Literature DB >> 23527359

Marginal bone levels and soft tissue conditions around single-tooth implants with a scalloped neck design: results of a prospective 3-year study.

Ameen Khraisat1, Anja Zembic, Ronald E Jung, Christoph H F Hammerle.   

Abstract

PURPOSE: Scalloped implants were developed to better maintain marginal bone. Therefore, this study evaluated marginal bone levels (MBLs) and soft tissue around single implants with scalloped necks in the esthetic zone prospectively over a 3-year period. MBLs were compared to those of conventional flat-platform implants at 1 and 3 years.
MATERIALS AND METHODS: Patients received anterior single-tooth implants and were divided into two groups; the test group included implants with a scalloped neck design and the control group included conventional rough-surface implants with external hex. MBLs were compared radiographically at 1 and 3 years after crown insertion. For the test group, soft and hard tissue assessments were made at six different time points, beginning at abutment connection. Mesial and distal interproximal papillae and probing depths were assessed clinically. Data were analyzed with the Student t test and repeated measures analysis of variance on ranks (P < .05).
RESULTS: Twenty-four patients (17 men, 7 women) took part; each group included 12 implants. The test group had significantly more marginal bone resorption than the control group at each time point (P < .001). With respect to changes in MBL values over time, a significant difference was detected between groups mesially (P < .001) but not distally. Statistical analyses demonstrated obvious significant increases with time (P < .001) in bone resorption and mesial papilla index. A significant increase over time in probing depths was demonstrated distally (P = .003) but not mesially.
CONCLUSIONS: The scalloped implant did not stabilize interproximal bone remodeling and caused more bone loss than conventional implants. Soft tissue levels were not maintained around the scalloped implants.

Entities:  

Mesh:

Year:  2013        PMID: 23527359     DOI: 10.11607/jomi.2544

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  4 in total

Review 1.  Scalloped Implant-Abutment Connection Compared to Conventional Flat Implant-Abutment Connection: a Systematic Review and Meta-Analysis.

Authors:  Thomas Starch-Jensen; Ann-Eva Christensen; Henning Lorenzen
Journal:  J Oral Maxillofac Res       Date:  2017-03-31

Review 2.  Survival and Success Rates of Different Shoulder Designs: A Systematic Review of the Literature.

Authors:  Marco Tallarico; Marco Caneva; Silvio Mario Meloni; Erta Xhanari; Yuki Omori; Luigi Canullo
Journal:  Int J Dent       Date:  2018-04-26

3.  A 4 Year Human, Randomized, Radiographic Study of Scalloped versus Non-Scalloped Cemented Implants.

Authors:  Bruna Sinjari; Gianmaria D'Addazio; Manlio Santilli; Barbara D'Avanzo; Imena Rexhepi; Antonio Scarano; Tonino Traini; Maurizio Piattelli; Sergio Caputi
Journal:  Materials (Basel)       Date:  2020-05-10       Impact factor: 3.623

4.  Radiological Outcomes of Bone-Level and Tissue-Level Dental Implants: Systematic Review.

Authors:  Saverio Cosola; Simone Marconcini; Michela Boccuzzi; Giovanni Battista Menchini Fabris; Ugo Covani; Miguel Peñarrocha-Diago; David Peñarrocha-Oltra
Journal:  Int J Environ Res Public Health       Date:  2020-09-22       Impact factor: 3.390

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.