Literature DB >> 23549533

Simultaneous quantification of flow and tissue velocities based on multi-angle plane wave imaging.

Ingvild Kinn Ekroll1, Abigail Swillens, Patrick Segers, Torbjørn Dahl, Hans Torp, Lasse Lovstakken.   

Abstract

A quantitative angle-independent 2-D modality for flow and tissue imaging based on multi-angle plane wave acquisition was evaluated. Simulations of realistic flow in a carotid artery bifurcation were used to assess the accuracy of the vector Doppler (VD) technique. Reduction in root mean square deviation from 27 cm/s to 6 cm/s and 7 cm/s to 2 cm/s was found for the lateral (vx) and axial (vz) velocity components, respectively, when the ensemble size was increased from 8 to 50. Simulations of a Couette flow phantom (vmax = 2.7 cm/s) gave promising results for imaging of slowly moving tissue, with root mean square deviation of 4.4 mm/s and 1.6 mm/s for the x- and z-components, respectively. A packet acquisition scheme providing both B-mode and vector Doppler RF data was implemented on a research scanner, and beamforming and further post-processing was done offline. In vivo results of healthy volunteers were in accordance with simulations and gave promising results for flow and tissue vector velocity imaging. The technique was also tested in patients with carotid artery disease. Using the high ensemble vector Doppler technique, blood flow through stenoses and secondary flow patterns were better visualized than in ordinary color Doppler. Additionally, the full velocity spectrum could be obtained retrospectively for arbitrary points in the image.

Entities:  

Mesh:

Year:  2013        PMID: 23549533     DOI: 10.1109/TUFFC.2013.2621

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  12 in total

1.  Temporal averaging of two-dimensional correlation functions for velocity vector imaging of cardiac blood flow.

Authors:  Hiroki Takahashi; Hideyuki Hasegawa; Hiroshi Kanai
Journal:  J Med Ultrason (2001)       Date:  2015-03-17       Impact factor: 1.314

2.  Ultrafast Harmonic Coherent Compound (UHCC) Imaging for High Frame Rate Echocardiography and Shear-Wave Elastography.

Authors:  Mafalda Correia; Jean Provost; Simon Chatelin; Olivier Villemain; Mickael Tanter; Mathieu Pernot
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-02-15       Impact factor: 2.725

3.  3-D ultrafast Doppler imaging applied to the noninvasive mapping of blood vessels in vivo.

Authors:  Jean Provost; Clement Papadacci; Charlie Demene; Jean-Luc Gennisson; Mickael Tanter; Mathieu Pernot
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-08       Impact factor: 2.725

4.  Pulse Wave Imaging Coupled With Vector Flow Mapping: A Phantom, Simulation, and In Vivo Study.

Authors:  Grigorios Marios Karageorgos; Iason-Zacharias Apostolakis; Pierre Nauleau; Vittorio Gatti; Rachel Weber; Paul Kemper; Elisa E Konofagou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-06-29       Impact factor: 3.267

5.  Quest for the Vulnerable Atheroma: Carotid Stenosis and Diametric Strain--A Feasibility Study.

Authors:  Canxing Xu; Chun Yuan; Edward Stutzman; Gador Canton; Keith A Comess; Kirk W Beach
Journal:  Ultrasound Med Biol       Date:  2015-12-23       Impact factor: 2.998

6.  Ultrasound imaging velocimetry with interleaved images for improved pulsatile arterial flow measurements: a new correction method, experimental and in vivo validation.

Authors:  Katharine H Fraser; Christian Poelma; Bin Zhou; Eleni Bazigou; Meng-Xing Tang; Peter D Weinberg
Journal:  J R Soc Interface       Date:  2017-02       Impact factor: 4.118

7.  Characterization of Vortex Flow in a Mouse Model of Ventricular Dyssynchrony by Plane-Wave Ultrasound Using Hexplex Processing.

Authors:  Akshay Shekhar; Orlando Aristizabal; Glenn I Fishman; Colin K L Phoon; Jeffrey A Ketterling
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-02-25       Impact factor: 2.725

8.  Transthoracic ultrafast Doppler imaging of human left ventricular hemodynamic function.

Authors:  Bruno-Felix Osmanski; David Maresca; Emmanuel Messas; Mickael Tanter; Mathieu Pernot
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-08       Impact factor: 2.725

9.  3D ultrafast ultrasound imaging in vivo.

Authors:  Jean Provost; Clement Papadacci; Juan Esteban Arango; Marion Imbault; Mathias Fink; Jean-Luc Gennisson; Mickael Tanter; Mathieu Pernot
Journal:  Phys Med Biol       Date:  2014-09-10       Impact factor: 3.609

10.  Ultrafast Ultrasound Imaging of Ocular Anatomy and Blood Flow.

Authors:  Raksha Urs; Jeffrey A Ketterling; Ronald H Silverman
Journal:  Invest Ophthalmol Vis Sci       Date:  2016-07-01       Impact factor: 4.799

View more