Literature DB >> 23532527

Spectrophotometric retinal oximetry in pigs.

Sindri Traustason1, Jens F Kiilgaard, Robert A Karlsson, Sveinn H Hardarson, Einar Stefansson, Morten la Cour.   

Abstract

PURPOSE: To assess the validity of spectrophotometric retinal oximetry by comparison to blood gas analysis and intravitreal measurements of partial pressure of oxygen (pO(2)).
METHODS: Female domestic pigs were used for all experiments (n = 8). Oxygen fraction in inspired air was changed using a mixture of room air, pure oxygen, and pure nitrogen, ranging from 5% to 100% oxygen. Femoral arterial blood gas analysis and retinal oximetry were performed at each level of inspiratory oxygen fraction. Retinal oximetry was performed using a commercial instrument, the Oxymap Retinal Oximeter T1. The device simultaneously acquires images at two wavelengths (570 nm and 600 nm), and specialized software automatically detects retinal blood vessels. In three pigs, invasive pO(2) measurements were performed after the initial noninvasive measurements.
RESULTS: Comparison of femoral arterial oxygen saturation and the optical density ratio over retinal arteries revealed an approximately linear relationship (R(2) = 0.74, P = 3.4 × 10(-9)). In order to test the validity of applying the arterial calibration to veins, we compared noninvasive oximetry measurements to invasive pO2 measurements in three pigs. This relationship was approximately linear (R(2) = 0.45, P = 0.04).
CONCLUSIONS: Noninvasive spectrophotometric oximetry is sensitive to changes in oxygen saturation in pigs and correlated with intravitreal pO(2) measurements and with femoral artery pO(2). Pigs present a higher intraindividual variability in retinal oxygen saturation and a lower overall saturation than do humans. The difference between porcine and human eyes makes direct comparisons of measurements difficult.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23532527     DOI: 10.1167/iovs.12-11284

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  7 in total

1.  In vivo photoacoustic tomography of myoglobin oxygen saturation.

Authors:  Li Lin; Junjie Yao; Lei Li; Lihong V Wang
Journal:  J Biomed Opt       Date:  2016-06       Impact factor: 3.170

Review 2.  Retinal oxygen: from animals to humans.

Authors:  Robert A Linsenmeier; Hao F Zhang
Journal:  Prog Retin Eye Res       Date:  2017-01-18       Impact factor: 21.198

3.  Molecular probes for imaging of hypoxia in the retina.

Authors:  Stephanie M Evans; Kwangho Kim; Chauca E Moore; Md Imam Uddin; Megan E Capozzi; Jason R Craft; Gary A Sulikowski; Ashwath Jayagopal
Journal:  Bioconjug Chem       Date:  2014-10-09       Impact factor: 4.774

4.  Retinal Oximetry in a Healthy Japanese Population.

Authors:  Yuki Nakano; Takeru Shimazaki; Nobuko Kobayashi; Yukiko Miyoshi; Aoi Ono; Mamoru Kobayashi; Chieko Shiragami; Kazuyuki Hirooka; Akitaka Tsujikawa
Journal:  PLoS One       Date:  2016-07-19       Impact factor: 3.240

5.  The effect of vitreomacular and cataract surgery on oxygen saturation in retinal vessels.

Authors:  Yuki Nakano; Koichiro Manabe; Rie Osaka; Yukari Takasago; Aoi Ono; Mamoru Kobayashi; Tomoyoshi Fujita; Chieko Shiragami; Kazuyuki Hirooka; Akitaka Tsujikawa
Journal:  Clin Ophthalmol       Date:  2017-04-21

6.  Retinal oximetry measures systemic hypoxia in central nervous system vessels in chronic obstructive pulmonary disease.

Authors:  Thorunn Scheving Eliasdottir; David Bragason; Sveinn Hakon Hardarson; Charles Vacchiano; Thorarinn Gislason; Jona Valgerdur Kristjansdottir; Gudrun Kristjansdottir; Einar Stefánsson
Journal:  PLoS One       Date:  2017-03-22       Impact factor: 3.240

7.  A combined method to quantify the retinal metabolic rate of oxygen using photoacoustic ophthalmoscopy and optical coherence tomography.

Authors:  Wei Song; Qing Wei; Wenzhong Liu; Tan Liu; Ji Yi; Nader Sheibani; Amani A Fawzi; Robert A Linsenmeier; Shuliang Jiao; Hao F Zhang
Journal:  Sci Rep       Date:  2014-10-06       Impact factor: 4.379

  7 in total