Literature DB >> 23499067

Anterior segment variations after posterior chamber phakic intraocular lens implantation in myopic eyes.

Haotian Lin1, Pisong Yan, Keming Yu, Lixia Luo, Jingjing Chen, Zhuoling Lin, Weirong Chen.   

Abstract

PURPOSE: To evaluate anterior segment variations after posterior chamber phakic intraocular lens (pIOL) implantation in myopic eyes.
SETTING: Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China.
DESIGN: Cohort study.
METHODS: Patients with high myopia were scheduled for nontoric Implantable Collamer Lens pIOL or toric Implantable Collamer Lens pIOL implantation. Anterior segment optical coherence tomography was performed to evaluate the anterior segment variations over time and the impact of physiologic accommodation and change in brightness after pIOL implantation. Slitlamp photography of the anterior segment was taken after pupil dilation to calculate pIOL rotation.
RESULTS: There was significantly improved visual acuity and refractive status after implantation of both pIOLs. Anterior segment axial variations had good stability 6 months postoperatively. However, nontoric pIOL rotation occurred in 1 eye 7 months postoperatively and rotation of the toric pIOL occurred in 2 eyes at 3 months and 6 months. Stimulations of -4.0 diopters (D) and -8.0 D led to significant changes in anterior chamber depth (ACD) based on the lens (ACD-lens), ACD after pIOL implantation, distance between the pIOL posterior surface and the lens anterior surface (pIOL-lens), and pupil diameter. Increasing ambient light brightness could reduce the ACD-lens and pIOL-lens.
CONCLUSIONS: Both pIOLs had good axial stability in myopic eyes 6 months postoperatively; however, rotational stability over time could not be determined. The physiologic adjustment and change in brightness could influence the anterior segment significantly in eyes with a pIOL.
Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23499067     DOI: 10.1016/j.jcrs.2012.12.026

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  5 in total

1.  Prevalence of Corneal Astigmatism and Anterior Segmental Biometry Characteristics Before Surgery in Chinese Congenital Cataract Patients.

Authors:  Duoru Lin; Jingjing Chen; Zhenzhen Liu; Xiaohang Wu; Erping Long; Lixia Luo; Zhuoling Lin; Xiaoyan Li; Li Zhang; Hui Chen; Jinchao Liu; Weirong Chen; Haotian Lin; Yizhi Liu
Journal:  Sci Rep       Date:  2016-02-25       Impact factor: 4.379

2.  Buffering zone of implantable Collamer lens sizing in V4c.

Authors:  Seung Wan Nam; Dong Hui Lim; Joo Hyun; Eui-Sang Chung; Tae-Young Chung
Journal:  BMC Ophthalmol       Date:  2017-12-22       Impact factor: 2.209

3.  Dynamic Assessment of Light-Induced Vaulting Changes of Implantable Collamer Lens With Central Port by Swept-Source OCT: Pilot Study.

Authors:  Felix Gonzalez-Lopez; Blas Mompean; Rafael Bilbao-Calabuig; Jorge Vila-Arteaga; Jaime Beltran; Julio Baviera
Journal:  Transl Vis Sci Technol       Date:  2018-05-01       Impact factor: 3.283

4.  Off-Label Use of Phakic Intraocular Lens with a "Piggyback" Technique.

Authors:  Tadgh Schempf; Hoon C Jung
Journal:  Case Rep Ophthalmol       Date:  2018-11-21

5.  Bilateral Toric Phakic Intraocular Lens Implantation for Correction of High Myopic Astigmatism in a Patient with Marfan Syndrome with Lens Coloboma: A Case Report.

Authors:  Bhupesh Singh; Sourabh Sharma; Suchit Dadia; Neha Bharti; Sudhank Bharti
Journal:  Case Rep Ophthalmol       Date:  2021-04-12
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.