Literature DB >> 2355836

Real-time interactive magnetic resonance imaging.

A E Holsinger1, R C Wright, S J Riederer, F Farzaneh, R C Grimm, J K Maier.   

Abstract

We describe a system for performing interactive MRI in real time. Using a TR/TE 7.1/3.5 ms sequence, the operator may alter a scan parameter and observe the effects of the alteration on the image within a few hundred milliseconds. With this system, we can interactively control the oblique scan slice orientation and, using inversion pulses, the image contrast.

Mesh:

Year:  1990        PMID: 2355836     DOI: 10.1002/mrm.1910140312

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  8 in total

1.  Large field-of-view real-time MRI with a 32-channel system.

Authors:  Christopher J Hardy; Robert D Darrow; Manojkumar Saranathan; Randy O Giaquinto; Yudong Zhu; Charles L Dumoulin; Paul A Bottomley
Journal:  Magn Reson Med       Date:  2004-10       Impact factor: 4.668

Review 2.  The future of real-time cardiac magnetic resonance imaging.

Authors:  Krishna S Nayak; Bob S Hu
Journal:  Curr Cardiol Rep       Date:  2005-01       Impact factor: 2.931

Review 3.  Real-time, Interactive MRI for cardiovascular interventions.

Authors:  Elliot R McVeigh; Michael A Guttman; Peter Kellman; Amish N Raval; Robert J Lederman
Journal:  Acad Radiol       Date:  2005-09       Impact factor: 3.173

4.  Interventional cardiovascular procedures guided by real-time MR imaging: an interactive interface using multiple slices, adaptive projection modes and live 3D renderings.

Authors:  Michael A Guttman; Cenghizhan Ozturk; Amish N Raval; Venkatesh K Raman; Alexander J Dick; Ranil DeSilva; Parag Karmarkar; Robert J Lederman; Elliot R McVeigh
Journal:  J Magn Reson Imaging       Date:  2007-12       Impact factor: 4.813

5.  Extreme MRI: Large-scale volumetric dynamic imaging from continuous non-gated acquisitions.

Authors:  Frank Ong; Xucheng Zhu; Joseph Y Cheng; Kevin M Johnson; Peder E Z Larson; Shreyas S Vasanawala; Michael Lustig
Journal:  Magn Reson Med       Date:  2020-04-09       Impact factor: 4.668

6.  Imaging of myocardial infarction for diagnosis and intervention using real-time interactive MRI without ECG-gating or breath-holding.

Authors:  Michael A Guttman; Alexander J Dick; Venkatesh K Raman; Andrew E Arai; Robert J Lederman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2004-08       Impact factor: 4.668

Review 7.  Real-Time Magnetic Resonance Imaging.

Authors:  Krishna S Nayak; Yongwan Lim; Adrienne E Campbell-Washburn; Jennifer Steeden
Journal:  J Magn Reson Imaging       Date:  2020-12-09       Impact factor: 4.813

8.  Comparison of Cartesian and Non-Cartesian Real-Time MRI Sequences at 1.5T to Assess Velar Motion and Velopharyngeal Closure during Speech.

Authors:  Andreia C Freitas; Marzena Wylezinska; Malcolm J Birch; Steffen E Petersen; Marc E Miquel
Journal:  PLoS One       Date:  2016-04-13       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.