Ultrasound measures of the lumbar multifidus: effect of task and transducer position on reliability.

Christian Larivière1, Dany Gagnon, Eros De Oliveira, Sharon M Henry, Hakim Mecheri, Jean-Pierre Dumas.   

Abstract

OBJECTIVE: To (1) assess the intra- and inter-rater reliability of different ultrasound (US) measures of the lumbar multifidus muscle in subjects with and without chronic low back pain and (2) test 3 different ways to enhance reliability, that is, by testing different tasks, using a template, and averaging trials within or between days.
DESIGN: Cross-sectional repeated-measures design.
SETTING: Laboratory setting. PATIENTS: Fifteen subjects with chronic low back pain and 15 control subjects.
METHODS: Subjects (n = 30) performed contralateral arm lifting and contralateral leg lifting while in the prone position. Two 7-second videos of the lumbar multifidus (from rest to contraction) were collected with and without a template (transparency) to reposition the transducer on the skin. One of the two raters repeated the testing 7 to 14 days later to assess intrarater reliability in addition to inter-rater reliability. Reliability was assessed with the generalizability theory as a framework. MAIN OUTCOME MEASUREMENTS: US imaging measures of the lumbar multifidus thickness were obtained in patients at rest and during standardized contractions (hereafter called primary measures) at 2 vertebral levels and on both sides. These primary measures were used to calculate different, potentially useful US parameters (hereafter called derived measures).
RESULTS: Intrarater reliability was better than inter-rater reliability, and primary measures were more reliable than derived measures. The tasks investigated showed comparable reliability results, and the use of the transducer position template was not effective to increase reliability. Averaging the measures of 3 images increased reliability substantially.
CONCLUSIONS: Optimal reliability requires the use of a single rater and the averaging of at least 3 images per visit. In these conditions, primary measures reach acceptable levels of reliability, which was more difficult to achieve for most derived measures. Arm or leg lifting tasks showed similar reliability, and thus the arm-lifting task is recommended for comparisons with previous studies. The use of a transducer position template is not recommended.
Copyright © 2013 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23507347     DOI: 10.1016/j.pmrj.2013.03.010

Source DB:  PubMed          Journal:  PM R        ISSN: 1934-1482            Impact factor:   2.298


  9 in total

1.  The effect of phasic versus combined neuromuscular electrical stimulation using the StimaWELL 120MTRS system on multifidus muscle morphology and function in patients with chronic low back pain: a randomized controlled trial protocol.

Authors:  Maryse Fortin; Daniel Wolfe; Geoffrey Dover; Mathieu Boily
Journal:  BMC Musculoskelet Disord       Date:  2022-07-01       Impact factor: 2.562

2.  Reliability of lumbar multifidus and iliocostalis lumborum thickness and echogenicity measurements using ultrasound imaging.

Authors:  Joshua Farragher; Adrian Pranata; Doa El-Ansary; Selina Parry; Gavin Williams; Colin Royse; Alistair Royse; Molly O'Donohue; Adam Bryant
Journal:  Australas J Ultrasound Med       Date:  2021-06-23

3.  Lumbar Multifidus Muscle Characteristics, Body Composition, and Injury in University Rugby Players.

Authors:  Jérome Lévesque; Hassan Rivaz; Amanda Rizk; Stephane Frenette; Mathieu Boily; Maryse Fortin
Journal:  J Athl Train       Date:  2020-10-01       Impact factor: 2.860

4.  The effects of combined motor control and isolated extensor strengthening versus general exercise on paraspinal muscle morphology and function in patients with chronic low back pain: a randomised controlled trial protocol.

Authors:  Maryse Fortin; Meaghan Rye; Alexa Roussac; Neda Naghdi; Luciana Gazzi Macedo; Geoffrey Dover; James M Elliott; Richard DeMont; Michael H Weber; Véronique Pepin
Journal:  BMC Musculoskelet Disord       Date:  2021-05-22       Impact factor: 2.362

5.  Reliability of diagnostic ultrasound in measuring the multifidus muscle.

Authors:  Eirik Johan Skeie; Jan Arve Borge; Charlotte Leboeuf-Yde; Jenni Bolton; Niels Wedderkopp
Journal:  Chiropr Man Therap       Date:  2015-04-15

Review 6.  Inconsistent descriptions of lumbar multifidus morphology: A scoping review.

Authors:  Anke Hofste; Remko Soer; Hermie J Hermens; Heiko Wagner; Frits G J Oosterveld; André P Wolff; Gerbrand J Groen
Journal:  BMC Musculoskelet Disord       Date:  2020-05-19       Impact factor: 2.362

7.  The effect of low back pain and lower limb injury on lumbar multifidus muscle morphology and function in university soccer players.

Authors:  Neil Nandlall; Hassan Rivaz; Amanda Rizk; Stephane Frenette; Mathieu Boily; Maryse Fortin
Journal:  BMC Musculoskelet Disord       Date:  2020-02-12       Impact factor: 2.362

8.  Accuracy of long head of the biceps tendon palpation by physical therapists; an ultrasonographic study.

Authors:  Amy W McDevitt; Joshua A Cleland; Colin Strickland; Paul Mintken; Mary Becky Leibold; Maria Borg; Rebecca Altic; Suzanne Snodgrass
Journal:  J Phys Ther Sci       Date:  2020-11-11

9.  Quantitative ultrasound imaging of Achilles tendon integrity in symptomatic and asymptomatic individuals: reliability and minimal detectable change.

Authors:  Marie-Josée Nadeau; Amélie Desrochers; Martin Lamontagne; Christian Larivière; Dany H Gagnon
Journal:  J Foot Ankle Res       Date:  2016-08-17       Impact factor: 2.303

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.