Literature DB >> 23513982

Postfusion pullout strength comparison of a novel pedicle screw with classical pedicle screws on synthetic foams.

Arslan K Arslan1, Teyfik Demir, Mehmet F Ormeci, Necip Camuşcu, Kudret Türeyen.   

Abstract

Pullout is a very common failure mode on the use of pedicle screws. Numerous studies were completed to increase the pullout strength of pedicle screws especially for osteoporotic bones. In this study, a previously designed pedicle screw type was tested before and after fusion condition. Synthetic polyurethane foams were used in all tests. Three different grades of foams were used in tests to simulate severely osteoporotic, osteoporotic, and healthy bones. Test blocks were produced and characterized in our clinical biomechanics laboratory. Foaming of polyurethane was accepted as fusion process (bone in growth). Pedicle screw including radial holes (new design) was tested both before and after the fusion. It also exhibited remarkably higher pullout strength after fusion than before fusion and most of other alternatives stated in the literature. In total, 70% higher pullout strength was achieved with new design after fusion. On the other hand, new design did not dominate other alternatives when comparison was carried out on severely osteoporotic and healthy bones. To the knowledge of the authors, this is the first study investigating the postfusion properties on synthetic foams.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23513982     DOI: 10.1177/0954411912463323

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  4 in total

1.  Suture anchor fixation strength with or without augmentation in osteopenic and severely osteoporotic bones in rotator cuff repair: a biomechanical study on polyurethane foam model.

Authors:  Mehmet Serhan Er; Levent Altinel; Mehmet Eroglu; Ozgur Verim; Teyfik Demir; Halil Atmaca
Journal:  J Orthop Surg Res       Date:  2014-08-22       Impact factor: 2.359

2.  Evaluation of the Effect of Fixation Angle between Polyaxial Pedicle Screw Head and Rod on the Failure of Screw-Rod Connection.

Authors:  Engin Çetin; Mustafa Özkaya; Ümit Özgür Güler; Emre Acaroğlu; Teyfik Demir
Journal:  Appl Bionics Biomech       Date:  2015-02-22       Impact factor: 1.781

3.  Testing Pullout Strength of Pedicle Screw Using Synthetic Bone Models: Is a Bilayer Foam Model a Better Representation of Vertebra?

Authors:  Vicky Varghese; Venkatesh Krishnan; Gurunathan Saravana Kumar
Journal:  Asian Spine J       Date:  2018-06-04

Review 4.  Recent Trends, Technical Concepts and Components of Computer-Assisted Orthopedic Surgery Systems: A Comprehensive Review.

Authors:  Jan Kubicek; Filip Tomanec; Martin Cerny; Dominik Vilimek; Martina Kalova; David Oczka
Journal:  Sensors (Basel)       Date:  2019-11-27       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.