Literature DB >> 23521468

Covered transjugular intrahepatic portosystemic shunts: accuracy of ultrasound in detecting shunt malfunction.

Bjorn I Engstrom1, Jeffrey J Horvath, Paul V Suhocki, Alastair D Smith, Barbara S Hertzberg, Tony P Smith, Charles Y Kim.   

Abstract

OBJECTIVE: The purpose of this study was to determine the accuracy of ultrasound for detecting transjugular intrahepatic portosystemic shunt (TIPS) malfunction in covered stents in comparison with bare metal stents.
MATERIALS AND METHODS: During a 6-year period, 126 TIPS angiography examinations were performed in 78 patients who had undergone a recent TIPS ultrasound examination. Radiology reports and images were retrospectively reviewed, and the sensitivity and specificity of sonographic parameters for detecting TIPS dysfunction were calculated using TIPS angiography and portosystemic gradient as the reference standards.
RESULTS: Of 126 paired studies, 43 were in bare metal TIPS and 83 were in covered TIPS. Peak shunt velocity of covered and bare metal TIPS measured by ultrasound showed comparable sensitivities for detection of shunt dysfunction, using both depressed (< 90 cm/s) and elevated (> 200 cm/s) peak shunt velocity criteria. However, a depressed velocity was more specific in covered TIPS (0.939 vs 0.550, p < 0.001) whereas elevated velocity was more specific in bare TIPS (0.485 vs 0.800, p = 0.041). An interval change in peak TIPS velocity greater than 25% was significantly more sensitive in detection of dysfunction in covered TIPS (0.815 vs 0.400, p = 0.015) whereas detection based on main portal vein velocities (≤ 30 cm/s) was not statistically different in the two groups.
CONCLUSION: Our data suggest that the accuracy of ultrasound for detection of TIPS shunt malfunction is at least as high in covered stents as in bare metal stents. Diagnostic performance for several sonographic parameters varied significantly between bare and covered stents, suggesting the need for optimization of sonographic criteria for covered stents.

Entities:  

Mesh:

Year:  2013        PMID: 23521468     DOI: 10.2214/AJR.12.8761

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  7 in total

Review 1.  An Algorithm for Management After Transjugular Intrahepatic Portosystemic Shunt Placement According to Clinical Manifestations.

Authors:  Seung Kwon Kim; Bryan G Belikoff; Carlos J Guevara; Seong Jin Park
Journal:  Dig Dis Sci       Date:  2017-01-05       Impact factor: 3.199

2.  Use of doppler ultrasound to predict need for transjugular intrahepatic portosystemic shunt revision.

Authors:  Nikki Duong; Marcus Healey; Kunal Patel; Brian J Strife; Richard K Sterling
Journal:  World J Hepatol       Date:  2022-06-27

3.  Pathological Predictors of Shunt Stenosis and Hepatic Encephalopathy after Transjugular Intrahepatic Portosystemic Shunt.

Authors:  Fuliang He; Shan Dai; Zhibo Xiao; Lei Wang; Zhendong Yue; Hongwei Zhao; Mengfei Zhao; Qiushi Lin; Xiaoqun Dong; Fuquan Liu
Journal:  Biomed Res Int       Date:  2016-11-15       Impact factor: 3.411

4.  Transjugular Intrahepatic Portosystemic Shunt Dysfunction: Concordance of Clinical Findings, Doppler Ultrasound Examination, and Shunt Venography.

Authors:  Joshua M Owen; Ron Charles Gaba
Journal:  J Clin Imaging Sci       Date:  2016-07-18

5.  The Pull-Through Technique for Recanalization of Transjugular Intrahepatic Portosystemic Shunt Dysfunction.

Authors:  Si-Liang Chen; Cheng-Jiang Xiao; Shuai Wang; Si-Yi Jin; Jian-Bo Zhao
Journal:  Gastroenterol Res Pract       Date:  2020-04-27       Impact factor: 2.260

Review 6.  Transjugular intrahepatic portosystemic shunt in cirrhosis: An exhaustive critical update.

Authors:  Sasidharan Rajesh; Tom George; Cyriac Abby Philips; Rizwan Ahamed; Sandeep Kumbar; Narain Mohan; Meera Mohanan; Philip Augustine
Journal:  World J Gastroenterol       Date:  2020-10-07       Impact factor: 5.742

Review 7.  North American Practice-Based Recommendations for Transjugular Intrahepatic Portosystemic Shunts in Portal Hypertension.

Authors:  Justin R Boike; Bartley G Thornburg; Sumeet K Asrani; Michael B Fallon; Brett E Fortune; Manhal J Izzy; Elizabeth C Verna; Juan G Abraldes; Andrew S Allegretti; Jasmohan S Bajaj; Scott W Biggins; Michael D Darcy; Maryjane A Farr; Khashayar Farsad; Guadalupe Garcia-Tsao; Shelley A Hall; Caroline C Jadlowiec; Michael J Krowka; Jeanne Laberge; Edward W Lee; David C Mulligan; Mitra K Nadim; Patrick G Northup; Riad Salem; Joseph J Shatzel; Cathryn J Shaw; Douglas A Simonetto; Jonathan Susman; K Pallav Kolli; Lisa B VanWagner
Journal:  Clin Gastroenterol Hepatol       Date:  2021-07-15       Impact factor: 13.576

  7 in total