Myelin basic protein immunosensor for multiple sclerosis detection based upon label-free electrochemical impedance spectroscopy.

Burak Derkus1, Emel Emregul, Canan Yucesan, Kaan Cebesoy Emregul.   

Abstract

A novel highly sensitive impedimetric Myelin Basic Protein (MBP) immunosensor for the determination of a Multiple Sclerosis (MS) autoantibody, Anti-Myelin Basic Protein (Anti-MBP) was developed by immobilization of MBP on Gelatin and Gelatin-Titanium Dioxide (TiO₂) modified platinium electrode. Cyclic voltammetric (CV) and Electrochemical Impedance Spectroscopic (EIS) methods were employed in determination of the electrode responses and applicability. Gelatin-MBP and gelatin-TiO₂-MBP electrodes were prepared by chemical immobilization of the substrates onto the platinium electrodes. The formal potentials of MBP confined on gelatin-MBP and gelatin-TiO₂-MBP surfaces are estimated to be 195 and 205 mV, respectively. Thus, a little more reversible electron transfer reaction occurs on the gelatin-TiO₂-MBP immunosensor surface. The peak separations of MBP (150 mV and 110 mV s(-1) at 100 mV s(-1)) and the asymmetric anodic and cathodic peak currents indicate that the electron transfer between Anti-MBP and gelatin-MBP/gelatin-TiO₂-MBP immunosensor is quasireversible. Control samples containing a nonspecific human immunoglobulin G (hIgG) antibody were also studied, and calibration curves were obtained by subtraction of the responses for specific and nonspecific antibody-based sensors. Gelatin-MBP and gelatin-TiO₂-MBP immunosensors have detection limit of 0.1528 ng ml(-1) and 0.1495 ng ml(-1) respectively. This immunosensor exhibits high sensitivity and low response times (58 s for gelatin-MBP and 46 s for gelatin-TiO₂-MBP immunosensor). The developed label-free impedimetric immunosensors also provide a simple and sensitive detection method for the specific determination of Anti-MBP in human cerebrospinal fluid (CSF) and serum samples.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23500477     DOI: 10.1016/j.bios.2013.01.060

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  11 in total

1.  An impedimetric bioaffinity sensing chip integrated with the long-range DC-biased AC electrokinetic centripetal vortex produced in a high conductivity solution.

Authors:  Ming-Jie Lin; Yen-Fu Liu; Ching-Chou Wu
Journal:  Biomicrofluidics       Date:  2018-07-06       Impact factor: 2.800

Review 2.  Biosensors and nanobiosensors for rapid detection of autoimmune diseases: a review.

Authors:  Farzaneh Ghorbani; Hossein Abbaszadeh; Amir Mehdizadeh; Majid Ebrahimi-Warkiani; Mohammad-Reza Rashidi; Mehdi Yousefi
Journal:  Mikrochim Acta       Date:  2019-11-23       Impact factor: 5.833

Review 3.  Blood Trace Element Status in Multiple Sclerosis: a Systematic Review and Meta-analysis.

Authors:  Elahe Nirooei; Seyyed Mohammad Amin Kashani; Soroor Owrangi; Fatemeh Malekpour; Maryam Niknam; Fatemeh Moazzen; Peyman Nowrouzi-Sohrabi; Somaye Farzinmehr; Hamed Akbari
Journal:  Biol Trace Elem Res       Date:  2021-02-21       Impact factor: 3.738

4.  Label-Free and Regenerative Electrochemical Microfluidic Biosensors for Continual Monitoring of Cell Secretomes.

Authors:  Su Ryon Shin; Tugba Kilic; Yu Shrike Zhang; Huseyin Avci; Ning Hu; Duckjin Kim; Cristina Branco; Julio Aleman; Solange Massa; Antonia Silvestri; Jian Kang; Anna Desalvo; Mohammed Abdullah Hussaini; Su-Kyoung Chae; Alessandro Polini; Nupura Bhise; Mohammad Asif Hussain; HeaYeon Lee; Mehmet R Dokmeci; Ali Khademhosseini
Journal:  Adv Sci (Weinh)       Date:  2017-03-06       Impact factor: 16.806

Review 5.  Construction and Potential Applications of Biosensors for Proteins in Clinical Laboratory Diagnosis.

Authors:  Xuan Liu; Hui Jiang
Journal:  Sensors (Basel)       Date:  2017-12-04       Impact factor: 3.576

Review 6.  Electrochemical Biosensors as Potential Diagnostic Devices for Autoimmune Diseases.

Authors:  Anca Florea; Gheorghe Melinte; Ioan Simon; Cecilia Cristea
Journal:  Biosensors (Basel)       Date:  2019-03-04

7.  Electrochemical Detection of Plasma Immunoglobulin as a Biomarker for Alzheimer's Disease.

Authors:  Goulielmos-Zois Garyfallou; Orlando Ketebu; Samet Şahin; Elizabeta B Mukaetova-Ladinska; Michael Catt; Eileen Hao Yu
Journal:  Sensors (Basel)       Date:  2017-10-27       Impact factor: 3.576

Review 8.  Emerging Biosensing Technologies for Neuroinflammatory and Neurodegenerative Disease Diagnostics.

Authors:  Catarina M Abreu; Ricardo Soares-Dos-Reis; Pedro N Melo; João B Relvas; Joana Guimarães; Maria José Sá; Andrea P Cruz; Inês Mendes Pinto
Journal:  Front Mol Neurosci       Date:  2018-05-16       Impact factor: 5.639

Review 9.  Gold Nanoparticles: Multifaceted Roles in the Management of Autoimmune Disorders.

Authors:  Khadijeh Koushki; Sanaz Keshavarz Shahbaz; Mohsen Keshavarz; Evgeny E Bezsonov; Thozhukat Sathyapalan; Amirhossein Sahebkar
Journal:  Biomolecules       Date:  2021-08-30

Review 10.  An Update on the Laboratory Diagnosis of Neuromyelitis Optica Spectrum Disorders.

Authors:  Mani Vimalin Jeyalatha; Kulandai Lily Therese; Appakkudal Ramaswamy Anand
Journal:  J Clin Neurol       Date:  2022-03       Impact factor: 3.077

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.