Literature DB >> 23538845

Manifold benefits of choosing a minimally fluoroscopic catheter ablation approach.

Michela Casella1, Antonio Dello Russo, Gaetano Fassini, Daniele Andreini, Pasquale De Iuliis, Saima Mushtaq, Stefano Bartoletti, Stefania Riva, Claudio Tondo.   

Abstract

We report the case of a 14-year-old boy with ventricular preexcitation. A standard, fluoroscopy guided, ablation procedure was successfully performed in a postero-midseptal region with a total fluoroscopy time of about 45 min (2430 cGy.cm(2)). A few hours after the procedure, preexcitation reappeared. A second ablation procedure was scheduled using the EnSite NavX™ mapping system. During mapping along the tricuspid groove, preexcitation suddenly disappeared due to mechanical "bumping" of the accessory pathway and it did not recover over the next 30 min. As per our routine practice, the phase of geometry reconstruction has been continuously recorded by the system; thus, an off-line analysis allowed to pinpoint the site of earliest activation and the site of mechanical bumping, where radiofrequency obtained the accessory pathway ablation. The second procedure was performed without using fluoroscopy at all. Thanks to the geometry reconstruction, the procedure was completely successful thus avoiding a further rehospitalization.

Entities:  

Keywords:  Accessory pathway; Electroanatomical mapping; Radiation exposure; Radiofrequency ablation; Supraventricular arrhythmias

Year:  2013        PMID: 23538845      PMCID: PMC3609011          DOI: 10.4330/wjc.v5.i2.8

Source DB:  PubMed          Journal:  World J Cardiol


  3 in total

1.  Radiation safety.

Authors:  Stewart C Bushong; Richard L Morin
Journal:  J Am Coll Radiol       Date:  2004-02       Impact factor: 5.532

Review 2.  "Near-zero" fluoroscopic exposure in supraventricular arrhythmia ablation using the EnSite NavX™ mapping system: personal experience and review of the literature.

Authors:  Michela Casella; Gemma Pelargonio; Antonio Dello Russo; Stefania Riva; Stefano Bartoletti; Pasquale Santangeli; Antonio Scarà; Tommaso Sanna; Riccardo Proietti; Luigi Di Biase; G Joseph Gallinghouse; Maria Lucia Narducci; Luigi Sisto; Fulvio Bellocci; Andrea Natale; Claudio Tondo
Journal:  J Interv Card Electrophysiol       Date:  2011-03-02       Impact factor: 1.900

3.  Right ventricular substrate mapping using the Ensite Navx system: Accuracy of high-density voltage map obtained by automatic point acquisition during geometry reconstruction.

Authors:  Michela Casella; Francesco Perna; Antonio Dello Russo; Gemma Pelargonio; Stefano Bartoletti; Annalisa Ricco; Tommaso Sanna; Maurizio Pieroni; Giovanni Forleo; Augusto Pappalardo; Luigi Di Biase; Luigi Natale; Fulvio Bellocci; Paolo Zecchi; Andrea Natale; Claudio Tondo
Journal:  Heart Rhythm       Date:  2009-07-22       Impact factor: 6.343

  3 in total
  1 in total

1.  Near zerO fluoroscopic exPosure during catheter ablAtion of supRavenTricular arrhYthmias: the NO-PARTY multicentre randomized trial.

Authors:  Michela Casella; Antonio Dello Russo; Gemma Pelargonio; Maurizio Del Greco; Gianluca Zingarini; Marcello Piacenti; Andrea Di Cori; Victor Casula; Massimiliano Marini; Francesca Pizzamiglio; Martina Zucchetti; Stefania Riva; Eleonora Russo; Maria Lucia Narducci; Ezio Soldati; Luca Panchetti; Umberto Startari; Gianluigi Bencardino; Francesco Perna; Pasquale Santangeli; Luigi Di Biase; Fabrizio Cichocki; Giovanni Fattore; Mariagrazia Bongiorni; Eugenio Picano; Andrea Natale; Claudio Tondo
Journal:  Europace       Date:  2015-11-10       Impact factor: 5.214

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.