Literature DB >> 23522603

Intraoperative combined color and fluorescent images-based sentinel node mapping in the porcine lung: comparison of indocyanine green with or without albumin premixing.

Yujin Oh1, Yu Hua Quan, Yeonho Choi, Choong Ki Kim, Heezoo Kim, Hyun Koo Kim, Beop-Min Kim.   

Abstract

OBJECTIVES: We developed a multimodal optical imaging system for intraoperative visualization of sentinel lymph nodes (SLNs). This study is to validate our system by showing SLNs in the lung through combined optical color and fluorescent image with indocyanine green (ICG) and ICG with human serum albumin (HSA).
METHODS: Identical ICG concentrations of ICG only or ICG:HSA was injected into the rat footpad and porcine lung. Absolute amounts of the fluorescents were scaled on the basis of animal weights. The entire procedures were recorded using color and near-infrared (NIR) charge-coupled device (CCD) cameras simultaneously, and the 2 images were merged by real-time image processing software. All fluorescence intensity signals to background ratio (SBR) and retention rates at SLN for both fluorescents were estimated and compared.
RESULTS: This newly developed intraoperative color and fluorescence optical imaging system successfully visualized the SLNs in animal experiments. The SLNs were identified 100% for both rat and pig under in vivo conditions. Real-time image processing software overcame the low signal of NIR fluorescence images. ICG and ICG:HSA provided no significantly different SBR in the SLN images for both rat thigh and pig lung.
CONCLUSIONS: The intraoperative optical imaging system enabled real-time image-guided surgery during SLN mapping in lung in an animal model. The ICG retention rate was similar to ICG:HSA. ICG alone can be useful for SLN imaging during lung cancer surgery.
Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

Entities:  

Keywords:  10.4; 9; CCD; HSA; ICFIS; ICG; NIR; SBR; SLN; charge-coupled device; human serum albumin; indocyanine green; intraoperative color and fluorescence imaging system; near-infrared; sentinel lymph node; signal to background ratio

Mesh:

Substances:

Year:  2013        PMID: 23522603     DOI: 10.1016/j.jtcvs.2013.02.044

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  11 in total

1.  Utility and pitfalls of sentinel node identification using indocyanine green during segmentectomy for cT1N0M0 non-small cell lung cancer.

Authors:  Hiroaki Nomori; Yue Cong; Hiroshi Sugimura
Journal:  Surg Today       Date:  2015-09-08       Impact factor: 2.549

Review 2.  Current innovations in sentinel lymph node mapping for the staging and treatment of resectable lung cancer.

Authors:  Krista J Hachey; Yolonda L Colson
Journal:  Semin Thorac Cardiovasc Surg       Date:  2014-09-16

3.  Fluorescence Imaging-Guided Identification of Thymic Masses Using Low-Dose Indocyanine Green.

Authors:  Yu Hua Quan; Rong Xu; Byeong Hyeon Choi; Jiyun Rho; Jun Hee Lee; Kook Nam Han; Young Ho Choi; Beop-Min Kim; Hyun Koo Kim
Journal:  Ann Surg Oncol       Date:  2022-03-09       Impact factor: 5.344

4.  Fluorescent image-based evaluation of gastric conduit perfusion in a preclinical ischemia model.

Authors:  Yu Hua Quan; Minji Kim; Hyun Koo Kim; Beop-Min Kim
Journal:  J Thorac Dis       Date:  2018-09       Impact factor: 2.895

5.  Minimally invasive electro-magnetic navigational bronchoscopy-integrated near-infrared-guided sentinel lymph node mapping in the porcine lung.

Authors:  Hironobu Wada; Kentaro Hirohashi; Takashi Anayama; Takahiro Nakajima; Tatsuya Kato; Harley H L Chan; Jimmy Qiu; Michael Daly; Robert Weersink; David A Jaffray; Jonathan C Irish; Thomas K Waddell; Shaf Keshavjee; Ichiro Yoshino; Kazuhiro Yasufuku
Journal:  PLoS One       Date:  2015-05-20       Impact factor: 3.240

6.  Mid-Infrared Imaging Is Able to Characterize and Separate Cancer Cell Lines.

Authors:  E Kontsek; A Pesti; M Björnstedt; T Üveges; E Szabó; T Garay; P Gordon; S Gergely; A Kiss
Journal:  Pathol Oncol Res       Date:  2020-06-16       Impact factor: 3.201

7.  Human Serum Albumin Decorated Indocyanine Green Improves Fluorescence-Guided Resection of Residual Lesions of Breast Cancer in Mice.

Authors:  Zun Wang; Min Chen; Jing-Jing Liu; Rong-He Chen; Qian Yu; Gui-Mei Wang; Li-Ming Nie; Wen-He Huang; Guo-Jun Zhang
Journal:  Front Oncol       Date:  2021-03-08       Impact factor: 6.244

8.  Near-infrared fluorescent imaging with indocyanine green in rabbit and patient specimens of esophageal cancer.

Authors:  Jiyun Rho; Yu Hua Quan; Byeong Hyeon Choi; Kook Nam Han; Beop-Min Kim; Young Ho Choi; Hyun Koo Kim
Journal:  J Thorac Dis       Date:  2021-11       Impact factor: 2.895

9.  Design and Testing of Augmented Reality-Based Fluorescence Imaging Goggle for Intraoperative Imaging-Guided Surgery.

Authors:  Seung Hyun Lee; Yu Hua Quan; Min Sub Kim; Ki Hyeok Kwon; Byeong Hyeon Choi; Hyun Koo Kim; Beop-Min Kim
Journal:  Diagnostics (Basel)       Date:  2021-05-21

10.  Fluorescence Imaging Topography Scanning System for intraoperative multimodal imaging.

Authors:  Tri T Quang; Hye-Yeong Kim; Forrest Sheng Bao; Francis A Papay; W Barry Edwards; Yang Liu
Journal:  PLoS One       Date:  2017-04-24       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.