Literature DB >> 23556486

Assessment of intraoperative microaspiration: does a modified cuff shape improve sealing?

J D'Haese1, T De Keukeleire, I Remory, K Van Rompaey, V Umbrain, J Poelaert.   

Abstract

BACKGROUND: Intra-operative aspiration of oropharyngeal secretions is associated with post-operative pneumonia. The use of endotracheal tubes (ETTs) with a modified cuff shape could be one preventive action. In this clinical, prospective, randomised controlled trial, we hypothesised that altering the cuff shape to a tapered shape could reduce the aspiration incidence. The primary outcome was aspiration of dye solution into the trachea.
METHODS: Patients scheduled for lumbar surgery were intubated with either an ETT with a barrel-shaped polyvinylchloride cuff (control group, n = 30) or tapered-shaped polyvinylchloride cuff (intervention group, n = 30). Subsequently, instillation with methylthioninium chloride was performed. At 10, 30, 60, 90, and 120 min after intubation, bronchoscopy was performed assessing the degree of dye descent along the cuff and digitally stored. Single blind review of the videoclips provided data on incidence of dye aspiration and depth of penetration along the cuff.
RESULTS: The traditional cuff showed descent of dye into the trachea in 20% of the patients. Although a tapered-shaped polyvinylchloride cuff leaked up to the second third of the cuff, no dye leakage into the trachea was observed. The use of a tapered-shaped cuff had a protective role against aspiration (T30: OR 3.0, CI 1.57-5.75; P = 0.001).
CONCLUSIONS: Short-term use of tapered-shaped polyvinylchloride cuffs in surgical patients results in more effective sealing of the tracheal lumen in comparison with a traditional barrel-shaped polyvinylchloride cuffs. Further evaluation is needed to determine whether a reduction in post-operative pneumonia can be demonstrated when these cuffs are used.
© 2013 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23556486     DOI: 10.1111/aas.12119

Source DB:  PubMed          Journal:  Acta Anaesthesiol Scand        ISSN: 0001-5172            Impact factor:   2.105


  14 in total

1.  A 2015 Update on Ventilator-Associated Pneumonia: New Insights on Its Prevention, Diagnosis, and Treatment.

Authors:  Braden Waters; John Muscedere
Journal:  Curr Infect Dis Rep       Date:  2015-08       Impact factor: 3.725

Review 2.  [Ventilator-associated pneumonia (VAP) : A risk already at the time of anesthetic induction].

Authors:  L Vetter; C Konrad; G Schüpfer; M Rossi
Journal:  Anaesthesist       Date:  2017-02       Impact factor: 1.041

3.  Impact of tapered-cuff tracheal tube on microaspiration of gastric contents in intubated critically ill patients: a multicenter cluster-randomized cross-over controlled trial.

Authors:  Emmanuelle Jaillette; Christophe Girault; Guillaume Brunin; Farid Zerimech; Hélène Behal; Arnaud Chiche; Céline Broucqsault-Dedrie; Cyril Fayolle; Franck Minacori; Isabelle Alves; Stéphanie Barrailler; Julien Labreuche; Laurent Robriquet; Fabienne Tamion; Emmanuel Delaporte; Damien Thellier; Claire Delcourte; Alain Duhamel; Saad Nseir
Journal:  Intensive Care Med       Date:  2017-03-16       Impact factor: 17.440

4.  Impact of tracheal cuff shape on microaspiration of gastric contents in intubated critically ill patients: study protocol for a randomized controlled trial.

Authors:  Emmanuelle Jaillette; Guillaume Brunin; Christophe Girault; Farid Zerimech; Arnaud Chiche; Céline Broucqsault-Dedrie; Cyril Fayolle; Franck Minacori; Isabelle Alves; Stephanie Barrailler; Laurent Robriquet; Fabienne Tamion; Emmanuel Delaporte; Damien Thellier; Claire Delcourte; Alain Duhamel; Saad Nseir
Journal:  Trials       Date:  2015-09-25       Impact factor: 2.279

5.  An in vitro comparison of tracheostomy tube cuffs.

Authors:  Seamus Maguire; Frances Haury; Korinne Jew
Journal:  Med Devices (Auckl)       Date:  2015-04-21

Review 6.  How to avoid microaspiration? A key element for the prevention of ventilator-associated pneumonia in intubated ICU patients.

Authors:  Stijn I Blot; Jan Poelaert; Marin Kollef
Journal:  BMC Infect Dis       Date:  2014-11-28       Impact factor: 3.090

7.  Comparison of the cuff pressure of a TaperGuard endotracheal tube and a cylindrical endotracheal tube after lateral rotation of head during middle ear surgery: A single-blind, randomized clinical consort study.

Authors:  Eunkyung Choi; Yongmin Park; Younghoon Jeon
Journal:  Medicine (Baltimore)       Date:  2017-03       Impact factor: 1.889

8.  Optimal care and design of the tracheal cuff in the critically ill patient.

Authors:  Emmanuelle Jaillette; Ignacio Martin-Loeches; Antonio Artigas; Saad Nseir
Journal:  Ann Intensive Care       Date:  2014-02-27       Impact factor: 6.925

Review 9.  The value of polyurethane-cuffed endotracheal tubes to reduce microaspiration and intubation-related pneumonia: a systematic review of laboratory and clinical studies.

Authors:  Stijn I Blot; Jordi Rello; Despoina Koulenti
Journal:  Crit Care       Date:  2016-06-24       Impact factor: 9.097

10.  The value of poly-urethane cuffed endotracheal tubes.

Authors:  Jan Poelaert
Journal:  Crit Care       Date:  2016-09-30       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.