Literature DB >> 23534767

Clinical study of tumor angiogenesis and perfusion imaging using multi-slice spiral computed tomography for breast cancer.

Na Xu1, Zhen Lei, Xiao-Long Li, Jun Zhang, Chen Li, Guo-Quan Feng, Di-Nuo Li, Jing-Yi Liu, Qiang Wei, Ting-Ting Bian, Tian-Yu Zou.   

Abstract

OBJECTIVES: To explore the correlation between multi-slice spiral CT (MSCT) perfusion parameters and the expression of vascular endothelial growth factor (VEGF) as well as matrix metalloproteinase-2 (MMP- 2) in breast cancer.
METHODS: Forty five breast cancer patients and 16 patients with benign breast tumor, both confirmed by pathology examination, were enrolled. All underwent MSCT perfusion imaging to obtain perfusion maps and data for parameters including blood flow (BF), blood volume (BV) and permeability surface (PS). Cancer patients did not receive treatment prior to surgery. The expression of VEGF and MMP-2 were examined with both immunohistochemistry and Western blotting.
RESULTS: The levels of VEGF and MMP-2 by immunohistochemistry were significantly higher in the breast cancer group (P < 0.01) than the benign tumor group. Relative OD values from Western blotting were also higher in cancer cases (P < 0.05). Similarly, the mean MSCT perfusion parameters (BF, BV, PS) were significantly higher in the breast cancer group (P < 0.01), BF and BV positively correlating with VEGF expression (r = 0.878 and 0.809 respectively, P < 0.01); PS and VEGF and MMP-2 expression were also positively correlated (r= 0.860, 0.786 respectively, P < 0.01).
CONCLUSION: There is a correlation between breast cancer MSCT perfusion parameters and VEGF andMMP-2 expression, which might be useful for detection of breast lesions, qualitative diagnosis of breast cancer, and evaluation of breast cancer treatment.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23534767     DOI: 10.7314/apjcp.2013.14.1.429

Source DB:  PubMed          Journal:  Asian Pac J Cancer Prev        ISSN: 1513-7368


  5 in total

1.  Development and validation of a segmentation-free polyenergetic algorithm for dynamic perfusion computed tomography.

Authors:  Yuan Lin; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2016-08-23

2.  Cone beam CT for determining breast cancer margin: an initial experience and its comparison with mammography and specimen radiograph.

Authors:  Juan Yao; Chris Shaw; C J Lai; John Rong; Jian Wang; Wenya Liu
Journal:  Int J Clin Exp Med       Date:  2015-09-15

3.  The use of sequential X-ray, CT and MRI in the preoperative evaluation of breast-conserving surgery.

Authors:  Huiyu Zhang; Hongna Tan; Jianbo Gao; Yan Wei; Zhan Yu; Yan Zhou
Journal:  Exp Ther Med       Date:  2016-06-13       Impact factor: 2.447

4.  Plasma levels and diagnostic utility of VEGF, MMP-9, and TIMP-1 in the diagnosis of patients with breast cancer.

Authors:  Sławomir Ławicki; Monika Zajkowska; Edyta Katarzyna Głażewska; Grażyna Ewa Będkowska; Maciej Szmitkowski
Journal:  Onco Targets Ther       Date:  2016-02-24       Impact factor: 4.147

5.  Evaluation of Multislice Spiral Computed Tomography Perfusion Imaging for the Efficacy of Preoperative Concurrent Chemoradiotherapy in Middle-aged and Elderly Patients with Locally Advanced Gastric Cancer.

Authors:  Jian-Xiao Liang; Xiu-Juan Bi; Xiao-Mei Li; Zhen-Li Gao; Feng Suo; En-Gang Cui; Hong-Fu Li; Hai-Lian Lv
Journal:  Med Sci Monit       Date:  2018-01-12
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.