Literature DB >> 23521942

To pump or not to pump: a comparison of machine perfusion vs cold storage for deceased donor kidney transplantation.

Robert M Cannon1, Guy N Brock, R Neal Garrison, Jason W Smith, Michael R Marvin, Glen A Franklin.   

Abstract

BACKGROUND: A recent multicenter European trial has demonstrated reduced rates of delayed graft function when kidneys undergo machine perfusion before transplantation. This study was undertaken to evaluate the impact of machine perfusion on early kidney transplant function in the United States. STUDY
DESIGN: Retrospective review of United Network for Organ Sharing data from January 1, 2005 through March 31, 2011 was undertaken. Comparisons were made between kidneys that underwent machine perfusion (MP) vs cold storage (CS) alone in terms of delayed graft function (DGF). The analysis was performed in a cohort of MP and CS kidneys matched by propensity scoring, as well as in a cohort of paired kidneys from the same donor in which one underwent MP and the other underwent CS. Secondary end points analyzed included recipient length of stay after transplantation and graft survival.
RESULTS: In the overall cohort, rates of DGF were similar for MP and CS kidneys (25.7% vs 25.0%; p = 0.082), likely due to preferential use of MP in marginal kidneys. In the propensity matched cohort, MP was associated with significantly lower rates of DGF compared with CS (21.1% vs 29.1%; p < 0.001). These findings were corroborated by the paired kidney analysis, in which DGF occurred in 19.7% of the MP group compared with 27.5% of the CS group (p < 0.001). There was no difference in the hazard for graft failure between the MP and CS group in the propensity matched analysis (hazard ratio = 0.98; p = 0.622) and in the paired kidney analysis (hazard ratio = 1.02; p = 0.839).
CONCLUSIONS: Machine perfusion of deceased donor kidneys results in significantly decreased rates of DGF. Published by Elsevier Inc.

Entities:  

Mesh:

Year:  2013        PMID: 23521942     DOI: 10.1016/j.jamcollsurg.2012.12.025

Source DB:  PubMed          Journal:  J Am Coll Surg        ISSN: 1072-7515            Impact factor:   6.113


  12 in total

Review 1.  German recommendations for pretransplantation donor kidney biopsies.

Authors:  Przemyslav Pisarski; Christina Schleicher; Ingeborg Hauser; Jan U Becker
Journal:  Langenbecks Arch Surg       Date:  2016-03-19       Impact factor: 3.445

2.  Associations of Perfusate Biomarkers and Pump Parameters With Delayed Graft Function and Deceased Donor Kidney Allograft Function.

Authors:  C R Parikh; I E Hall; R S Bhangoo; J Ficek; P L Abt; H Thiessen-Philbrook; H Lin; M Bimali; P T Murray; V Rao; B Schröppel; M D Doshi; F L Weng; P P Reese
Journal:  Am J Transplant       Date:  2016-02-17       Impact factor: 8.086

3.  Factors predicting kidney delayed graft function among recipients of simultaneous liver-kidney transplantation: A single-center experience.

Authors:  Islam M Korayem; Vatche G Agopian; Keri E Lunsford; Hans A Gritsch; Jeffrey L Veale; Gerald S Lipshutz; Hasan Yersiz; Coney L Serrone; Fady M Kaldas; Douglas G Farmer; Suphamai Bunnapradist; Gabriel M Danovitch; Ronald W Busuttil; Ali Zarrinpar
Journal:  Clin Transplant       Date:  2019-05-07       Impact factor: 2.863

4.  Machine perfusion and long-term kidney transplant recipient outcomes across allograft risk strata.

Authors:  Shaifali Sandal; Xun Luo; Allan B Massie; Steven Paraskevas; Marcelo Cantarovich; Dorry L Segev
Journal:  Nephrol Dial Transplant       Date:  2018-07-01       Impact factor: 5.992

5.  Metabolomic perfusate analysis during kidney machine perfusion: the pig provides an appropriate model for human studies.

Authors:  Jay Nath; Alison Guy; Thomas B Smith; Mark Cobbold; Nicholas G Inston; James Hodson; Daniel A Tennant; Christian Ludwig; Andrew R Ready
Journal:  PLoS One       Date:  2014-12-12       Impact factor: 3.240

6.  Protection of the Transplant Kidney from Preservation Injury by Inhibition of Matrix Metalloproteinases.

Authors:  Michael A J Moser; Steve Arcand; Han-Bin Lin; Chris Wojnarowicz; Jolanta Sawicka; Tamalina Banerjee; Yigang Luo; Gavin R Beck; Patrick P Luke; Grzegorz Sawicki
Journal:  PLoS One       Date:  2016-06-21       Impact factor: 3.240

Review 7.  Maximizing kidneys for transplantation using machine perfusion: from the past to the future: A comprehensive systematic review and meta-analysis.

Authors:  Ahmer M Hameed; Henry C Pleass; Germaine Wong; Wayne J Hawthorne
Journal:  Medicine (Baltimore)       Date:  2016-10       Impact factor: 1.889

8.  Proteomic Analysis of Perfusate from Machine Cold Perfusion of Transplant Kidneys: Insights Into Protection from Injury.

Authors:  Michael A J Moser; Katherine Sawicka; Steven Arcand; Preston O'Brien; Patrick Luke; Gavin Beck; Jolanta Sawicka; Alejandro Cohen; Grzegorz Sawicki
Journal:  Ann Transplant       Date:  2017-12-08       Impact factor: 1.530

Review 9.  Machine Perfusion of Extended Criteria Donor Organs: Immunological Aspects.

Authors:  Mindaugas Kvietkauskas; Bettina Leber; Kestutis Strupas; Philipp Stiegler; Peter Schemmer
Journal:  Front Immunol       Date:  2020-02-27       Impact factor: 7.561

10.  Personalized prediction of delayed graft function for recipients of deceased donor kidney transplants with machine learning.

Authors:  Satoru Kawakita; Jennifer L Beaumont; Vadim Jucaud; Matthew J Everly
Journal:  Sci Rep       Date:  2020-10-27       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.