Literature DB >> 23523325

Real-time tumor tracking in the lung using an electromagnetic tracking system.

Amish P Shah1, Patrick A Kupelian, Benjamin J Waghorn, Twyla R Willoughby, Justin M Rineer, Rafael R Mañon, Mark A Vollenweider, Sanford L Meeks.   

Abstract

PURPOSE: To describe the first use of the commercially available Calypso 4D Localization System in the lung. METHODS AND MATERIALS: Under an institutional review board-approved protocol and an investigational device exemption from the US Food and Drug Administration, the Calypso system was used with nonclinical methods to acquire real-time 4-dimensional lung tumor tracks for 7 lung cancer patients. The aims of the study were to investigate (1) the potential for bronchoscopic implantation; (2) the stability of smooth-surface beacon transponders (transponders) after implantation; and (3) the ability to acquire tracking information within the lung. Electromagnetic tracking was not used for any clinical decision making and could only be performed before any radiation delivery in a research setting. All motion tracks for each patient were reviewed, and values of the average displacement, amplitude of motion, period, and associated correlation to a sinusoidal model (R(2)) were tabulated for all 42 tracks.
RESULTS: For all 7 patients at least 1 transponder was successfully implanted. To assist in securing the transponder at the tumor site, it was necessary to implant a secondary fiducial for most transponders owing to the transponder's smooth surface. For 3 patients, insertion into the lung proved difficult, with only 1 transponder remaining fixed during implantation. One patient developed a pneumothorax after implantation of the secondary fiducial. Once implanted, 13 of 14 transponders remained stable within the lung and were successfully tracked with the tracking system.
CONCLUSIONS: Our initial experience with electromagnetic guidance within the lung demonstrates that transponder implantation and tracking is achievable though not clinically available. This research investigation proved that lung tumor motion exhibits large variations from fraction to fraction within a single patient and that improvements to both transponder and tracking system are still necessary to create a clinical daily-use system to assist with actual lung radiation therapy.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23523325     DOI: 10.1016/j.ijrobp.2012.12.030

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  19 in total

1.  Intra- and Inter-Fractional Variation Prediction of Lung Tumors Using Fuzzy Deep Learning.

Authors:  Seonyeong Park; Suk Jin Lee; Elisabeth Weiss; Yuichi Motai
Journal:  IEEE J Transl Eng Health Med       Date:  2016-01-08       Impact factor: 3.316

2.  Can bronchoscopically implanted anchored electromagnetic transponders be used to monitor tumor position and lung inflation during deep inspiration breath-hold lung radiotherapy?

Authors:  Wendy Harris; Ellen Yorke; Henry Li; Christian Czmielewski; Mohit Chawla; Robert P Lee; Alexandra Hotca-Cho; Dominique McKnight; Andreas Rimner; D Michael Lovelock
Journal:  Med Phys       Date:  2022-03-03       Impact factor: 4.071

3.  The markerless lung target tracking AAPM Grand Challenge (MATCH) results.

Authors:  Marco Mueller; Per Poulsen; Rune Hansen; Wilko Verbakel; Ross Berbeco; Dianne Ferguson; Shinichiro Mori; Lei Ren; John C Roeske; Lei Wang; Pengpeng Zhang; Paul Keall
Journal:  Med Phys       Date:  2021-12-29       Impact factor: 4.071

4.  Motion management during IMAT treatment of mobile lung tumors--a comparison of MLC tracking and gated delivery.

Authors:  Marianne Falk; Tobias Pommer; Paul Keall; Stine Korreman; Gitte Persson; Per Poulsen; Per Munck af Rosenschöld
Journal:  Med Phys       Date:  2014-10       Impact factor: 4.071

Review 5.  Image-guided radiotherapy and motion management in lung cancer.

Authors:  S S Korreman
Journal:  Br J Radiol       Date:  2015-05-08       Impact factor: 3.039

Review 6.  Advances in 4D treatment planning for scanned particle beam therapy - report of dedicated workshops.

Authors:  Christoph Bert; Christian Graeff; Marco Riboldi; Simeon Nill; Guido Baroni; Antje-Christin Knopf
Journal:  Technol Cancer Res Treat       Date:  2013-12-17

7.  Audiovisual biofeedback breathing guidance for lung cancer patients receiving radiotherapy: a multi-institutional phase II randomised clinical trial.

Authors:  Sean Pollock; Ricky O'Brien; Kuldeep Makhija; Fiona Hegi-Johnson; Jane Ludbrook; Angela Rezo; Regina Tse; Thomas Eade; Roland Yeghiaian-Alvandi; Val Gebski; Paul J Keall
Journal:  BMC Cancer       Date:  2015-07-18       Impact factor: 4.430

8.  Commissioning of a motion system to investigate dosimetric consequences due to variability of respiratory waveforms.

Authors:  Ashley J Cetnar; Joshua James; Brain Wang
Journal:  J Appl Clin Med Phys       Date:  2016-01-08       Impact factor: 2.102

9.  Does gated beam delivery impact delivery accuracy on an Elekta linac?

Authors:  Mohammed Jermoumi; Roger Xie; Daliang Cao; David J Housley; David M Shepard
Journal:  J Appl Clin Med Phys       Date:  2017-01-03       Impact factor: 2.102

Review 10.  Current Evidence for Stereotactic Body Radiotherapy in Lung Metastases.

Authors:  Enrique Gutiérrez; Irving Sánchez; Omar Díaz; Adrián Valles; Ricardo Balderrama; Jesús Fuentes; Brenda Lara; Cipatli Olimón; Víctor Ruiz; José Rodríguez; Luis H Bayardo; Matthew Chan; Conrad J Villafuerte; Jerusha Padayachee; Alexander Sun
Journal:  Curr Oncol       Date:  2021-07-15       Impact factor: 3.677

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.