A real all-comers randomized trial comparing Xience Prime and Promus Element stents.

Jose M De la Torre Hernandez1, Tamara Garcia Camarero, Piedad Lerena, Dae-Hyun Lee, Fermin Sainz Laso, Gonzalo Martin Gorria, Javier Zueco.   

Abstract

BACKGROUND: The cobalt chromium everolimus-eluting stent (CoCr-EES) has shown the best safety and efficacy profile in the trials conducted so far. Recently, a new EES with a platinum-based platform (PtCr-EES) has been introduced in the market. There is only one study comparing both stents, but with important exclusion criteria.
OBJECTIVES: We sought to evaluate clinical outcomes with the PtCr-EES compared with the CoCr-EES in an all-comers population. We have conducted a randomized all-comers study aimed to compare these stents in a real-practice scenario.
METHODS: A total of 300 patients undergoing revascularization and suitable for long-term dual-antiplatelet therapy were randomized 1:1 to CoCr-EES or PtCr-EES. No exclusion criteria based on clinical presentation or lesion characteristics were applied.
RESULTS: The clinical and angiographic characteristics were well balanced in both groups without significant differences. At 18 months, the survival free from death and infarction was 93.9% for CoCr-EES and 91.3% for PtCr-EES (P=.3), the survival free from revascularization was 95.2% vs 94.5% (P=.6) and the survival free from death, infarction, and revascularization was 90.6% vs 88%, respectively (P=.4). The incidence of definite or probable thrombosis was 1.3% for CoCr-EES and 0.66% for PtCr-EES (P=.9). No cases of longitudinal stent compression were observed.
CONCLUSIONS: The results of this all-comers trial do not show significant differences between CoCr-EES and PtCr-EES. However, the sample size is not powered to exclude potential differences between stents.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23549491

Source DB:  PubMed          Journal:  J Invasive Cardiol        ISSN: 1042-3931            Impact factor:   2.022


  1 in total

1.  One-year clinical outcomes of different coronary drug eluting stents-Data from a prospective registry.

Authors:  B K S Sastry; Krishna Reddy Nallamalla; Nirmal Kumar; Deepti Kodati; Rajeev Menon
Journal:  Indian Heart J       Date:  2018-05-17
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.