Scapular notching and osteophyte formation after reverse shoulder replacement: Radiological analysis of implant position in male and female patients.

C P Roche1, Y Marczuk, T W Wright, P-H Flurin, S Grey, R Jones, H D Routman, G Gilot, J D Zuckerman.   

Abstract

This study provides recommendations on the position of the implant in reverse shoulder replacement in order to minimise scapular notching and osteophyte formation. Radiographs from 151 patients who underwent primary reverse shoulder replacement with a single prosthesis were analysed at a mean follow-up of 28.3 months (24 to 44) for notching, osteophytes, the position of the glenoid baseplate, the overhang of the glenosphere, and the prosthesis scapular neck angle (PSNA). A total of 20 patients (13.2%) had a notch (16 Grade 1 and four Grade 2) and 47 (31.1%) had an osteophyte. In patients without either notching or an osteophyte the baseplate was found to be positioned lower on the glenoid, with greater overhang of the glenosphere and a lower PSNA than those with notching and an osteophyte. Female patients had a higher rate of notching than males (13.3% vs 13.0%) but a lower rate of osteophyte formation (22.9% vs 50.0%), even though the baseplate was positioned significantly lower on the glenoid in females (p = 0.009) and each had a similar mean overhang of the glenosphere. Based on these findings we make recommendations on the placement of the implant in both male and female patients to avoid notching and osteophyte formation.

Entities:  

Mesh:

Year:  2013        PMID: 23539706     DOI: 10.1302/0301-620X.95B4.30442

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  12 in total

1.  Response to: Fuller et al., "Glenosphere disengagement in a reverse total shoulder arthroplasty with a non-Morse taper design".

Authors:  Lynn Crosby; Pierre-Henri Flurin; Thomas Wright; Joseph D Zuckerman
Journal:  Int Orthop       Date:  2015-04-07       Impact factor: 3.075

Review 2.  Reverse polarity shoulder replacement: Current concepts and review of literature.

Authors:  Ling Hong Lee; Aravind Desai
Journal:  World J Orthop       Date:  2014-07-18

3.  Clinical implications of scapular notching at 2 and 5-year follow-up after reverse total shoulder arthroplasty.

Authors:  Robert J Shelley; Mikalyn T DeFoor; Stephen A Parada; Lynn A Crosby
Journal:  J Orthop       Date:  2020-08-19

4.  Anatomical and reverse shoulder arthroplasty utilizing a single implant system with a platform stem: A prospective observational study with midterm follow-up.

Authors:  Lindsay Flynn; Matthew R Patrick; Christopher Roche; Joseph D Zuckerman; Pierre-Henri Flurin; Lynn Crosby; Richard Friedman; Thomas W Wright
Journal:  Shoulder Elbow       Date:  2019-04-10

5.  Treatment of proximal humeral fractures with reverse shoulder arthroplasty in elderly patients.

Authors:  C Iacobellis; A Berizzi; C Biz; A Camporese
Journal:  Musculoskelet Surg       Date:  2014-06-11

6.  Deltoid muscle volume affects clinical outcome of reverse total shoulder arthroplasty in patients with cuff tear arthropathy or irreparable cuff tears.

Authors:  Jong Pil Yoon; Anna Seo; Jeong Jun Kim; Chang-Hwa Lee; Seung-Hun Baek; Shin Yoon Kim; Eun Taek Jeong; Kyung-Soo Oh; Seok Won Chung
Journal:  PLoS One       Date:  2017-03-29       Impact factor: 3.240

Review 7.  The modern reverse shoulder arthroplasty and an updated systematic review for each complication: part I.

Authors:  Sarav S Shah; Benjamin T Gaal; Alexander M Roche; Surena Namdari; Brian M Grawe; Macy Lawler; Stewart Dalton; Joseph J King; Joshua Helmkamp; Grant E Garrigues; Thomas W Wright; Bradley S Schoch; Kyle Flik; Randall J Otto; Richard Jones; Andrew Jawa; Peter McCann; Joseph Abboud; Gabe Horneff; Glen Ross; Richard Friedman; Eric T Ricchetti; Douglas Boardman; Robert Z Tashjian; Lawrence V Gulotta
Journal:  JSES Int       Date:  2020-09-07

8.  Larger polyethylene glenospheres in reverse shoulder arthroplasty: are they safe?

Authors:  Carl W Jones; Matthew Barrett; John Erickson; Idah Chatindiara; Peter Poon
Journal:  JSES Int       Date:  2020-10-08

9.  Reversed shoulder arthroplasty with inversed bearing materials: 2-year clinical and radiographic results in 101 patients.

Authors:  Ulrich Irlenbusch; Max J Kääb; George Kohut; Jerome Proust; Falk Reuther; Thierry Joudet
Journal:  Arch Orthop Trauma Surg       Date:  2014-12-25       Impact factor: 3.067

10.  The influence of glenoid component position on scapular notching: a detailed radiographic analysis at midterm follow-up.

Authors:  Nicholas C Duethman; William R Aibinder; Ngoc Tram V Nguyen; Joaquin Sanchez-Sotelo
Journal:  JSES Int       Date:  2020-01-14
View more