Literature DB >> 23511990

Feasibility study of needle placement in percutaneous vertebroplasty: cone-beam computed tomography guidance versus conventional fluoroscopy.

Sicco J Braak1, Kirsten Zuurmond, Hans C J Aerts, Marc van Leersum, Timotheus T Th Overtoom, Johannes P M van Heesewijk, Marco J L van Strijen.   

Abstract

OBJECTIVE: To investigate the accuracy, procedure time, fluoroscopy time, and dose area product (DAP) of needle placement during percutaneous vertebroplasty (PVP) using cone-beam computed tomography (CBCT) guidance versus fluoroscopy.
MATERIALS AND METHODS: On 4 spine phantoms with 11 vertebrae (Th7-L5), 4 interventional radiologists (2 experienced with CBCT guidance and two inexperienced) punctured all vertebrae in a bipedicular fashion. Each side was randomization to either CBCT guidance or fluoroscopy. CBCT guidance is a sophisticated needle guidance technique using CBCT, navigation software, and real-time fluoroscopy. The placement of the needle had to be to a specific target point. After the procedure, CBCT was performed to determine the accuracy, procedure time, fluoroscopy time, and DAP. Analysis of the difference between methods and experience level was performed.
RESULTS: Mean accuracy using CBCT guidance (2.61 mm) was significantly better compared with fluoroscopy (5.86 mm) (p < 0.0001). Procedure time was in favor of fluoroscopy (7.39 vs. 10.13 min; p = 0.001). Fluoroscopy time during CBCT guidance was lower, but this difference is not significant (71.3 vs. 95.8 s; p = 0.056). DAP values for CBCT guidance and fluoroscopy were 514 and 174 mGy cm(2), respectively (p < 0.0001). There was a significant difference in favor of experienced CBCT guidance users regarding accuracy for both methods, procedure time of CBCT guidance, and added DAP values for fluoroscopy.
CONCLUSION: CBCT guidance allows users to perform PVP more accurately at the cost of higher patient dose and longer procedure time. Because procedural complications (e.g., cement leakage) are related to the accuracy of the needle placement, improvements in accuracy are clinically relevant. Training in CBCT guidance is essential to achieve greater accuracy and decrease procedure time/dose values.

Entities:  

Mesh:

Year:  2013        PMID: 23511990     DOI: 10.1007/s00270-013-0598-y

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  9 in total

1.  Computer-Assisted Orthopedic and Trauma Surgery.

Authors:  Timo Stübig; Henning Windhagen; Christian Krettek; Max Ettinger
Journal:  Dtsch Arztebl Int       Date:  2020-11-20       Impact factor: 5.594

Review 2.  [Vertebroplasty and kyphoplasty : A critical statement].

Authors:  Sönke Langner; Christian Henker
Journal:  Radiologe       Date:  2020-02       Impact factor: 0.635

3.  The use of cone beam CT in achieving unipedicular spinal augmentation.

Authors:  Terrence C H Hui; Gideon Z L Tan; Alvin K W Tan; Uei Pua
Journal:  Br J Radiol       Date:  2016-07-04       Impact factor: 3.039

4.  Usefulness of intra-procedural cone-beam computed tomography in modified balloon-occluded retrograde transvenous obliteration of gastric varices.

Authors:  Edward Wolfgang Lee; Naomi So; Ryan Chapman; Justin P McWilliams; Christopher T Loh; Ronald W Busuttil; Stephen T Kee
Journal:  World J Radiol       Date:  2016-04-28

5.  Precise puncture combined with simplified percutaneous vertebroplasty to treat osteoporotic vertebral compression fractures: a comparative analysis with conventional percutaneous vertebroplasty.

Authors:  Jutao Pang; Bin Liu; Hong Chen; Wei Zhang; Jianhua Sun; Xinhu Zhang
Journal:  Am J Transl Res       Date:  2021-12-15       Impact factor: 4.060

6.  Economics of image guidance and navigation in spine surgery.

Authors:  Lutfi Al-Khouja; Faris Shweikeh; Robert Pashman; J Patrick Johnson; Terrence T Kim; Doniel Drazin
Journal:  Surg Neurol Int       Date:  2015-06-25

7.  Intraoperative 3D imaging with cone-beam computed tomography leads to revision of pedicle screws in dorsal instrumentation: a retrospective analysis.

Authors:  Felix Zimmermann; Katharina Kohl; Maxim Privalov; Jochen Franke; Sven Y Vetter
Journal:  J Orthop Surg Res       Date:  2021-12-04       Impact factor: 2.359

8.  Laser-guided cervical selective nerve root block with the Dyna-CT: initial experience of three-dimensional puncture planning with an ex-vivo model.

Authors:  Miriam I E Freundt; Manuel Ritter; Mansour Al-Zghloul; Christoph Groden; Hans U Kerl
Journal:  PLoS One       Date:  2013-07-19       Impact factor: 3.240

9.  Surgical Navigation Technology Based on Augmented Reality and Integrated 3D Intraoperative Imaging: A Spine Cadaveric Feasibility and Accuracy Study.

Authors:  Adrian Elmi-Terander; Halldor Skulason; Michael Söderman; John Racadio; Robert Homan; Drazenko Babic; Nijs van der Vaart; Rami Nachabe
Journal:  Spine (Phila Pa 1976)       Date:  2016-11-01       Impact factor: 3.241

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.