Literature DB >> 23515150

Diagnosis of simulated external root resorption using conventional intraoral film radiography, CCD, PSP, and CBCT: a comparison study.

Abbas Shokri1, Hamed Mortazavi, Fatemeh Salemi, Adineh Javadian, Hamidreza Bakhtiari, Hooman Matlabi.   

Abstract

BACKGROUND: Diagnosis of external root resorption (ERR) cavities may be challenging, especially when no clinical signs are seen. Therefore, the aim of this study was to compare the efficacy of conventional intraoral film radiography, charge-coupled device (CCD) detector, photostimulable phosphor plate (PSP) detector, and cone beam computed tomography (CBCT) for the detection of ERR.
METHODS: The study sample comprised 54 maxillary first premolars. Cavities were created by using a low-speed handpiece with round diamond burs of 1 mm in diameter. Digital and conventional radiographs were taken from each tooth. Three observers examined all images for the presence of resorption cavities. Data were statistically analyzed with the χ(2) test. The reliability and degrees of agreement were also determined by the mean of Cohen's Kappa analysis.
RESULTS: The differences between the imaging methods in correct detection of root resorption for all sizes were not significant. For locations of root resorption, significant differences were found between CBCT and other methods in the apical regions.
CONCLUSIONS: CBCT was only useful for detection of cavities located in the apical one-third of the root, compared to other digital or conventional methods.

Entities:  

Mesh:

Year:  2013        PMID: 23515150     DOI: 10.4103/2319-4170.107156

Source DB:  PubMed          Journal:  Biomed J        ISSN: 2319-4170            Impact factor:   4.910


  10 in total

1.  How standard deviation contributes to the validity of a LDF signal: a cohort study of 8 years of dental trauma.

Authors:  Herman J J Roeykens; Peter De Coster; Wolfgang Jacquet; Roeland J G De Moor
Journal:  Lasers Med Sci       Date:  2019-05-16       Impact factor: 3.161

2.  Accuracy of High- and Low-Resolution Cone-Beam Computed Tomographic Scans in the Detection of Impacted Tooth-Induced External Root Resorption: An Ex-Vivo Study.

Authors:  Arash Dabbaghi; Sanaz Sharifi; Masoud Esmaeili
Journal:  Front Dent       Date:  2019-12-20

3.  Influence of Cone-Beam Computed Tomography Voxel Sizes in the Detection of Chemically Induced External Root Resorptions.

Authors:  Mehmet Eray Kolsuz; Hakan Eren; Berkan Çelikten; Perihan Dalgali Evli; Hüsniye Demirtürk Kocasaraç; Kaan Orhan
Journal:  Med Sci Monit       Date:  2022-06-27

4.  Comparison of in vivo 3D cone-beam computed tomography tooth volume measurement protocols.

Authors:  Darren Forst; Simrit Nijjar; Carlos Flores-Mir; Jason Carey; Marc Secanell; Manuel Lagravere
Journal:  Prog Orthod       Date:  2014-12-23       Impact factor: 2.750

5.  Accuracy of conventional and digital radiography in detecting external root resorption.

Authors:  Abbas Mesgarani; Sina Haghanifar; Maryam Ehsani; Samereh Dokhte Yaghub; Ali Bijani
Journal:  Iran Endod J       Date:  2014-10-07

6.  Effects of five levels of noise reduction applied to indirect digital radiography on diagnostic accuracy of external apical root resorption.

Authors:  Sanaz Sharifi Shoshtari; Seyed Arman Mohagheghi; Nastaran Farhadi; Negin Kheradmand; Lida Naderi
Journal:  Dent Res J (Isfahan)       Date:  2020-03-17

7.  Diagnostic Accuracy of Three Cone Beam Computed Tomography Systems and Periapical Radiography for Detection of Fenestration Around Dental Implants.

Authors:  Amir Eskandarloo; Samira Saati; Mahbubeh Purabdolahi Ardakani; Mohamadreza Jamalpour; Naser Mohammad Gholi Mezerji; Vahid Akheshteh
Journal:  Contemp Clin Dent       Date:  2018 Jul-Sep

8.  Effect of Field Of View on Detection of External Root Resorption in Cone-Beam Computed Tomography.

Authors: 
Journal:  Iran Endod J       Date:  2017

9.  Prevalence of Pneumatized Articular Tubercle Using Panoramic Radiography and Cone Beam-Computed Tomography: A Retrospective Study.

Authors:  Supriya Girish Bhalchim; Shraddha C Jugade; Easwaran Ramaswami; Ajas A Gogri; Sonali G Kadam; Hemant R Umarji
Journal:  Contemp Clin Dent       Date:  2018-09

10.  Effect of field-of-view size on gray values derived from cone-beam computed tomography compared with the Hounsfield unit values from multidetector computed tomography scans.

Authors:  Abbas Shokri; Leila Ramezani; Mohsen Bidgoli; Mahdi Akbarzadeh; Karim Ghazikhanlu-Sani; Hamed Fallahi-Sichani
Journal:  Imaging Sci Dent       Date:  2018-03-19