Literature DB >> 23545562

Liquid chromatography/tandem mass spectrometry method for quantitative estimation of polyethylene glycol 400 and its applications.

V Vijaya Bhaskar1, Anil Middha, Sudhir Tiwari, Savithiri Shivakumar.   

Abstract

A rapid sensitive and selective MRM based method for the determination of polyethylene glycol 400 (PEG 400) in rat plasma was developed using liquid chromatography/tandem mass spectrometry (LC-MS/MS). PEG 400 and telmisartan (Internal standard) were extracted from rat plasma with acetonitrile and analysed on C18 column (Waters Xbridge, 50×4.6 mm, 3.5 μm) with the mobile phase (A - 0.1% formic acid in water; B - methanol). A generic gradient method with a short run time of 3.5 min was developed for the analysis of PEG 400. A total of nine oligomers were identified for PEG 400. The most abundant ions corresponding to PEG 400 oligomers at m/z 327, 371, 432, 476, 520, 564, 608, 652 and 696 with daughter ion at m/z 89 were selected for multiple reaction monitoring (MRM) in electrospray mode of ionisation. Analyte peak area of the oligomers was summed up to calculate the plasma concentrations of total PEG 400. The standard curve was linear (0.9954) over the concentration range of 1.01-1013.40 μg/mL. The lower limit of quantitation for PEG 400 was 1.01 μg/mL using 50 μL plasma. The coefficient of variation and relative error for inter and intraassay at three QC levels were 2.31-13.34 and -7.99 to 0.37, respectively. The method was validated for various parameters such as extraction recovery, matrix effect, autosampler stability, benchtop stability, freeze thaw stability, long term stability and was proved to be consistent across three QC levels with overall %CV less than 15. The developed method was successfully applied to the absolute bioavailability study of PEG 400 in male Sprague Dawley rats. Plasma concentrations of PEG 400 was measured after administration through oral and intravenous routes in male Sprague Dawley rats at a dose of 3.38 g/kg. Pharmacokinetic (PK) parameters were characterised by performing the analysis using Phoenix Winnonlin software (v 6.3). PEG 400 has good oral bioavailability with mean absolute bioavailability of 47.23%. Plasma concentration profile/PK parameters of PEG 400 was established in both intravenous and oral routes, which helps to qualify the analytical batch of NCEs having spiky plasma concentration profiles/erratic results. Purity of the PEG 400 oligomers was estimated using ELSD detection. Differences in pharmacokinetics of oligomers was studied. It was found that with increase in molecular weight of the oligomer, a decrease in absolute bioavailability was observed. Crown
Copyright © 2013. Published by Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23545562     DOI: 10.1016/j.jchromb.2013.02.021

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  4 in total

1.  Liquid chromatography/tandem mass spectrometry method for quantitative estimation of solutol HS15 and its applications.

Authors:  V Vijaya Bhaskar; Anil Middha; Pratima Srivastava; Sriram Rajagopal
Journal:  J Pharm Anal       Date:  2014-09-16

2.  Simultaneous determination of kolliphor HS15 and miglyol 812 in microemulsion formulation by ultra-high performance liquid chromatography coupled with nano quantity analyte detector.

Authors:  Honggen Zhang; Zhenyu Wang; Oscar Liu
Journal:  J Pharm Anal       Date:  2015-11-19

Review 3.  Current status of in vivo bioanalysis of nano drug delivery systems.

Authors:  Tingting Wang; Di Zhang; Dong Sun; Jingkai Gu
Journal:  J Pharm Anal       Date:  2020-05-16

4.  Quantification of the actual composition of polymeric nanocapsules: a quality control analysis.

Authors:  Germán Berrecoso; José Crecente-Campo; María José Alonso
Journal:  Drug Deliv Transl Res       Date:  2022-03-18       Impact factor: 5.671

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.