Literature DB >> 23517775

Eliminating adhesion errors in nanoindentation of compliant polymers and hydrogels.

Julie C Kohn1, Donna M Ebenstein.   

Abstract

Nanoindentation is a valuable tool for characterization of biomaterials due to its ability to measure local properties in heterogeneous, small or irregularly shaped samples. However, applying nanoindentation to compliant, hydrated biomaterials leads to many challenges including adhesion between the nanoindenter tip and the sample. Although adhesion leads to overestimation of the modulus of compliant samples when analyzing nanoindentation data using traditional analysis techniques, most studies of biomaterials have ignored its effects. This paper demonstrates two methods for managing adhesion in nanoindentation analysis, the nano-JKR force curve method and the surfactant method, through application to two biomedically-relevant compliant materials, poly(dimethyl siloxane) (PDMS) elastomers and poly(ethylene glycol) (PEG) hydrogels. The nano-JKR force curve method accounts for adhesion during data analysis using equations based on the Johnson-Kendall-Roberts (JKR) adhesion model, while the surfactant method eliminates adhesion during data collection, allowing data analysis using traditional techniques. In this study, indents performed in air or water resulted in adhesion between the tip and the sample, while testing the same materials submerged in Optifree Express(®) contact lens solution eliminated tip-sample adhesion in most samples. Modulus values from the two methods were within 7% of each other, despite different hydration conditions and evidence of adhesion. Using surfactant also did not significantly alter the properties of the tested material, allowed accurate modulus measurements using commercial software, and facilitated nanoindentation testing in fluids. This technique shows promise for more accurate and faster determination of modulus values from nanoindentation of compliant, hydrated biological samples.
Copyright © 2013 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23517775     DOI: 10.1016/j.jmbbm.2013.02.002

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  11 in total

Review 1.  Measuring the elastic modulus of soft culture surfaces and three-dimensional hydrogels using atomic force microscopy.

Authors:  Michael D A Norman; Silvia A Ferreira; Geraldine M Jowett; Laurent Bozec; Eileen Gentleman
Journal:  Nat Protoc       Date:  2021-04-14       Impact factor: 13.491

2.  Mechanical properties of gray and white matter brain tissue by indentation.

Authors:  Silvia Budday; Richard Nay; Rijk de Rooij; Paul Steinmann; Thomas Wyrobek; Timothy C Ovaert; Ellen Kuhl
Journal:  J Mech Behav Biomed Mater       Date:  2015-03-02

3.  Effects of material thickness and processing method on poly(lactic-co-glycolic acid) degradation and mechanical performance.

Authors:  Reyhaneh Neghabat Shirazi; Fawaz Aldabbagh; William Ronan; Andrea Erxleben; Yury Rochev; Peter McHugh
Journal:  J Mater Sci Mater Med       Date:  2016-09-02       Impact factor: 3.896

4.  Multi-modal magnetic resonance elastography for noninvasive assessment of ovarian tissue rigidity in vivo.

Authors:  Charles D Wood; Mayank Vijayvergia; Frank H Miller; Timothy Carroll; Charles Fasanati; Lonnie D Shea; L Catherine Brinson; Teresa K Woodruff
Journal:  Acta Biomater       Date:  2014-11-20       Impact factor: 8.947

5.  Microscale Photopatterning of Through-thickness Modulus in a Monolithic and Functionally Graded 3D Printed Part.

Authors:  Asais Camila Uzcategui; Callie I Higgins; John E Hergert; Andrew E Tomaschke; Victor Crespo-Cuevas; Virginia L Ferguson; Stephanie J Bryant; Robert R McLeod; Jason P Killgore
Journal:  Small Sci       Date:  2020-12-24

6.  Microindentation of cartilage before and after articular loading in a bioreactor: assessment of length-scale dependency using two analysis methods.

Authors:  C Yuh; C S O'Bryan; T E Angelini; M A Wimmer
Journal:  Exp Mech       Date:  2021-06-23       Impact factor: 2.794

Review 7.  Age-related vascular stiffening: causes and consequences.

Authors:  Julie C Kohn; Marsha C Lampi; Cynthia A Reinhart-King
Journal:  Front Genet       Date:  2015-03-30       Impact factor: 4.599

8.  Alginate-Collagen Fibril Composite Hydrogel.

Authors:  Mahmoud Baniasadi; Majid Minary-Jolandan
Journal:  Materials (Basel)       Date:  2015-02-16       Impact factor: 3.623

9.  Theoretical Considerations and a Mathematical Model for the Analysis of the Biomechanical Response of Human Keratinized Oral Mucosa.

Authors:  Aikaterini Tsaira; Panagiotis Karagiannidis; Margarita Sidira; Spyros Kassavetis; Dimitris Kugiumtzis; Stergios Logothetidis; Olga Naka; Argirios Pissiotis; Konstantinos Michalakis
Journal:  Front Physiol       Date:  2016-08-29       Impact factor: 4.566

Review 10.  Depth-Sensing Indentation as a Micro- and Nanomechanical Approach to Characterisation of Mechanical Properties of Soft, Biological, and Biomimetic Materials.

Authors:  Nikolay V Perepelkin; Feodor M Borodich; Alexander E Kovalev; Stanislav N Gorb
Journal:  Nanomaterials (Basel)       Date:  2019-12-19       Impact factor: 5.076

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.