Evaluation of a morphological filter in mean cardiac output determination: application to left ventricular assist devices.

Michael Charles Stevens1, Andrew P Bradley, Stephen J Wilson, David Glen Mason.   

Abstract

A morphological filter (MF) is presented for the determination of beat-to-beat mean rotary left ventricular assist device (LVAD) flow rate, measured using an implanted flow probe. The performance of this non-linear filter was assessed using LVAD flow rate (QLVAD) data sets obtained from in silico and in vivo sources. The MF was compared with a third-order Butterworth filter (BWF) and a 10-s moving average filter (MAF). Performance was assessed by calculating the response time and steady state error across a range of heart rates and levels of noise. The response time of the MF was 3.5 times faster than the MAF, 0.5 s slower than the BWF, and had a steady state error of 2.61 %. It completely removed pulsatile signal components caused by residual ventricular function, and tracked sharp transient changes in QLVAD better than the BWF. The use of a two-stage MF improved the noise immunity compared to the single-stage MF. This study showed that the good performance characteristics of the non-linear MF make it a more suitable candidate for embedded real-time processing of QLVAD than linear filters.

Mesh:

Year:  2013        PMID: 23526415     DOI: 10.1007/s11517-013-1061-6

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  7 in total

1.  ECG signal conditioning by morphological filtering.

Authors:  Yan Sun; Kap Chan; Shankar Muthu Krishnan
Journal:  Comput Biol Med       Date:  2002-11       Impact factor: 4.589

2.  Development of a reliable automatic speed control system for rotary blood pumps.

Authors:  Michael Vollkron; Heinrich Schima; Leopold Huber; Robert Benkowski; Gino Morello; Georg Wieselthaler
Journal:  J Heart Lung Transplant       Date:  2005-11       Impact factor: 10.247

3.  Impulsive noise suppression and background normalization of electrocardiogram signals using morphological operators.

Authors:  C H Chu; E J Delp
Journal:  IEEE Trans Biomed Eng       Date:  1989-02       Impact factor: 4.538

Review 4.  Software QRS detection in ambulatory monitoring--a review.

Authors:  O Pahlm; L Sórnmo
Journal:  Med Biol Eng Comput       Date:  1984-07       Impact factor: 2.602

5.  Clinical experience with the MicroMed DeBakey ventricular assist device.

Authors:  G P Noon; D L Morley; S Irwin; S V Abdelsayed; R J Benkowski; B E Lynch
Journal:  Ann Thorac Surg       Date:  2001-03       Impact factor: 4.330

6.  Interaction of the cardiovascular system with an implanted rotary assist device: simulation study with a refined computer model.

Authors:  Michael Vollkron; Heinrich Schima; Leopold Huber; Georg Wieselthaler
Journal:  Artif Organs       Date:  2002-04       Impact factor: 3.094

7.  Parameter-optimized model of cardiovascular-rotary blood pump interactions.

Authors:  Einly Lim; Socrates Dokos; Shaun L Cloherty; Robert F Salamonsen; David G Mason; John A Reizes; Nigel H Lovell
Journal:  IEEE Trans Biomed Eng       Date:  2009-09-18       Impact factor: 4.538

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.