Literature DB >> 23523059

Effect of transcatheter (via femoral artery) aortic valve implantation on the platelet count and its consequences.

Romain Gallet1, Aurelien Seemann, Masanori Yamamoto, Delphine Hayat, Gauthier Mouillet, Jean-Luc Monin, Pascal Gueret, Jean-Paul Couetil, Jean-Luc Dubois-Randé, Emmanuel Teiger, Pascal Lim.   

Abstract

Decrease in blood platelet count has been described after percutaneous coronary intervention and surgical valve replacement, although no study has been performed in the setting of transcatheter aortic valve implantation (TAVI). The aim of this study was to address the incidence, mechanism, and impact of blood platelet count decrease after TAVI. One hundred forty-four consecutive patients (mean age 84 ± 7 years, 64 men) with severe symptomatic aortic stenosis who underwent TAVI from December 2007 to July 2011 were enrolled. Blood platelet count was recorded before and after aortic valve implantation. Decrease in blood platelet count was compared with in-hospital major adverse cardiovascular events (death, stroke, and major or life-threatening bleeding). Blood platelet count decreases occurred in all but 1 patient. The percentage of platelet count decrease averaged 34 ± 15% and was 24% greater than blood protein decrease. Decrease in platelet count was associated with a higher rate of prosthesis migration, longer x-ray and procedural times, and larger contrast amounts (230 ± 128 ml for the third tertile vs 170 ± 77 ml for the second and first tertiles, p = 0.0006), but no association was observed with regard to changes in bilirubin. In-hospital major adverse cardiovascular events (n = 50 [35%]) were observed more frequently in patients with severe platelet count decreases (21% for the first tertile, 35% for the second tertile, and 48% for the third tertile, p = 0.02). Finally, the percentage of blood platelet count decrease was the only predictor of in-hospital major adverse cardiovascular events (odds ratio 1.67, 95% confidence interval 1.05 to 2.67, p = 0.03). In conclusion, a decrease in platelet count is a common phenomenon after TAVI, and its severity is associated with poor outcomes.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23523059     DOI: 10.1016/j.amjcard.2013.01.332

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  12 in total

1.  Thromboinflammatory response and predictors of outcomes in patients undergoing transcatheter aortic valve replacement.

Authors:  Travis R Sexton; Eric L Wallace; Amy Chen; Richard J Charnigo; Hassan K Reda; Khaled M Ziada; John C Gurley; Susan S Smyth
Journal:  J Thromb Thrombolysis       Date:  2016-04       Impact factor: 2.300

2.  Realistic Vascular Replicator for TAVR Procedures.

Authors:  Oren M Rotman; Brandon Kovarovic; Chander Sadasivan; Luis Gruberg; Baruch B Lieber; Danny Bluestein
Journal:  Cardiovasc Eng Technol       Date:  2018-04-13       Impact factor: 2.495

3.  Preprocedural P2Y12 inhibition and decrease in platelet count following transcatheter aortic valve replacement.

Authors:  Homam Ibrahim; Eleonora Vapheas; Binita Shah; Ahmad AlKhalil; Michael Querijero; Hasan Jilaihawi; Peter Neuburger; Cezar Staniloae; Mathew R Williams
Journal:  Catheter Cardiovasc Interv       Date:  2019-05-06       Impact factor: 2.692

Review 4.  Quantitative and Qualitative Platelet Derangements in Cardiac Surgery and Extracorporeal Life Support.

Authors:  Enrico Squiccimarro; Federica Jiritano; Giuseppe Filiberto Serraino; Hugo Ten Cate; Domenico Paparella; Roberto Lorusso
Journal:  J Clin Med       Date:  2021-02-06       Impact factor: 4.241

5.  Association between time-related changes in routine blood morphological parameters and renal function after transcatheter aortic valve implantation - a preliminary study.

Authors:  Konrad Stelmark; Eli Adrian Zaher; Anna Olasińska-Wiśniewska; Michael Adesina; Alicia Dragone; Martha Isaac; Marcin Misterski; Marek Grygier; Mateusz Puślecki; Maciej Lesiak; Marek Jemielity; Bartłomiej Perek
Journal:  Kardiochir Torakochirurgia Pol       Date:  2021-10-05

6.  Can Blood Biomarkers Help Predicting Outcome in Transcatheter Aortic Valve Implantation?

Authors:  Cécile Oury; Alain Nchimi; Patrizio Lancellotti; Jutta Bergler-Klein
Journal:  Front Cardiovasc Med       Date:  2018-03-28

7.  Thrombocytopenia After Aortic Valve Replacement: Comparison Between Sutureless Perceval S Valve and Perimount Magna Ease Bioprosthesis.

Authors:  Syed Saleem Mujtaba; Simon Ledingham; Asif Raza Shah; Stephan Schueler; Stephen Clark; Thasee Pillay
Journal:  Braz J Cardiovasc Surg       Date:  2018 Mar-Apr

8.  Risk of reduced platelet counts in patients with nonalcoholic fatty liver disease (NAFLD): a prospective cohort study.

Authors:  Fang Liu; Hui Zhou; Lei Cao; Zhirong Guo; Chen Dong; Lugang Yu; Yiying Wang; Chunxing Liu; Jing Qiu; Yong Xue; Xingxiang Liu; Yunfang Xu
Journal:  Lipids Health Dis       Date:  2018-09-19       Impact factor: 3.876

9.  Peri-procedural hemostasis disorders in surgical and transcatheter aortic valve implantation.

Authors:  Katarzyna Czerwińska-Jelonkiewicz; Krzysztof Milewski; Piotr Buszman; Przemysław Kwasiborski; Krzysztof Sanetra; Wojciech Domaradzki; Paweł Buszman
Journal:  Postepy Kardiol Interwencyjnej       Date:  2019-03-15       Impact factor: 1.426

10.  Predictors of short-term thrombocytopenia after transcatheter aortic valve implantation: a retrospective study at a single Japanese center.

Authors:  Yasutaka Yamada; Daisuke Miura; Ayako Takamori; Eijiro Nogami; Junji Yunoki; Yoshiro Sakaguchi
Journal:  BMC Res Notes       Date:  2020-11-16
View more