Literature DB >> 23552782

[An anatomical study of maxillary sinus septum of Han population in Jiangsu region using cone-beam CT].

Jun Li1, Zhi-xuan Zhou, Zhi-yao Yuan, Hua Yuan, Chao Sun, Ning Chen.   

Abstract

PURPOSE: To examine the anatomical variation of maxillary sinus septum of Han nationality in Jiangsu region by using cone-beam computed tomography (CBCT) combined with Simplant software in order to provide anatomical basis and operation instruction for oral implants after maxillary sinus lifting.
METHODS: CBCT image data were collected from 424 patients for analysis of maxillary sinus septa. Digital imaging and communications in medicine (Dicom) image files were fed into the computer-aided Simplant software and used to analyze the prevalence, location, height, orientation, and morphology of maxillary sinus septa through three-dimensional reconstruction. The data was analyzed with SPSS17.0 software package.
RESULTS: The proportion of the occurrence of maxillary sinus septa in 424 subjects was 44.81% and 21.23% of the subjects (n=90) had multiple sinus septa, while 20.52% had bilateral sinus septa (n=87). Totally 848 maxillary sinuses were observed in this study and 277 sinuses had septa with a proportion of 32.67%. The prevalence of septa was not significantly related to gender, age, and the presence or absence of teeth. Septa were located most frequently in the middle of maxillary sinus (59.94%). The mean height of sinus septa was (5.90±3.65) mm and (5.54±2.87) mm in the right and left maxillary sinus, respectively. The mean length of sinus septa was (8.15±2.40) mm and (7.88±2.73) mm in the right and left maxillary sinus, respectively.
CONCLUSIONS: Nearly 44.81% of Han population in Jiangsu region have maxillary sinus septa. The CBCT imaging technique can provide comprehensive and accurate quantitative analysis of maxillary sinus septa and is meaningful to provide anatomical basis and clinical guidance before sinus augmentation procedures.

Entities:  

Mesh:

Year:  2013        PMID: 23552782

Source DB:  PubMed          Journal:  Shanghai Kou Qiang Yi Xue        ISSN: 1006-7248


  3 in total

1.  Incidence, Size and Orientation of Maxillary Sinus Septa-A Retrospective Clinical Study.

Authors:  Laura Andreea Schiller; Horia Mihail Barbu; Stefania Andrada Iancu; Silviu Brad
Journal:  J Clin Med       Date:  2022-04-24       Impact factor: 4.964

2.  Comparison of cone-beam computed tomography and panoramic radiographs in detecting maxillary sinus septa.

Authors:  Meryem Toraman Alkurt; Ilkay Peker; Serife Degerli; Ali Rıza İlker Cebeci; Elif Sadik
Journal:  J Istanb Univ Fac Dent       Date:  2016-10-01

Review 3.  What is the frequency of anatomical variations and pathological findings in maxillary sinuses among patients subjected to maxillofacial cone beam computed tomography? A systematic review.

Authors:  J Ata-Ali; J-V Diago-Vilalta; M Melo; L Bagán; M-C Soldini; C Di-Nardo; F Ata-Ali; J-F Mañes-Ferrer
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2017-07-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.