1.0 | 5 | 8 | 4.1 | (1.3 | 3 | 7 | 2.5 | (0.6 | 6 | 16 | 2.3 | (0.9 | 3 | 5 | 3.5 | (0.8 |
| 100 | 13 | 108 | 0.6 | (0.4 | 6 | 145 | 0.4 | (0.2 | 10 | 99 | 0.7 | (0.4 | ||||||||
| 50 | 11 | 45 | 1.3 | (0.7 | 8 | 61 | 1.2 | (0.5 | 7 | 35 | 1.5 | (0.6 | ||||||||
| 0 | 8 | 36 | 1.1 | (0.5 | 4 | 52 | 0.6 | (0.2 | 5 | 33 | 1.1 | (0.4 | 8 | 55 | 1.0 | (0.5 | 5 | 30 | 1.3 | (0.5 |
Abbreviations: Ca=number of cases; CI=confidence interval; Co=number of controls; GIS=geographic information system; HV-HVOL=high voltage high-voltage overhead power lines (63-150 kV); HVOL=high-voltage overhead power line; OR=odds ratio; VHV-HVOL=very high voltage high-voltage overhead power lines (225-400 kV).
The first sensitivity analysis (1) is restricted to the addresses best geocoded (GIS obtained with uncertainty of 20 m) and the second one (2) to the addresses for which a photographic view was available. The results shown in Tables 4 and 5 are recalled in the first columns.