Literature DB >> 23539707

The three-dimensional morphometry of the odontoid peg and its impact on ventral screw osteosynthesis.

P Puchwein1, B Jester, B Freytag, K Tanzer, C Maizen, R Gumpert, W Pichler.   

Abstract

Ventral screw osteosynthesis is a common surgical method for treating fractures of the odontoid peg, but there is still no consensus about the number and diameter of the screws to be used. The purpose of this study was to develop a more accurate measurement technique for the morphometry of the odontoid peg (dens axis) and to provide a recommendation for ventral screw osteosynthesis. Images of the cervical spine of 44 Caucasian patients, taken with a 64-line CT scanner, were evaluated using the measuring software MIMICS. All measurements were performed by two independent observers. Intraclass correlation coefficients were used to measure inter-rater variability. The mean length of the odontoid peg was 39.76 mm (SD 2.68). The mean screw entry angle α was 59.45° (SD 3.45). The mean angle between the screw and the ventral border of C2 was 13.18° (SD 2.70), the maximum possible mean converging angle of two screws was 20.35° (SD 3.24). The measurements were obtained at the level of 66% of the total odontoid peg length and showed mean values of 8.36 mm (SD 0.84) for the inner diameter in the sagittal plane and 7.35 mm (SD 0.97) in the coronal plane. The mean outer diameter of the odontoid peg was 12.88 mm (SD 0.91) in the sagittal plane and 11.77 mm (SD 1.09) in the coronal plane. The results measured at the level of 90% of the total odontoid peg length were a mean of 6.12 mm (SD 1.14) for the sagittal inner diameter and 5.50 mm (SD 1.05) for the coronal inner diameter. The mean outer diameter of the odontoid peg was 11.10 mm (SD 1.0) in the sagittal plane and 10.00 mm (SD 1.07) in the coronal plane. In order to calculate the necessary screw length using 3.5 mm cannulated screws, 1.5 mm should be added to the measured odontoid peg length when anatomical reduction seems possible. The cross-section of the odontoid peg is not circular but slightly elliptical, with a 10% greater diameter in the sagittal plane. In the majority of cases (70.5%) the odontoid peg offers enough room for two 3.5 mm cannulated cortical screws.

Entities:  

Mesh:

Year:  2013        PMID: 23539707     DOI: 10.1302/0301-620X.95B4.30949

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  9 in total

Review 1.  Three-dimensional reconstructions in spine and screw trajectory simulation on 3D digital images: a step by step approach by using Mimics software.

Authors:  Dong Chen; Chun-Hui Chen; Li Tang; Kai Wang; Yu-Zhe Li; Kevin Phan; Ai-Min Wu
Journal:  J Spine Surg       Date:  2017-12

2.  Computerized Tomography-Based Morphometric Analysis of Odontoid in 100 Egyptian Patients.

Authors:  Nirmal D Patil; Mohammad Essam; Raafat Kamal Ragab; Hesham Elsaghir
Journal:  Int J Spine Surg       Date:  2020-02-29

3.  The radiological feature of anterior occiput-to-axis screw fixation as it guides the screw trajectory on 3D printed models: a feasibility study on 3D images and 3D printed models.

Authors:  Ai-Min Wu; Sheng Wang; Wan-Qing Weng; Zhen-Xuan Shao; Xin-Dong Yang; Jian-Shun Wang; Hua-Zi Xu; Yong-Long Chi
Journal:  Medicine (Baltimore)       Date:  2014-12       Impact factor: 1.889

4.  A novel computed method to reconstruct the bilateral digital interarticular channel of atlas and its use on the anterior upper cervical screw fixation.

Authors:  Ai-Min Wu; Wenhai Wang; Hui Xu; Zhong-Ke Lin; Xin-Dong Yang; Xiang-Yang Wang; Hua-Zi Xu; Yong-Long Chi
Journal:  PeerJ       Date:  2016-02-23       Impact factor: 2.984

Review 5.  The Dens: A Review of its Diverse Nomenclature and a Recommended Simplified Terminology.

Authors:  Jaspreet Johal; Christian Fisahn; Brittni Burgess; Marios Loukas; Jens Chapman; Rod J Oskouian; R Shane Tubbs
Journal:  Cureus       Date:  2017-01-17

6.  Morphometric parameters of the odontoid process of C2 vertebrae, in Indian population, a CT evaluation.

Authors:  Shankar Acharya; Manoj Kumar; Jay Deep Ghosh; Nitin Adsul; R S Chahal; K L Kalra
Journal:  Surg Neurol Int       Date:  2021-09-30

7.  The accuracy of a method for printing three-dimensional spinal models.

Authors:  Ai-Min Wu; Zhen-Xuan Shao; Jian-Shun Wang; Xin-Dong Yang; Wan-Qing Weng; Xiang-Yang Wang; Hua-Zi Xu; Yong-Long Chi; Zhong-Ke Lin
Journal:  PLoS One       Date:  2015-04-27       Impact factor: 3.240

8.  Percutaneous anterior C1/2 transarticular screw fixation: salvage of failed percutaneous odontoid screw fixation for odontoid fracture.

Authors:  Ai-Min Wu; Hai-Ming Jin; Zhong-Ke Lin; Yong-Long Chi; Xiang-Yang Wang
Journal:  J Orthop Surg Res       Date:  2017-09-29       Impact factor: 2.359

9.  Morphometric Evaluation of Craniocervical Junction by Magnetic Resonance Imaging Method.

Authors:  Mukadder Sunar; Samet Kapakin
Journal:  Asian J Neurosurg       Date:  2019 Jul-Sep
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.