Literature DB >> 23499962

UPLC-MS/MS analysis of C5-acylcarnitines in dried blood spots.

Nils Janzen1, Ulrike Steuerwald, Stefanie Sander, Michael Terhardt, Michael Peter, Johannes Sander.   

Abstract

BACKGROUND: Metabolic screening including newborn screening requires further differentiation of C5-acylcarnitines in order to separate different metabolic disorders and to detect interferents like pivalic acid originating from antibiotics.
METHODS: For individual quantification of C5-acylcarnitine isoforms in dried blood spots we combined UPLC using a C18 column and gradient elution with tandem mass spectrometry in ESI+mode.
RESULTS: Results were linear, coefficients of determination (R(2))>0.9977, intra- and inter-assay coefficients of variations <5.2%, recovery 96.8-105.2%, limits of detection and quantitation <0.2 μmol/L. Out of 29.309 blood samples of the isolated population of the Faroe Islands 56 exceeded the cut-off of 0.5 μmol/L for C5-acylcarnitine; 45 of which could be retested using the method described. Pivaloylcarnitine was identified in 43 samples, isovalerylcarnitine was found in two samples.
CONCLUSIONS: The method was developed to allow direct re-analysis of samples showing elevated concentrations of C5-acylcarnitines in a metabolic screening program based on quantification of acylcarnitines after butylation. The technique should be especially useful in newborn screening for exclusion of false positives and for differentiation between isovaleric acidemia and 2-methylbutyryl-CoA dehydrogenase deficiency.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23499962     DOI: 10.1016/j.cca.2013.03.001

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  4 in total

1.  Application of a second-tier newborn screening assay for c5 isoforms.

Authors:  T Cloppenborg; N Janzen; Hj Wagner; U Steuerwald; M Peter; Am Das
Journal:  JIMD Rep       Date:  2013-11-06

2.  A Simple Flow Injection Analysis-Tandem Mass Spectrometry Method to Reduce False Positives of C5-Acylcarnitines Due to Pivaloylcarnitine Using Reference Ions.

Authors:  Takanari Hattori; Yoshitomo Notsu; Misa Tanaka; Miki Matsui; Tetsuo Iida; Jun Watanabe; Yoshimitsu Osawa; Seiji Yamaguchi; Shozo Yano; Takeshi Taketani; Hironori Kobayashi
Journal:  Children (Basel)       Date:  2022-05-10

Review 3.  Screening newborns for metabolic disorders based on targeted metabolomics using tandem mass spectrometry.

Authors:  Hye-Ran Yoon
Journal:  Ann Pediatr Endocrinol Metab       Date:  2015-09-30

4.  Expanded Screening of One Million Swedish Babies with R4S and CLIR for Post-Analytical Evaluation of Data.

Authors:  Lene Sörensen; Ulrika von Döbeln; Henrik Åhlman; Annika Ohlsson; Martin Engvall; Karin Naess; Carolina Backman-Johansson; Yvonne Nordqvist; Anna Wedell; Rolf H Zetterström
Journal:  Int J Neonatal Screen       Date:  2020-05-27
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.