Literature DB >> 23512256

Umesh's intubation detector (UID) for rapid and reliable identification of tracheal intubation by novices in anaesthetised, paralysed adult patients.

Goneppanavar Umesh1, Thomas Joseph Tim, Manjunath Prabhu, Krishnamurthy N Prasad, Kaur Jasvinder.   

Abstract

Oesophageal intubation can lead to life threatening complications if left undetected. Several devices and techniques are available to confirm tracheal intubation and for early detection of oesophageal intubation. This study was carried out to evaluate the utility of the Umesh's intubation detector device for rapid and reliable differentiation of tracheal from oesophageal intubation by novice users. In this prospective, double blind and randomised study, 100 healthy patients undergoing general anaesthesia with endotracheal intubation received two identical size endotracheal tubes; one inserted into trachea and the other into the oesophagus. The Umesh's intubation detector was connected to one of the tubes randomly and a novice was asked to observe for inflation of the reservoir bag of the device while two chest compressions of approximately one inch each were given to the patient. Out of the total 100 tracheal intubations, 96 were correctly identified while the observers could not clearly conclude whether the tube was in trachea or oesophagus in the other four patients. Out of the total 100 oesophageal intubations, 99 were correctly identified. There were no complications related to the study. Umesh's intubation detector device can be used by novices for rapid and reliable differentiation of tracheal from oesophageal intubation in healthy adult patients.

Entities:  

Mesh:

Year:  2013        PMID: 23512256     DOI: 10.1007/s10877-013-9455-4

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  17 in total

1.  Capnography and the differentiation between tracheal and oesophageal intubation.

Authors:  O Sanehi; I Calder
Journal:  Anaesthesia       Date:  1999-06       Impact factor: 6.955

2.  The simplest device for confirmation of tracheal intubation.

Authors:  Goneppanavar Umesh
Journal:  Resuscitation       Date:  2011-12-21       Impact factor: 5.262

3.  Continuous end-tidal carbon dioxide monitoring for confirmation of endotracheal tube placement is neither widely available nor consistently applied by emergency physicians.

Authors:  N M Deiorio
Journal:  Emerg Med J       Date:  2005-07       Impact factor: 2.740

4.  Delayed recognition of esophageal intubation.

Authors:  Kenneth C Dittrich
Journal:  CJEM       Date:  2002-01       Impact factor: 2.410

5.  Validation of the new intubation detector device: a manikin study.

Authors:  Goneppanavar Umesh; Kaur Jasvinder; Thomas Joseph Tim
Journal:  J Clin Monit Comput       Date:  2012-05-13       Impact factor: 2.502

Review 6.  Confirmation of endotracheal tube position: a narrative review.

Authors:  Praveen Rudraraju; Lewis Ari Eisen
Journal:  J Intensive Care Med       Date:  2009-08-03       Impact factor: 3.510

7.  Efficacy of the self-inflating bulb in differentiating esophageal from tracheal intubation in the parturient undergoing cesarean section.

Authors:  A Baraka; P J Khoury; S S Siddik; M R Salem; N J Joseph
Journal:  Anesth Analg       Date:  1997-03       Impact factor: 5.108

Review 8.  Esophageal intubation: a review of detection techniques.

Authors:  P K Birmingham; F W Cheney; R J Ward
Journal:  Anesth Analg       Date:  1986-08       Impact factor: 5.108

9.  End-tidal carbon dioxide concentration during cardiopulmonary resuscitation.

Authors:  J L Falk; E C Rackow; M H Weil
Journal:  N Engl J Med       Date:  1988-03-10       Impact factor: 91.245

10.  Capnography alone is imperfect for endotracheal tube placement confirmation during emergency intubation.

Authors:  J Li
Journal:  J Emerg Med       Date:  2001-04       Impact factor: 1.484

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.