OBJECTIVES: To evaluate the outcomes of hybrid endovascular repair for aortic arch pathology.
METHODS: This study was a retrospective analysis involving patients who underwent hybrid endovascular repair for aortic arch pathologies.
RESULTS: Twenty-one patients (16 men; mean age, 64.7 ± 16.2 years) with aortic arch pathologies were treated by hybrid endovascular repair. The indications for treatment included increased aneurysm size in 16 cases (71.4%), rupture or impending aneurysmal rupture in 5 cases (23.8%), and rapid growth of aortic dissection (≥ 10 mm/y) in 1 case (4.8%). Supra-aortic vessel transposition and stent-graft implantation were achieved in all cases. Two types of stent-graft was used, as follows: the Seal thoracic stent-graft in 14 patients (66.7%); and the Valiant stent grafts in 7 patients (33.3%). Perioperative complications affected 5 patients (23.8%), as follows: bleeding (n = 4, 19.0%); stroke (n = 3, 14.3%); renal failure (n = 2, 9.5%); vascular injury (n = 1, 4.8%), and respiratory failure (n = 1, 4.8%). Two patients died within 30 days (9.5%). Technical success was achieved in 15 patients (71.5%). Early endoleaks were noted in 4 patients (19.0%). One patient died during follow-up (mean, 21.3 ± 11.6 months) due to a de novo intramural hematoma. Persistent early endoleaks were noted in 4 patients (19.0%); 2 of the 4 patients were successfully managed with implantation of additional stent-grafts. No late onset endoleaks were noted. The death-free survival and reintervention-free survival rates during follow-up were 85.7% and 90.5%, respectively.
CONCLUSION: Hybrid treatment with supra-aortic vessel transposition and endovascular repair may be an option in frail patients in who open procedures is too risky.
© 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  aortic arch pathology; hybrid endovascular repair; stent-graft; supra-aortic vessel transposition

Mesh:

Year:  2013        PMID: 23529847     DOI: 10.1002/ccd.24384

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  1 in total

1.  Endovascular repair of a leaking aortic-arch pseudoaneurysm using graft stent combined with chimney protection to left common carotid artery: Case report and review of literature.

Authors:  Raneem Fallatah; Abdelfatah A Elasfar; Shadha Alzubaidi; Mazen Alraddadi; Reda Abuelatta
Journal:  J Saudi Heart Assoc       Date:  2017-10-21
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.