Literature DB >> 23532782

Using metal complex ion-molecule reactions in a miniature rectilinear ion trap mass spectrometer to detect chemical warfare agents.

Adam M Graichen1, Richard W Vachet.   

Abstract

The gas-phase reactions of a series of coordinatively unsaturated [Ni(L)n](y+) complexes, where L is a nitrogen-containing ligand, with chemical warfare agent (CWA) simulants in a miniature rectilinear ion trap mass spectrometer were investigated as part of a new approach to detect CWAs. Results show that upon entering the vacuum system via a poly(dimethylsiloxane) (PDMS) membrane introduction, low concentrations of several CWA simulants, including dipropyl sulfide (simulant for mustard gas), acetonitrile (simulant for the nerve agent tabun), and diethyl phosphite (simulant for nerve agents sarin, soman, tabun, and VX), can react with metal complex ions generated by electrospray ionization (ESI), thereby providing a sensitive means of detecting these compounds. The [Ni(L)n](2+) complexes are found to be particularly reactive with the simulants of mustard gas and tabun, allowing their detection at low parts-per-billion (ppb) levels. These detection limits are well below reported exposure limits for these CWAs, which indicates the applicability of this new approach, and are about two orders of magnitude lower than electron ionization detection limits on the same mass spectrometer. The use of coordinatively unsaturated metal complexes as reagent ions offers the possibility of further tuning the ion-molecule chemistry so that desired compounds can be detected selectively or at even lower concentrations.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23532782     DOI: 10.1007/s13361-013-0592-2

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  22 in total

1.  Screening for sarin in air and water by solid-phase microextraction-gas chromatography-mass spectrometry.

Authors:  J F Schneider; A S Boparai; L L Reed
Journal:  J Chromatogr Sci       Date:  2001-10       Impact factor: 1.618

2.  Miniaturized mass-selective detector with atmospheric pressure chemical ionization.

Authors:  A L Makas; M L Troshkov; A S Kudryavtsev; V M Lunin
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2004-02-05       Impact factor: 3.205

3.  Analytical chemistry at the forefront of homeland defense.

Authors:  Wilder D Smith
Journal:  Anal Chem       Date:  2002-09-01       Impact factor: 6.986

4.  Direct monitoring of toxic compounds in air using a portable mass spectrometer.

Authors:  Christopher C Mulligan; Dina R Justes; Robert J Noll; Nathaniel L Sanders; Brian C Laughlin; R Graham Cooks
Journal:  Analyst       Date:  2006-02-28       Impact factor: 4.616

5.  Ion/molecule reactions in a miniature RIT mass spectrometer.

Authors:  Huanwen Chen; Ruifeng Xu; Hao Chen; R Graham Cooks; Zheng Ouyang
Journal:  J Mass Spectrom       Date:  2005-11       Impact factor: 1.982

6.  Ultrasonic cleavage of thioethers.

Authors:  Zhilin Wu; Bernd Ondruschka; Annegret Stark
Journal:  J Phys Chem A       Date:  2005-04-28       Impact factor: 2.781

7.  Facility monitoring of chemical warfare agent simulants in air using an automated, field-deployable, miniature mass spectrometer.

Authors:  Jonell N Smith; Robert J Noll; R Graham Cooks
Journal:  Rapid Commun Mass Spectrom       Date:  2011-05-30       Impact factor: 2.419

8.  Formation of [b(n) + 17 + Ag]+ product ions from Ag+ cationized native and acetylated peptides.

Authors:  V Anbalagan; B A Perera; A T M Silva; A L Gallardo; M Barber; J M Barr; S M Terkarli; E R Talaty; M J Van Stipdonk
Journal:  J Mass Spectrom       Date:  2002-09       Impact factor: 1.982

9.  Ion-molecule reactions of gas-phase chromium oxyanions. CrxOyHz-+ O2.

Authors:  A K Gianotto; B D M Hodges; P de B Harrington; A D Appelhans; J E Olson; G S Groenewold
Journal:  J Am Soc Mass Spectrom       Date:  2003-10       Impact factor: 3.109

10.  Trace determination of volatile sulfur compounds by solid-phase microextraction and GC-MS.

Authors:  Annika T Nielsen; Susanne Jonsson
Journal:  Analyst       Date:  2002-08       Impact factor: 4.616

View more
  2 in total

Review 1.  Miniature and Fieldable Mass Spectrometers: Recent Advances.

Authors:  Dalton T Snyder; Christopher J Pulliam; Zheng Ouyang; R Graham Cooks
Journal:  Anal Chem       Date:  2015-10-21       Impact factor: 6.986

2.  Improved Miniaturized Linear Ion Trap Mass Spectrometer Using Lithographically Patterned Plates and Tapered Ejection Slit.

Authors:  Yuan Tian; Trevor K Decker; Joshua S McClellan; Linsey Bennett; Ailin Li; Abraham De la Cruz; Derek Andrews; Stephen A Lammert; Aaron R Hawkins; Daniel E Austin
Journal:  J Am Soc Mass Spectrom       Date:  2017-08-23       Impact factor: 3.109

  2 in total