Literature DB >> 23558758

Three-dimensional metabolic and radiologic gathered evaluation using VR-RENDER fusion: a novel tool to enhance accuracy in the localization of parathyroid adenomas.

Jacopo D'Agostino1, Michele Diana, Michel Vix, Stephane Nicolau, Luc Soler, Khalil Bourhala, Stephanie Hassler, Hurng-Sheng Wu, Jacques Marescaux.   

Abstract

BACKGROUND: The aim of this study was to assess the accuracy of a novel imaging modality, three-dimensional (3D) metabolic and radiologic gathered evaluation (MeRGE), for localizing parathyroid adenomas (PAs).
METHODS: Consecutive patients presenting with primary hyperparathyroidism who underwent both thin-slice cervical computed tomography (CT) and (99m)Tc-sestamibi (MIBI) scanning were included. 3D-CT reconstruction was obtained using VR-RENDER, which was used to perform 3D virtual neck exploration (3D-VNE). The MIBI scan was then fused with the 3D reconstruction to obtain 3D-MeRGE. Sensitivity, specificity, and accuracy were assessed. Parathyroid gland volume and preoperative parathormone (PTH) levels were analyzed as predictive factors of correct localization (i.e., correct quadrant).
RESULTS: A total of 108 cervical quadrants (27 patients) were analyzed. Sensitivities were 79.31, 75.86, 65.51, and 58.61 % with 3D-MeRGE, 3D-VNE, MIBI, and CT, respectively. Specificity was highest with CT (94.93 %) followed by 3D-VNE (92.4 %). MIBI and 3D-MeRGE had the same specificity (88.6 %). 3D-MeRGE and 3D-VNE achieved higher accuracy than MIBI or CT alone. Mean PTH values were significantly higher in patients with lesions that were correctly identified (true positive, TP) than in those whose lesions were missed (false negative, FN) with 3D-VNE (219.60 ± 212.77 vs. 98.75 ± 12.76 pg/ml; p = 0.01) and 3D-MeRGE (217.69 ± 213.76 vs. 09.75 ± 20.48 pg/ml; p = 0.02). The mean parathyroid gland volume difference between TP and FN was statistically significant with all modalities except CT.
CONCLUSIONS: 3D-MeRGE and 3D-VNE showed high accuracy for localization of PAs. 3D-MeRGE performed better than MIBI or CT alone for detecting small adenomas and those with a low PTH level.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23558758     DOI: 10.1007/s00268-013-2021-x

Source DB:  PubMed          Journal:  World J Surg        ISSN: 0364-2313            Impact factor:   3.352


  28 in total

Review 1.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

2.  3D virtual reality and selective vascular control for laparoscopic left hepatic lobectomy.

Authors:  D Mutter; B Dallemagne; Ch Bailey; L Soler; J Marescaux
Journal:  Surg Endosc       Date:  2008-04-29       Impact factor: 4.584

3.  Minimally invasive, video-assisted parathyroid surgery for primary hyperparathyroidism.

Authors:  P Miccoli; A Pinchera; G Cecchini; M Conte; C Bendinelli; E Vignali; A Picone; C Marcocci
Journal:  J Endocrinol Invest       Date:  1997 Jul-Aug       Impact factor: 4.256

4.  Localization of parathyroid tumors by computed tomography.

Authors:  J Kovarik; R Willvonseder; W Küster; B Niederle; R Roka; H Imhof
Journal:  N Engl J Med       Date:  1980-10-09       Impact factor: 91.245

5.  Improved preoperative planning for directed parathyroidectomy with 4-dimensional computed tomography.

Authors:  Steven E Rodgers; George J Hunter; Leena M Hamberg; Dawid Schellingerhout; David B Doherty; Gregory D Ayers; Suzanne E Shapiro; Beth S Edeiken; Mylene T Truong; Douglas B Evans; Jeffrey E Lee; Nancy D Perrier
Journal:  Surgery       Date:  2006-10-02       Impact factor: 3.982

6.  Primary hyperparathyroidism surgical management since the introduction of minimally invasive parathyroidectomy: Mayo Clinic experience.

Authors:  Clive S Grant; Geoffrey Thompson; David Farley; Jon van Heerden
Journal:  Arch Surg       Date:  2005-05

7.  Effect of minimally invasive radioguided parathyroidectomy on efficacy, length of stay, and costs in the management of primary hyperparathyroidism.

Authors:  R E Goldstein; L Blevins; D Delbeke; W H Martin
Journal:  Ann Surg       Date:  2000-05       Impact factor: 12.969

8.  Tc-99m MIBI parathyroid scintigraphy and intact parathyroid hormone levels in hyperparathyroidism.

Authors:  Guang-Uei Hung; Shyh-Jen Wang; Wan-Yu Lin
Journal:  Clin Nucl Med       Date:  2003-03       Impact factor: 7.794

9.  Virtual neck exploration for parathyroid adenomas: a first step toward minimally invasive image-guided surgery.

Authors:  Jacopo D'Agostino; James Wall; Luc Soler; Michel Vix; Quan-Yang Duh; Jacques Marescaux
Journal:  JAMA Surg       Date:  2013-03       Impact factor: 14.766

10.  Prospective evaluation of sestamibi scan, ultrasonography, and rapid PTH to predict the success of limited exploration for sporadic primary hyperparathyroidism.

Authors:  Allan Siperstein; Eren Berber; Richard Mackey; Mohammed Alghoul; Kristin Wagner; Mira Milas
Journal:  Surgery       Date:  2004-10       Impact factor: 3.982

View more
  5 in total

Review 1.  The quest for precision in transanal total mesorectal excision.

Authors:  A G Franchini Melani; M Diana; J Marescaux
Journal:  Tech Coloproctol       Date:  2015-11-26       Impact factor: 3.781

2.  Inventing the future of surgery.

Authors:  Jacques Marescaux; Michele Diana
Journal:  World J Surg       Date:  2015-03       Impact factor: 3.352

Review 3.  High intensity focused ultrasound (HIFU) applied to hepato-bilio-pancreatic and the digestive system-current state of the art and future perspectives.

Authors:  Michele Diana; Luigi Schiraldi; Yu-Yin Liu; Riccardo Memeo; Didier Mutter; Patrick Pessaux; Jacques Marescaux
Journal:  Hepatobiliary Surg Nutr       Date:  2016-08       Impact factor: 7.293

4.  18F-Fluorocholine PET and Multiphase CT Integrated in Dual Modality PET/4D-CT for Preoperative Evaluation of Primary Hyperparathyroidism.

Authors:  Valentin Pretet; Marianela Rotania; Mehdi Helali; Mihaela Ignat; Michel Vix; Alessio Imperiale
Journal:  J Clin Med       Date:  2020-06-26       Impact factor: 4.241

Review 5.  Recent Development of Augmented Reality in Surgery: A Review.

Authors:  P Vávra; J Roman; P Zonča; P Ihnát; M Němec; J Kumar; N Habib; A El-Gendi
Journal:  J Healthc Eng       Date:  2017-08-21       Impact factor: 2.682

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.