Literature DB >> 23538059

Associations of iris structural measurements in a Chinese population: the Singapore Chinese Eye Study.

Chelvin C Sng1, John C Allen, Monisha E Nongpiur, Li-Lian Foo, Yingfeng Zheng, Carol Y Cheung, Mingguang He, David S Friedman, Tien Y Wong, Tin Aung.   

Abstract

PURPOSE: We determined the ocular biometric and demographic factors associated with iris parameters in Singaporean Chinese persons from a population-based sample.
METHODS: Subjects were participants in the Singapore Chinese Eye Study, a population-based cross-sectional study of eye disease. Anterior segment optical coherence tomography images were analyzed using customized software to measure iris thickness at 750 μm from the scleral spur (IT750), iris area (I-Area), and iris curvature (I-Curv). Regression analyses were performed to assess the association between iris measurements with a range of demographic and ocular variables. The contribution of each independent variable to the iris parameter of interest was determined sequentially using a stepwise selection algorithm.
RESULTS: We included 1473 participants with a mean age of 57.7 + 8.68 years, and 50.6% were men. The mean IT750, I-Area, and I-Curv were 0.46 ± 0.10 mm, 1.49 ± 0.24 mm(2), and 0.25 ± 0.13 mm, respectively. Statistical regression models, including a range of demographic and ocular parameters, explained 59.3%, 41.9%, and 34.3% of the variability in I-Curv, IT750, and I-Area, respectively. Angle opening distance at 750 μm from the scleral spur (AOD750) was the single factor associated most strongly with I-Curv, and explained 46.6% of its variation.
CONCLUSIONS: A significant proportion of the variation in iris area, curvature, and thickness was not explained by other ocular and demographic parameters. Iris curvature was associated strongly with angle width, and of all parameters investigated, AOD750 was most highly correlated with iris curvature.

Entities:  

Mesh:

Year:  2013        PMID: 23538059     DOI: 10.1167/iovs.12-11250

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  10 in total

1.  Comparison of dynamic changes in anterior ocular structures examined with anterior segment optical coherence tomography in a cohort of various origins.

Authors:  Fiona E Seager; Joan L Jefferys; Harry A Quigley
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-03-19       Impact factor: 4.799

2.  Novel Automated Approach to Predict the Outcome of Laser Peripheral Iridotomy for Primary Angle Closure Suspect Eyes Using Anterior Segment Optical Coherence Tomography.

Authors:  Victor Koh; Issac Niwas Swamidoss; Maria Cecilia D Aquino; Paul T Chew; Chelvin Sng
Journal:  J Med Syst       Date:  2018-04-27       Impact factor: 4.460

3.  Effects of lens extraction versus laser peripheral iridotomy on anterior segment morphology in primary angle closure suspect.

Authors:  Chenxi Yan; Ying Han; Yibo Yu; Wei Wang; Danni Lyu; Yizhen Tang; Ke Yao
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-05-11       Impact factor: 3.117

4.  Comparative Study of the Effects of 1% Atropine on the Anterior Segment.

Authors:  Yue Zhou; Xiao Bo Huang; Qi Cai; Jun Jie Li; Yao Jia Xiong; Ye Xun Gong; Li Wei Lin; Yan Zhu; Zhi Min Sun
Journal:  J Ophthalmol       Date:  2020-09-28       Impact factor: 1.909

5.  Assessment of Anterior Segment Measurements with Swept Source Optical Coherence Tomography before and after Ab Interno Trabeculotomy (Trabectome) Surgery.

Authors:  Handan Akil; Ping Huang; Vikas Chopra; Brian Francis
Journal:  J Ophthalmol       Date:  2016-10-03       Impact factor: 1.909

6.  Qualitative evaluation of anterior segment in angle closure disease using anterior segment optical coherence tomography.

Authors:  Sasan Moghimi; Rebecca Chen; Nikoo Hamzeh; Nassim Khatibi; Shan C Lin
Journal:  J Curr Ophthalmol       Date:  2016-07-12

7.  Differences between fellow eyes of acute and chronic primary angle closure (glaucoma): An ultrasound biomicroscopy quantitative study.

Authors:  Mengwei Li; Yuhong Chen; Xiaoxiao Chen; Wenqing Zhu; Xueli Chen; Xiaolei Wang; Yuan Fang; Xiangmei Kong; Yi Dai; Junyi Chen; Xinghuai Sun
Journal:  PLoS One       Date:  2018-02-15       Impact factor: 3.240

8.  Determination of iris thickness development in children using swept-source anterior-segment optical coherence tomography.

Authors:  Shunsuke Nakakura; Yuki Nagata; Yukiko Shimizu; Akiko Kawai; Hitoshi Tabuchi; Yoshiaki Kiuchi
Journal:  PLoS One       Date:  2019-05-28       Impact factor: 3.240

9.  Association of Iris Structural Measurements with Corneal Biomechanics in Myopic Eyes.

Authors:  Lin Fu; Yufeng Ye; Xu Jia; Yunjie Zhang; Xiaoyu Chen; Hengli Lian; Weihua Yang; Qi Dai
Journal:  Dis Markers       Date:  2021-12-31       Impact factor: 3.434

10.  Anterior Chamber Measurements in Healthy Children: A Cross-Sectional Study Using Optical Coherence Tomography.

Authors:  Budor S A Edawaji; Irene Gottlob; Frank A Proudlock
Journal:  Transl Vis Sci Technol       Date:  2021-05-03       Impact factor: 3.283

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.