Literature DB >> 23523204

Analysis of stem tip pain in revision total knee arthroplasty.

Christine I Kimpton1, Andrew David Crocombe, William Neil Bradley, Brigstocke Gavin Huw Owen.   

Abstract

Stem tip pain following revision total knee arthroplasty is a significant cause of patient dissatisfaction, which in the presence of an aseptic well-fixed component has no widely accepted surgical solution. A definitive cause of stem tip pain remains elusive, however it has been suggested that high stress concentrations within the region of the stem tip may play a role. This paper reports a finite element study of a novel clinical technique where a plate is attached to the tibia within the region of the stem tip to reduce stem tip pain. The results demonstrate that the plate reduces stress concentrations in the bone at the stem tip of the implant. The magnitude of stress reduction is dependent upon plate location, material and attachment method.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23523204     DOI: 10.1016/j.arth.2012.10.007

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  6 in total

Review 1.  Management of bone loss in revision total knee arthroplasty: therapeutic options and results.

Authors:  E Carlos Rodríguez-Merchán; Primitivo Gómez-Cardero; Carlos A Encinas-Ullán
Journal:  EFORT Open Rev       Date:  2021-11-19

2.  Comparing Revision Total Knee Arthroplasty Stems at a High-Volume Revision Center.

Authors:  Bernard P Kemker; Christopher B Sowers; Raees Seedat; Jibanananda Satpathy; Nirav K Patel; Daniel J Lombardo; Gregory J Golladay
Journal:  Front Surg       Date:  2022-03-11

3.  Stress-Induced, Aseptic Osteolysis of the Mid-Tibia in a Revision Hinged Total Knee Arthroplasty Mimicking Infection.

Authors:  Scott Galey; Chad Ishmael; Stephen Zoller; Matthew Dipane; Edward McPherson
Journal:  Arthroplast Today       Date:  2022-03-09

4.  Biomechanical effect of anatomical tibial component design on load distribution of medial proximal tibial bone in total knee arthroplasty : finite element analysis indicating anatomical design prevents stress-shielding.

Authors:  Byung W Cho; Kyoung-Tak Kang; Hyuck M Kwon; Woo-Suk Lee; Ick H Yang; Ji H Nam; Yong-Gon Koh; Kwan K Park
Journal:  Bone Joint Res       Date:  2022-05       Impact factor: 4.410

5.  Tibial metaphyseal cones combined with short stems perform as well as long stems in revision total knee arthroplasty.

Authors:  Bruno Batinica; Scott M Bolam; Matt D'Arcy; Mark Zhu; A Paul Monk; Jacob T Munro
Journal:  ANZ J Surg       Date:  2022-06-27       Impact factor: 2.025

6.  Biomechanical evaluation of tibial bone adaptation after revision total knee arthroplasty: A comparison of different implant systems.

Authors:  María Paz Quilez; Belen Seral; María Angeles Pérez
Journal:  PLoS One       Date:  2017-09-08       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.