Literature DB >> 23535914

A method for DNA-based detection of E. coli O157:H7 in a proteinous background using piezoelectric-excited cantilever sensors.

Kishan Rijal1, Raj Mutharasan.   

Abstract

We show for the first time the detection of ~700 E. coli O157:H7 (EC) in both buffer and proteinous sample (beef wash) using the virulent gene stx2 as a sensing molecule immobilized on piezoelectric-excited millimeter cantilever (PEMC) sensors without a sample preparation step. Genomic DNA of EC suspended in buffer or beef wash was extracted using a 30-minute procedure, or using a commercial extraction kit, and then was exposed to the sensor immobilized with a 19-mer probe that is complement to stx2 gene. As hybridization occurred, the resonant frequency of the cantilever sensor decreased due to the increased attached mass indicating the presence of stx2 gene in the sample. Wild strain JM101 subjected to the same preparation and procedure did not induce a hybridization response, nor did the genomic extract of EC with a bare sensor. PEMC sensor responses to diluted genomic extracts indicate that a much lower concentration of 700 cells is detectable. In order to compare the results with antibody-based detection, samples with EC at 2500 cells per mL were exposed to antibody-immobilized PEMC sensors which gave reproducible responses confirming previous experiments with such samples.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23535914     DOI: 10.1039/c3an36814a

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  6 in total

Review 1.  Gene Specific DNA Sensors for Diagnosis of Pathogenic Infections.

Authors:  Manali Datta; Dignya Desai; Ashok Kumar
Journal:  Indian J Microbiol       Date:  2017-04-25       Impact factor: 2.461

Review 2.  Hybrid integrated label-free chemical and biological sensors.

Authors:  Simin Mehrabani; Ashley J Maker; Andrea M Armani
Journal:  Sensors (Basel)       Date:  2014-03-26       Impact factor: 3.576

Review 3.  Overview of Piezoelectric Biosensors, Immunosensors and DNA Sensors and Their Applications.

Authors:  Miroslav Pohanka
Journal:  Materials (Basel)       Date:  2018-03-19       Impact factor: 3.623

4.  Influence of Graphene Oxide Concentration when Fabricating an Electrochemical Biosensor for DNA Detection.

Authors:  Elena A Chiticaru; Luisa Pilan; Celina-Maria Damian; Eugeniu Vasile; Jorge S Burns; Mariana Ioniţă
Journal:  Biosensors (Basel)       Date:  2019-09-26

5.  PCR-Independent Detection of Bacterial Species-Specific 16S rRNA at 10 fM by a Pore-Blockage Sensor.

Authors:  Leyla Esfandiari; Siqing Wang; Siqi Wang; Anisha Banda; Michael Lorenzini; Gayane Kocharyan; Harold G Monbouquette; Jacob J Schmidt
Journal:  Biosensors (Basel)       Date:  2016-07-22

6.  Development of Organic-Inorganic Hybrid Optical Gas Sensors for the Non-Invasive Monitoring of Pathogenic Bacteria.

Authors:  Sumana Kladsomboon; Chadinee Thippakorn; Thara Seesaard
Journal:  Sensors (Basel)       Date:  2018-09-21       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.