Literature DB >> 23540250

Optimization of a lateral flow immunoassay for the ultrasensitive detection of aflatoxin M1 in milk.

Laura Anfossi1, Claudio Baggiani, Cristina Giovannoli, Flavia Biagioli, Gilda D'Arco, Gianfranco Giraudi.   

Abstract

A high sensitive immunoassay-based lateral flow device for semi-quantitatively determine aflatoxin M1 (AFM1) in milk was developed. Investigation and optimization of the competitor design and of the gold-labelling strategy allowed the attainment of the ultra-sensitive assessment of AFM1 contamination at nanograms per litre level (LOD 20 ng L(-1), IC50 99 ng L(-1)), as requested by European regulations. A one order of magnitude detectability enhancement in comparison to previously reported gold colloid immunochromatographic assays for this toxin was obtained. Direct detection of the target toxin in milk could be obtained by acquiring images of the strips and correlating intensities of the coloured lines with analyte concentrations. The one-step assay can be completed in 17 min, including a very simple and rapid sample preparation, which allowed the application of the assay to milk samples which differ in fat and protein contents. Although imprecise (mean RSD about 30%), the method proved to be accurate and sensitive enough to allow the correct attribution of sample as compliant or non-compliant according to EU legislation in force. Agreeing results to those of a reference ELISA were obtained on 40 milk samples by matrix-matched calibration in pasteurized milk.
Copyright © 2013 Elsevier B.V. All rights reserved.

Mesh:

Substances:

Year:  2013        PMID: 23540250     DOI: 10.1016/j.aca.2013.02.020

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  3 in total

1.  Orientational binding modes of reporters in a viral-nanoparticle lateral flow assay.

Authors:  Jinsu Kim; Ryan Poling-Skutvik; João R C Trabuco; Katerina Kourentzi; Richard C Willson; Jacinta C Conrad
Journal:  Analyst       Date:  2016-12-19       Impact factor: 4.616

Review 2.  Time-Resolved Fluorescence Immunochromatography Assay (TRFICA) for Aflatoxin: Aiming at Increasing Strip Method Sensitivity.

Authors:  Hui Li; Du Wang; Xiaoqian Tang; Wen Zhang; Qi Zhang; Peiwu Li
Journal:  Front Microbiol       Date:  2020-05-06       Impact factor: 5.640

3.  A Novel Graphene Oxide-Based Aptasensor for Amplified Fluorescent Detection of Aflatoxin M1 in Milk Powder.

Authors:  Xiaodong Guo; Fang Wen; Qinqin Qiao; Nan Zheng; Matthew Saive; Marie-Laure Fauconnier; Jiaqi Wang
Journal:  Sensors (Basel)       Date:  2019-09-05       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.