Literature DB >> 23520394

Comparison of precision and accuracy of linear measurements performed by two different imaging software programs and obtained from 3D-CBCT images for Le Fort I osteotomy.

B F Gaia1, L R Pinheiro, O S Umetsubo, F F Costa, M G P Cavalcanti.   

Abstract

OBJECTIVE: The purpose of this study was to compare the precision and accuracy of linear measurements for Le Fort I osteotomy performed by two different imaging software programs and obtained from three-dimensional cone beam CT (3D-CBCT) images.
METHODS: The study population consisted of 11 dried skulls submitted to CBCT, which generated 3D images. Linear measurements were based on craniometric anatomical landmarks pre-defined by the authors as specifically used for Le Fort I osteotomy and were identified by two radiologists twice each, independently, using Vitrea 3.8.1 (Vital Images Inc., Plymouth, MN) and open-source digital imaging communication in medicine viewer OsiriX 1.2 64-bit (Pixmeo, Geneva, Switzerland). Subsequently, a third examiner made physical measurements using a digital caliper (167 series; Mitutoyo Sul Americana Ltd, Suzano, SP, Brazil).
RESULTS: The results demonstrated a statistically significant difference between OsiriX and the gold standard, especially in the pterygoid process (TPtg L = 0.019, LLpPtg R = 0.016 and LLpPtg L = 0.012). Vitrea showed no statistical difference in comparison with the gold standard, and showed a high level of accuracy in all the measurements performed. The major difference found was 0.42 mm (LLpPtg R). Interexaminer analysis ranged from 0.90 to 0.97 using Vitrea and from 0.8 to 0.97 using OsiriX. Intraexaminer correlation coefficient ranged from 0.90 to 0.98 and from 0.84 to 0.98 for Examiners 1 and 2, respectively, using Vitrea and from 0.93 to 0.99 for Examiner 1 and from 0.64 to 0.96 for Examiner 2 using OsiriX.
CONCLUSION: Vitrea may be considered as precise and accurate, insofar as it was able to perform all the 3D linear measurements. On the other hand, linear measurements performed using OsiriX were not successful in producing accurate linear measurements for Le Fort I osteotomy.

Entities:  

Mesh:

Year:  2013        PMID: 23520394      PMCID: PMC3635772          DOI: 10.1259/dmfr.20120178

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  26 in total

1.  3-D volume imaging for dentistry: a new dimension.

Authors:  Robert A Danforth; Ivan Dus; James Mah
Journal:  J Calif Dent Assoc       Date:  2003-11

2.  Three-dimensional surface imaging: limitations and considerations from the anthropometric perspective.

Authors:  Seth M Weinberg; John C Kolar
Journal:  J Craniofac Surg       Date:  2005-09       Impact factor: 1.046

3.  Three-dimensional cone beam computerized tomography in orthodontics.

Authors:  C H Kau; S Richmond; J M Palomo; M G Hans
Journal:  J Orthod       Date:  2005-12

4.  Image analysis and superimposition of 3-dimensional cone-beam computed tomography models.

Authors:  Lucia H S Cevidanes; Martin A Styner; William R Proffit
Journal:  Am J Orthod Dentofacial Orthop       Date:  2006-05       Impact factor: 2.650

5.  Using a clinical protocol for orthognathic surgery and assessing a 3-dimensional virtual approach: current therapy.

Authors:  Luis A Quevedo; Jessica V Ruiz; Cristobal A Quevedo
Journal:  J Oral Maxillofac Surg       Date:  2011-03       Impact factor: 1.895

6.  Three-dimensional computed tomography landmark measurement in craniofacial surgical planning: experimental validation in vitro.

Authors:  M G Cavalcanti; J W Haller; M W Vannier
Journal:  J Oral Maxillofac Surg       Date:  1999-06       Impact factor: 1.895

7.  Validity of multislice computerized tomography for diagnosis of maxillofacial fractures using an independent workstation.

Authors:  Denise Takehana Dos Santos; Adriana Paula Andrade Costa e Silva; Michael Walter Vannier; Marcelo Gusmão Paraiso Cavalcanti
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2004-12

8.  A proposal for a new analysis of craniofacial morphology by 3-dimensional computed tomography.

Authors:  Sun-Hyung Park; Hyung-Seog Yu; Kee-Deog Kim; Kee-Joon Lee; Hyoung-Seon Baik
Journal:  Am J Orthod Dentofacial Orthop       Date:  2006-05       Impact factor: 2.650

9.  Early orthognathic surgery with three-dimensional image simulation during presurgical orthodontics in adults.

Authors:  Sang-Hoon Kang; Moon-Key Kim; Sun-Yeon Park; Ji-Yeon Lee; Wonse Park; Sang-Hwy Lee
Journal:  J Craniofac Surg       Date:  2011-03       Impact factor: 1.046

10.  Intra- and perioperative complications of the LeFort I osteotomy: a prospective evaluation of 1000 patients.

Authors:  Franz-Josef Kramer; Carola Baethge; Gwen Swennen; Thomas Teltzrow; Andrea Schulze; Johannes Berten; Peter Brachvogel
Journal:  J Craniofac Surg       Date:  2004-11       Impact factor: 1.046

View more
  3 in total

1.  Comparison of ABC/2 estimation and a volumetric computerized method for measurement of meningiomas using magnetic resonance imaging.

Authors:  Charles F Opalak; Matthew Parry; Andrew K Rock; Adam P Sima; Matthew T Carr; Vyshak Chandra; Kathryn G Workman; Aravind Somasundaram; William C Broaddus
Journal:  J Neurooncol       Date:  2019-08-10       Impact factor: 4.130

2.  Impact of Digital Panoramic Radiograph Magnification on Vertical Measurement Accuracy.

Authors:  Marc El Hage; Jean-Pierre Bernard; Christophe Combescure; Lydia Vazquez
Journal:  Int J Dent       Date:  2015-10-19

3.  Influence of image-viewers and artifacts on implant length measurements in cone-beam computed tomography: an in vitro study.

Authors:  Lydia Vazquez; Murali Srinivasan; Firas Khouja; Christophe Combescure; Jean-Pierre Carrel
Journal:  Clin Exp Dent Res       Date:  2016-02-10
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.